Astria Fireplaces Aries 33 Series Manual Download Page 71

71

Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900199-00, Rev. C  02/2018

Innovative Hearth Products
1769 East Lawrence Street • Russellville, AL 35654

Innovative Hearth Products

Astria

®

 Brand Gas Fireplace

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria

®

 brand gas fireplace ("Product") to be free from defects in materials and workmanship 

at the time of manufacture. The product body, firebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal 
breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty 
period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not 
commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor 
rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 
Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT  DATE

Warranty coverage begins on the date of purchase.  In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer/distributor,  whichever occurs earlier.  The warranty shall commence no later than 24 months following 
the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 
provided.  The product body, firebox and barrier carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded 
from this Limited Lifetime Warranty.  The following do not carry the Limited Lifetime Warranty but are warranted as follows:

Burner

 – Repair or replacement for five years from the date of installation

Gas components & electrical components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Gold & nickel plating

 - Replacement for two years from date of installation. Excludes tarnishing 

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component 

Light bulbs & batteries

 – Replacement for 90 days from the date of installation

Logs

 – Replacement for five years from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors & optional glass accessories 

– Repair or replacement for 90 days from the date of installation

Optional surrounds

 – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one 

year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit

Tempered Glass

 -Replacement for one year from the date of installation

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fire hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 
which may generate negative pressure in the room in which the appliance is installed.  Additionally IHP assumes no responsibility for drafting conditions caused by venting 
configurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction,  which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from  the nearest stocking  IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 
repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 
use or purpose, and there is no implied condition of fitness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty. 

No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 
Lifetime Warranty are in addition to and not a modification  of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefits and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1769 East Lawrence Street; Russellville, AL 35654 or visit our website at WWW.ASTRIA.US.COM.

Summary of Contents for Aries 33 Series

Page 1: ...uvez rejoindre le fournisseur de gaz appelez le service des incindies L installationetl entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par le fournisseur de gaz IN...

Page 2: ...ncelles fourni avec ce foyer r duit le risque de br lure en cas de contact accidentel avec la vitre chaude et doit tre install pour la protection Des enfants et Des personnes risques Vea el volante ad...

Page 3: ...ca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio...

Page 4: ...o Combustibles 14 Wall Finishes Surrounds Mantels 15 Installation Preparation 15 Installation Installation Sequence 16 Construct the Fireplace Framing 16 Prepare the Fireplace Top Spacers 18 Route the...

Page 5: ...des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour emp cher l acc s un foyer ou un po le...

Page 6: ...or its operating controls is dangerous Improper installation or use of this appliance can cause serious injury or death from fire burns explosion or carbon monoxide poisoning CARBON MONOXIDE POISONING...

Page 7: ...upplemental heaters Therefore it is advisable to have an alternate primary heat source when installed in a dwelling Your gas appliance is covered by a limited lifetime warranty You will find a copy of...

Page 8: ...ce be kept clean Remarqu L installation et la r paration devrait tre confi es un technicien qualifi L appareil devrait faire l objet d une inspection par un technicien professionnel avant d tre utilis...

Page 9: ...igure 2 Electronic Gas Valves Propane tanks are at pressures that will cause damage to valve components Verify that the tanks have step down regulators to reduce the pressure to safe levels The applia...

Page 10: ...setts The flexible gas line connector used shall not exceed 36 914 mm in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements In the Commonweal...

Page 11: ...the fireplace are primary concerns However vent system routing to the exterior and access to the fuel supply are also important Due to high temperatures the fireplace should be located out of traffic...

Page 12: ...um height from roof to lowest discharge opening of vent Horizontal overhang Vertical wall Vent termination Storm collar Concentric vent pipe Flashing 1 25 4 mm minimum clearance to combustibles Table...

Page 13: ...ustion air inlet to any other fireplace 6 150 mm for fireplaces 10 000 Btu h 3 kW 9 230 mm for fireplaces 10 000 Btu h 3 kW and 50 000 Btu h 15 kW 12 300 mm for fireplaces 50 000 Btu h 15 kW 6 150 mm...

