Astria Fireplaces Blackstone Series Installation And Operation Instructions Manual Download Page 15

Astria.us.com

901046-00NC

15

OPERATION AND MAINTENANCE  

Continued

Figure 26 - Locating Access Cover Plate

LOCATING ACCESS COVER PLATE

Sheet metal cover plates located underneath front hearth refractory may 

have shifted or moved out of place while fireplace was in transit. These 

cover plates must be kept in the proper location prior to using the fireplace 

(See Figure 26). 
For further operating guidelines, instructions and warranty informa-

tion, please refer to your homeowner's guide or contact your dealer.

REPLACEMENT PARTS

See Pages 16 to 17 for a complete replacement parts list. Use only 

parts supplied from the manufacturer.
Normally, all parts should be ordered through your IHP distributor 

or dealer. Parts will be shipped at prevailing prices at time of order.
When ordering repair parts, always give the following information:
1. The model number of the fireplace.

2. The serial number of the fireplace.

3. The part number.

4. The description of the part.

5. The quantity required.

6. The installation date of the fireplace.
If you encounter any problems or have any questions concerning the 

installation or application of this fireplace, please contact your dealer.

IHP

1769 East Lawrence Street

Russellville, AL 35654

Visit us at Astria.us.com

TECHNICAL SERVICE

You may have further questions about installation, operation, or 

troubleshooting. Please contact your IHP dealer for any questions 

or concerns. When contacting your dealer please have your model 

and serial numbers of your fireplace ready. You can also visit our 

web site at Astria.us.com.

Access 

Panel

IMPORTANT NOTICE

A manufactured shroud which has been approved by a 

national testing agency for use with this fireplace may 

be used if installed in accordance with the instructions 

by its manufacturer. A locally fabricated shroud may be 

used with IHP Shroud Leg Spacer Kit (SLK) in accor-

dance with instructions provided with the shroud.

NOTICE: The firebox canopy (hood) must not be modified 

or replaced with a canopy that may be provided with the 

unvented decorative room heater.

CAUTION: THE STRUCTURAL INTEGRITY OF THE MANU-

FACTURED HOME FLOOR, WALL, AND CEILING/ROOF 

MUST BE MAINTAINED.

 

 

WARNING: DO NOT INSTALL IN SLEEPING ROOM OF 

MOBILE HOMES.

Canadian code CAN/ULC-S610-M87 and other pertinent codes require stain-

less steel chimney for the installation of this fireplace. A Cold Air Climate 

Kit is also required in Canada and is recommended for cooler regions in the 

United States. Below, find a list of approved stainless steel parts.

Chimney Parts List for Canada

Catalog 

No.

Model No. 8" Hi-Temp  

Wood burning Chimney

F0881

12-8HT

12" Section Hi-Temp Double Wall Pipe Snap Lock

F0882

18-8HT

18" Section Hi-Temp Double Wall Pipe Snap Lock

F0883

24-8HT

24" Section Hi-Temp Double Wall Pipe Snap Lock

F0884

36-8HT

36" Section Hi-Temp Double Wall Pipe Snap Lock

F0885

48-8HT

48" Section Hi-Temp Double Wall Pipe Snap Lock

F0886

30E-8HT

30 Degree Hi-Temp Offset and Return

F0887

12S-8HT

Hi-Temp Chimney Support (For Use With Chimney 

Heights In Excess of 30')

F0888

RT-8HT

Hi-Temp Round Top with Mesh Screen

F0889

RTT-8HT*

Hi-Temp Round Top with Mesh Screen and Slip 

Section

F0890

RLT-8HT

Hi-Temp Round Top with Louvered Screen

F0891

RLTT-8HT* Hi-Temp Round Top with Louvered Screen and 

Slip Section

F0892

ET-8HT*

Hi-Temp Pyramid Top with Slip Section

F0893

ETL-8HT*

Hi-Temp Large Pyramid Top with Slip Section (use 

with all 8" systems)

F0894

AP-8HT

Hi-Temp Anchor Plate/Collar Assembly (for ma-

sonry fireplaces)

F0929

CAK-8

Cold Air Collar Kit - 8" Chimney

*When ordered alone, this part cannot ship via parcel delivery services.

IMPORTANT NOTICES - CANADA

Summary of Contents for Blackstone Series

Page 1: ...iction such as the municipal building department fire department etc should be contacted before installation to determine the need to obtain a permit POUR LE CANADA L autorit comp tente comme le servi...

