9
10. WINTERISING:
At the end of the bathing season, it is recommended that the filter be emptied to prevent damage to its
components. To do so, follow these steps:
• Stop the pump.
• Close the valves of the suction and discharge pipes in order to isolate the filter.
• Open the drainage cap of the pressure gauge on top of the filter.
• Open the pressure gauge at the bottom of the filter.
• Empty the filter completely.
• Disassemble the filter.
• Clean all dirt from inside the filter.
• Clean the cartridge if necessary using a hose.
• Store the cartridge in a dry place protected from frost.
• Cover the filter with a bag to protect it from water and sunlight.
• Empty all pipes to prevent them from bursting due to freezing.
11. TROUBLESHOOTING:
PROBLEM
CAUSE
SOLUTION
Low filtration flow rate
Pump prefilter dirty
Clean the prefilter
Cartridge dirty
Clean the cartridge
Pipe blocked
Check valves, piping, etc.
Pump motors turn the wrong way
round
Change the direction of rotation
Pulsation of the pressure gauge
Air is entering the pump
Repair any possible leaks
Suction valve not fully open
Open the suction valves
Rapid pressure increase
Cartridge dirty
Clean the cartridge
Algae in the pool
Chemical treatment of the water
Cartridge dirty that has been used
flocculant
Remove the filter cartridge and
clean with pressure hose
Water not clean enough
Chemical treatment unsuitable
Change chemical treatment
Cartridge dirty
Clean the cartridge
12. SAFETY WARNINGS:
• The persons who are in charge of assembly should have the required qualifications for this type of work.
• Comply with the current standards regarding accident prevention.
• In this regard, the UNE-EN 60335-2-41 standards must be observed: Household and similar electrical
appliances - Safety - Part 2-41: Particular requirements for pumps.
• NEVER start up the system without water.
• NEVER allow children or adults to sit on the system.
• Do NOT connect the filter directly to the water network, as the pressure of the water may be too high and
exceed the maximum work pressure allowed by the filter.
• Do NOT use the filtering circuit to fill and adjust the water level of the pool. A handling error may lead to
overpressure in the filter.
• Do NOT clean the lid with solvents, as it may damage its properties (finish, transparency …).
• As all the connections are made with joints, it is not necessary to tighten the nuts excessively in order to
avoid that some plastic pieces could break.
• Do NOT use teflon in the T-part of the pressure gauge Kit, code 00545R0300, to ensure sealing.
• Do NOT use chemicals in powder form to treat the pool water as the filter could block up.