Page 14: ...extending the full width and depth of the unit The fireplace may be located on or near conventional construction materials However if installed on combustible materials such as carpeting vinyl tile o...

Page 15: ...bove the fireplace opening However do not allow anything to hang below the fireplace hood Minimum clearance requirements include any projections such as shelves window sills mantels etc above the fire...

Page 16: ...Proper Fireplace Operation Page 40 Finishing 14 Optional Install the Firebox Liners Page 41 15 Traditional Fireplaces Install the Logs Volcanic Stone and Glowing Embers Page 41 16 Contemporary Firepl...

Page 17: ...do NOT apply for flexible venting When using flexible venting refer to the kit requirements for framing specifications Table 11 Fireplace Framing Specifications Corner Installation with Horizontal Ter...

Page 18: ...Line Properly size and route the gas supply line from the supply regulator to the area where the appliance is to be installed per requirements outlined in the National Fuel Gas Code NFPA 54 latest ed...

Page 19: ...33 5 Install the blower control switch according to its included instructions 6 Place the Fireplace in the Framing and Secure NOTE Nailing flanges combustible members and screw heads in areas directl...

Page 20: ...be vertical roof and horizontal exterior wall vent applications Use only approved vent components Pages 45 and 46 NOTE This fireplace must be vented directly to the outside WARNING The vent system may...

Page 21: ...zontal run 60 ft Maximum vertical run 60 1 9 25 Horizontal Distance ft Vertical Height ft Vertical Height ft 2 5 Elbow 5 10 15 Base wing Base 6 ft Minimum vertical run 6 ft Minimum vertical run U Shap...

Page 22: ...age and seal both the inner and outer vent pipe 3 If desired a 6 x 1 2 screw can be used at the joint but is not required as the pipe will securely lock when twisted Figure 17 Where required a telesco...

Page 23: ...86 15 5 0 0 0 0 4 4 196 5 16 375 0 1 0 0 4 5 207 17 25 0 0 0 6 0 6 211 5 17 625 1 0 0 6 0 7 217 5 18 125 0 1 0 6 0 7 229 5 19 125 0 0 1 6 0 7 232 5 19 375 0 0 0 0 5 5 241 5 20 125 0 0 0 7 0 7 246 20 5...

Page 24: ...fied in ANSI Z223 1 In Canada the current CAN CGA B149 1 installation code by major building codes Always consult your local codes for specific requirements A general guide to follow is the gas vent r...

Page 25: ...Install firestop spacer at ceiling When using Secure Vent use SV4 5VF firestop spacer at ceiling joists when using Secure Flex use SF4 5VF firestop spacer If there is living space above the ceiling le...

Page 26: ...and sides only and trim where necessary Seal the top and both sides of the flashing with waterproof caulking 12 Install the storm collar Install the storm collar supplied with the flashing over the v...

Page 27: ...elbow is the only vertical component in the system WARNING Do NOT join separate sections of concentric flexible vent pipe Figure 25 Top Vent Straight Table 16 Rear Vent One 90 Elbow Ceiling firestop...

Page 28: ...h more than 6 ft of vertical rise See Page 21 for more information If 25 ft of H horizontal vent run is needed then 5 ft straight section minimum of V vertical vent will be required This table shows a...

Page 29: ...minimum clearances for combustibles Page 24 2 Frame the exterior wall opening Locate the center of the vent outlet on the exterior wall Table 11 Cut and or frame an opening 10 1 2 x 12 1 8 267 x 308...

Page 30: ...h the termination to the vent section or telescoping vent section elbow or fireplace collar Figure 27 13 Install the firestop spacer at the exterior wall When using the square termination install SV4...

Page 31: ...Caulk For thicknesses greater than 9 1 4 235 mm see Table 21 Figure 28 Venting Connection and Exterior Wall Recessing of the Horizontal Compact Termination SV4 5HTKCT See Table 11 for the minimum dist...