Page 2: ...red or approved by IHP in combination with an IHP fireplace system Proper installation is the most important step in ensuring safe and continuous operation of the fireplace Consult the local building...

Page 3: ...gnificanthazard IMPORTANT See appendix A page 21 for additional information regarding draft requirements smoking causes and troubleshooting WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CAR...

Page 4: ...RD NOT LESS THAN 12 305 mm TO PERPENDICULAR SIDEWALL 0 0 MM TO BOTTOM 12 305 mm EACH SIDE GAS LINE KNOCK OUT GAS LINE KNOCK OUT RIGHT SIDE LEFT SIDE AIR KIT KNOCK OUT 8 1 4 210 mm 8 1 4 210 mm 25 3 8...

Page 5: ...langes touch side framing 4 Check level of fireplace and shim with sheet metal if necessary 5 Before securing fireplace to prepared framing ember protector must be placed between hearth extension not...

Page 6: ...ening of fireplace NFPA 211 Section Clearance from Combustible Material Mantels or any other combustible material may come up to side edge of black metal face of fireplace if projection from front fac...

Page 7: ...ugh a sidewall AK4 See Figure 7 for instruction of operating air kit CAUTION Combustion air inlet ducts shall not terminate in attic space The maximum height for the air vent can not exceed 3 feet bel...

Page 8: ...20 feet must be supported USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart page 9 and Figure 9 pag...

Page 9: ...turn Elbow Return Elbow Return Elbow Return Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow Offset Elbow 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m 6 Max 1 83 m Ceiling...

Page 10: ...oof Pitchisthedistancetheroofdrops overagivenspan usually12 A6 12pitchmeansthattheroofdrops 6 for each 12 measure horizontally down from roof rafters 3 Use roof opening chart Figure 14 page 11 to dete...

Page 11: ...ireplace system must be terminated with listed round top or chase terminations In any case refer to installation instructions supplied with termination Terminations approved for this fireplace are RT...

Page 12: ...d is to be installed contact manufacturer for specifications Figure 18 Multiple Chase Installation 10 3 05 m 10 3 05 m 2 0 61 m Min 2 0 61 m Min 3 0 92 m Min 3 0 92 m Min Level of Flue Gas Outlet Figu...

Page 13: ...desired CAUTION All gas piping and connections must be tested for leaks after installation is completed After ensuring that gas valve is on apply soap and water solution to all connections and joints...

Page 14: ...ce with glass doors has a limited amount of air for combustion Excessive heat within fireplace can result if too large a fire is built or if combustion air gate is not completely open The following ti...

Page 15: ...in accordance with the instructions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accor dance with instructions provided with the shroud NOTICE The...

Page 16: ...1046 00NC 16 11 27 23 23 22 24 10 14 25 4 17 3 2 1 18 5 20 28 12 7 15 9 16 13 8 26 6 19 21 PARTS WOOD BURNING FIREPLACE MODELS Blackstone42RWS Blackstone42LWS MODEL CAT NO Blackstone42RWS F2539 Blacks...

Page 17: ...9 Wrapper Bottom 1 10 Front Face Weldment Smooth 1 Front Face Weldment Louvered 1 11 See Page 18 Left Side Brick Liner 1 12 See Page 18 Rear Brick Liner 1 13 See Page 18 Right Side Brick Liner 1 14 S...

Page 18: ...n any of these parts Never use substitute materials not ap proved by IHP Use of non approved parts can result in poor performance and safety hazards 1 2 4 3 6 5 REFRACTORY STAIN KITS Use the refractor...

Page 19: ...Section Hi Temp Double Wall Pipe Snap Lock F0884 36 8HT 36 Section Hi Temp Double Wall Pipe Snap Lock F0885 48 8HT 48 Section Hi Temp Double Wall Pipe Snap Lock 30 OFFSET AND RETURN F0900 30E 8DM 30 D...

Page 20: ...AND SLIP SECTION F0921 ETL 8DM Square Top with Slip Section F0893 ETL 8HT Hi Temp Large Pyramid Top with Slip Section MESH SQUARE TOP TERMINATION F0922 ETO 8DM Square Top with Mesh MESH SQUARE TOP TER...

Page 21: ...ns inadequate chimney heights adversewindconditionsand orunusualenvironmental factors or conditions beyond our control take into account all variables within the installation and install the appliance...

Page 22: ...he best location to install your appliance is determined by consid ering the location of windows doors and the traffic flow in the room where the appliance is located allowing space in front of the un...

Page 23: ...r propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperature...

Page 24: ...0 Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...

Reviews: