![Astria Fireplaces F0703 Installation And Operation Instructions Manual Download Page 4](http://html1.mh-extra.com/html/astria-fireplaces/f0703/f0703_installation-and-operation-instructions-manual_2990889004.webp)
Astria.us.com
126653-01_E
4
PRODUCT DIMENSIONS
Creosote – Formation and Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture
to form creosote. The creosote vapors condense in
the relatively cool chimney flue of a slow-burning
fire. As a result, creosote residue accumulates on
the flue lining. When ignited this creosote makes an
extremely hot fire.
The chimney shall be inspected at least twice a
year during the heating season to determine when a
creosote buildup has occurred. When creosote has
accumulated (1/8" [3 mm] or more) it shall be removed
to reduce the risk of a chimney fire.
SAFETY
Continued
Figure 1 - Dimensions
WARNING: Always leave glass doors fully opened
or fully closed when operating fireplace.
WARNING: Children and adults should be alerted
to the hazards of high surface temperatures and to
stay away to avoid burns or clothing ignition. Young
children should be carefully supervised when in the
same room as fireplace.
LEFT SIDE
VIEW
FRONT VIEW
TOP VIEW
36-1/2”
20-1/2”
54"
24"
21-3/8”
42-5/8”
9-1/2”
19"
4-1/2”
12"
7"
12"
11-1/4”
10-1/4”
6"
37-1/2”
15”
(381 mm)
O.D.
OUTSIDE AIR
GAS LINE
16"
(407 mm)
1-1/2”
(38 mm)
2-1/2”
12-3/8”
(315 mm)
15-1/2”
CONDUIT
(610 mm)
24"
(610 mm)
(153 mm)
(64 mm)
(242 mm)
(1083 mm)
(543 mm)
(394 mm)
(1372 mm)
(521 mm)
(927 mm)
(953 mm)
(483 mm)
(115 mm)
(286 mm)
(305 mm)
(178 mm)
(261 mm)
(305 mm)
MODEL
CATALOG NO.
Windsor STP2
F0703