Page 32: ...x firestop spacer must be used any time vent pipe passes through a combustible wall WARNING Do not join separate sections of concentric flexible vent together Table 21 Rear Vent No Elbows Compact term...

Page 33: ...for more information Compact termination SV4 5HTKCT shown See Table 21 as an aid in venting component selection for a particular range of exterior wall thicknesses If 25 ft of H horizontal vent run is...

Page 34: ...ex use ceiling firestop spacer SF4 5VF When using Secure Flex use wall firestop spacer SF4 5HF Wall firestop spacer SV4 5HF Ceiling firestop spacer SV4 5VF H V H1 H2 Table 27 Top Vent Three 90 Elbows...

Page 35: ...le vent then push it back out of the way b Apply a bead of Mill Pac Black 700 F high temperature sealant P N 10K81 to the inner adaptor collar approximately 1 2 from the end c Pull and extend the inne...

Page 36: ...Flex vent to Secure Flex terminations only Do NOT substitute Secure Vent terminations or Secure Vent adaptor for Secure Flex components Secure Flex termination and adaptor collars are a different cir...

Page 37: ...rol switch within the millivolt control circuit using the 15 ft of 2 conductor wire supplied with the unit Figure 31 NOTE The supplied 15 ft of 2 conductor wire has one end of each conductor connected...

Page 38: ...ail lead Figure 33 Connect the white power supply wire to the outlet s common terminal 5 Connect the ground supply wire to the pigtail lead attached to the outlet s green ground screw Restrain the inl...

Page 39: ...12 Connect the Gas Line All codes require a shutoff valve mounted in the supply line Figure 35 illustrates two methods for connecting the gas supply The flex line method is acceptable in the U S howev...

Page 40: ...me to check for leaks Turn on gas supply and test for gas leaks using a gas leak test solution also known as bubble leak solution NOTE Using a soapy water solution is an effective leak test solution b...

Page 41: ...sooting resulting from improperly setting the air shutter is not covered under the warranty The air shutter rod and nearby appliance surfaces are hot Exercise caution to avoid injury while adjusting f...

Page 42: ...hutter is open too far Flame will be blue Air shutter gap should be decreased Figure 38 Air Shutter Adjustment Rod Air Shutter Adjustment Rod Down Fully Open Position Burner Tube Adjustment Rod Up Ful...

Page 43: ...dels must have a barrier installed prior to operation 1 Open the control compartment door Page 50 2 Hold the barrier in front of the glass door and slide it up into the slots above the glass door and...

Page 44: ...llez l tiquette sur la surface de la plaque de l interrupteur mural qui contr le le foyer Figure A ou du thermostat mural Figure B Choisissez la langue qui est principalement parl e dans la r sidence...

Page 45: ...2 rigid Catalog Number Model Description The following flashing comes packaged with a storm collar 77L78 SV4 5F Flat Roof Flashing 77L79 SV4 5FA 1 12 to 7 12 Adjustable Flashing 77L80 SV4 5FB 7 12 to...

Page 46: ...4 SFKIT12SS Small Square Termination for flex with 12 305 mm of compressed flex vent see 750204M 94L05 SFKIT18SS Small Square Termination for flex with 18 457 mm of compressed flex vent see 750204M 94...

Page 47: ...l installation de cette trousse L installation n est pas ad quate ni compl te tant que le bon fonctionnement de l appareil converti n a pas t v rifi selon les instructions du fabricant fournies avec...

Page 48: ...carbon monoxide than others including pregnant women people with heart or lung disease or anemia those under the influence of alcohol and those at high altitudes NOTE Do not place furniture or other c...

Page 49: ...opera la chimenea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea...

Page 50: ...lit the fireplace main burner can be turned ON OFF using the optional switch Burn in Period The first few times this fireplace is operated there will be an odor from the curing of paint and the burni...

Page 51: ...r Continuous Pilot Ignition Switch Fireplaces with an electronic gas valve have a continuous pilot ignition CPI switch installed in the control compartment This switch allows the pilot to be switched...

Page 52: ...o these instructions improper combustion could occur This could result in the excessive production of soot and or the colorless odorless toxic gas carbon monoxide CO NOTE If applicable install the fir...

Page 53: ...brackets Figure 50 Placing log 1 and 2 3 Align the notches in the bottom of the rear log 1 with the left rear brackets Figures 47 and 48 4 Position the left rear log 1 on the left rear bracket and the...

Page 54: ...led AVERTISSEMENT Une barri re con ue pour r duire le risque de br lure par le hublot chaude est fournie avec l appareil et doit tre install WARNING The door should easily close without needing to be...

Page 55: ...y sliding in into the top channel with the flat side toward the fireplace then swinging the base of the barrier into the brackets and lowering it into place 5 Close the control compartment door Removi...

Page 56: ...ents However more frequent periodic inspections and cleanings should be performed by the homeowner NOTE Prior to the first use of the fireplace and each burn season and periodically during the burn se...

Page 57: ...e at your local IHP dealer Never attempt to paint a hot fireplace Do not attempt to repaint the fireplace until the finish is completely cured Burn in Period on Page 50 If the surface becomes stained...

Page 58: ...age 70 Cleaning the burner Carefully remove the logs media Vacuum out any foreign matter on the burner e g lint carbon etc Ensure the burner ports are free of debris NOTE Improper positioning of logs...

Page 59: ...of dislocation of the vent components Fireplace Inspection Qualified Service Technician Perform the appropriate fireplace inspection procedure detailed in this manual Replacing Glowing Embers Homeown...

Page 60: ...or fireplaces controlled thermostatically Forced Air Kits Catalog Model Description 80L84 FBK 100 Blower Standard single speed 80L85 FBK 200 Blower Variable Speed with wall mounted switch 80L86 FBK 25...

Page 61: ...4 Model WS S TSTAT ON OFF and Timer Control Kits Feature a timed ON OFF mode as well as manual ON OFF operation ON OFF and Timer Control Kits Electronic Models Cost Effective Solution Catalog Number M...

Page 62: ...ace Catalog Model 85L87 FWSK OFF ON Wall Switch Kit Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK 100 blower kit is installed Va...

Page 63: ...n released stop and immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control...

Page 64: ...nisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz 10 Tournez...

Page 65: ...ol which has been under water Electronic Gas Control Valve SIT Electronic Pilot Assembly 3 Turn off all electric power to the appliance if service is to be performed Note The control may have a batter...

Page 66: ...une batterie de secours installer les batteries au besoin 8 Placez l interrupteur du r cepteur en position REMOTE ou l interrupteur mural en position ON 9 Si applicable Appuyez sur le bouton ON OFF p...

Page 67: ...ing instructions a Defective pilot generator thermocouple Check pilot flame it must impinge on thermocouple Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the conn...

Page 68: ...as supply and gas shutoff valves b Loose wires to the valve or ignition module Check control compartment for any obviously loose wiring call a service technician if necessary c Pilot flame is not engu...

Page 69: ...11 0 F1682 Aries33RMP 88lb 11 0 F1683 Aries33REN 88lb 11 0 F1737 Aries33REP 88lb 11 0 Cat No Model Weight Cu Ft F1672 AriesCD33TMN 96 lb 11 0 F1673 AriesCD33TMP 96 lb 11 0 F1674 AriesCD33TEN 96 lb 11...

Page 70: ...1 Electronic Ground Wire H7278 1 Electronic ON OFF Switch 27K30 1 Electronic Control Module J7906 1 Millivolt Pilot Assembly Natural Gas 69L17 1 Millivolt Pilot Assembly Liquid Propane 69L18 1 9 Milli...

Page 71: ...fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal...

Page 72: ...ke changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information Printed...

Reviews: