background image

Bruger-kal

i

brer

i

ng

:

 cAL

Fabr

i

kat

i

ons-kal

i

brer

i

ng

:

 CAL

Zero

Test

Mode

On

Off

C A L

S E L

S E L

C A L

Mode

On

Off

c A L

S E L

V

i

nk

Kal

i

brer

i

ngs

m

odus

On

Off

Mode

C A L

C l

C A L

R E S U L T A T E T   +   x

R E S U L T A T E T   +   x

R E S U L T A T E T   +   x

Mode

Zero

Test

0.0.0

Zero

Test

R E S U L T A T E T

R E S U L T A T E T

R E S U L T A T E T

C A L

Zero

Test

On

Off

:             :

An

m

ærkn

i

ng

C A L

c A L

M E T O D E

M E T O D E

M E T O D E

M E T O D E

M E T O D E

M E T O D E

Anbefalet Kal

i

brer

i

ngs værd

i

Klor

:

m

elle

m

 0,5 og 1,5 

m

g/l

pH

:

m

elle

m

 7,6 og 8,0

Cyanursyre

:

m

elle

m

 30 og 60 

m

g/l

Total Alkal

i

tet

:

m

elle

m

 50 og 150 

m

g/l CaCO

3

Calc

i

u

m

 hårdhed

:

m

elle

m

 100 og 200 

m

g/l CaCO

3

C A L

Tekn

i

ske ændr

i

nger forbeholdt

.

Pr

i

nted 

i

n Ger

m

any 07/98

Tryk på tasten MODE og 

hold den nede

.

Tænd apparatet 

m

ed tasten ON/OFF,

sl

i

p tasten MODE efter ca

.

 1 sek

.

Tryk på tasten MODE for 

m

etodesk

i

ft

:

CAL Cl 

A

CAL pH 

A

CAL Cys 

A

CAL S

:

4

.

A

CAL CA

.

....

 (rul)

Genne

m

før nulko

m

pensat

i

on so

m

 beskrevet

.

Tryk på tasten ZERO/TEST

.

Metodesy

m

bolet bl

i

nker 

i

 ca

.

 3 sekunder

.

D

i

splayet v

i

ser

:

Pos

i

t

i

oner den standard, der skal bruges, 

i

 analyse-

ka

mm

eret 

¢

6

   

.

Tryk på tasten ZERO/TEST

.

Metodesy

m

bolet bl

i

nker 

i

 ca

.

 3 sekunder

.

Resultatet v

i

ses på sk

i

ft 

m

ed CAL

.

Når resultatet 

m

odsvarer værd

i

en af den anvendte

standard (

i

nden for de tolerancer, der skal lægges t

i

l

grund), går 

m

an ud af kal

i

brer

i

ngs

m

odus ved at trykke

på tasten ON/OFF

.

1 x tryk på tasten MODE forhø

j

er det v

i

ste resultat 

m

ed 1

c

i

ffer

.

1 x tryk på tasten ZERO/TEST reducerer det v

i

ste resultat

m

ed 1 c

i

ffer

.

Tryk gentagne gange på tasterne, 

i

ndt

i

l det v

i

ste resultat

ste

mm

er overens 

m

ed den anvendte standards værd

i.

Ved tryk på tasten ON/OFF beregnes den nye
korrekturfaktor og lagres på bruger-kal

i

brer

i

ngsn

i

veauet

.

Bekræftelse af kal

i

brer

i

ngen (3 sekunder)

.

Fabr

i

kat

i

ons-kal

i

brer

i

ng er akt

i

v

.

Kal

i

brer

i

ng er udført af bruger

.

Apparatet kan t

i

lbageføres t

i

l t

i

lstanden ved udlever

i

ng

(fabr

i

kat

i

ons-kal

i

brer

i

ng) so

m

 følger

:

Hold tasterne MODE og NUL/TEST nede sa

mm

en

.

Slå apparat t

i

m

ed tasten ON/OFF

.

 Sl

i

p tasterne

MODE og ZERO/TEST efter ca

.

 1 sekund

.

D

i

splayet v

i

ser sk

i

ftev

i

s

:

Apparatet er 

i

 sa

mm

e t

i

lstand so

m

 ved udlever

i

ngen

.

(SEL står for Select

:

 udvælg)

eller

:

Apparatet arbe

j

der 

m

ed en af bruger udført kal

i

brer

i

ng

.

(Derso

m

 bruger-kal

i

brer

i

ngen skal b

i

beholdes, skal

apparatet slås fra 

m

ed tasten ON/OFF)

.

Ved tryk på tasten MODE akt

i

veres fabr

i

kat

i

ons-

kal

i

brer

i

ngen

.

 D

i

splayet v

i

ser sk

i

ftev

i

s

:

Apparatet slukkes på tasten ON/OFF

.

Kal

i

brer

i

ng 

"

out of range

"

Cl

:

Fabr

i

kat

i

ons-kal

i

brer

i

ng ukorrekt / slettet

pH

:

Fabr

i

kat

i

ons-kal

i

brer

i

ng ukorrekt / slettet

Cys

:

Fabr

i

kat

i

ons-kal

i

brer

i

ng ukorrekt / slettet

TA

:

Fabr

i

kat

i

ons-kal

i

brer

i

ng ukorrekt / slettet

CAH

:

Fabr

i

kat

i

ons-kal

i

brer

i

ng ukorrekt / slettet

Cl

:

Bruger-kal

i

brer

i

ng ukorrekt / slettet

pH

:

Bruger-kal

i

brer

i

ng ukorrekt / slettet

Cys

:

Bruger-kal

i

brer

i

ng ukorrekt / slettet

TA

:

Bruger-kal

i

brer

i

ng ukorrekt / slettet

CAH

:

Bruger-kal

i

brer

i

ng ukorrekt / slettet

Forebyggelse af fe

j

l ved foto

m

etr

i

ske 

m

ål

i

nger

1

.

Kuvetter, og rørep

i

nd skal renses grund

i

gt efter hver analyse for at

forh

i

ndre fe

j

l

.

 Selv s

m

å rester af reagens

mi

dler g

i

ver 

m

ålefe

j

l

.

 T

i

l rensn

i

ng

skal bruges den børste, der 

i

ndgår 

i

 leve-rancen

.

2

.

Kuvetternes yders

i

de skal være ren og tør, 

i

nden analysen genne

m

føres

.

F

i

ngeraftryk eller vanddråber på kuvetternes lysgenne

m

trængn

i

ngsflader

g

i

ver 

m

ålefe

j

l

.

3

.

Nulko

m

pensat

i

on og test skal genne

m

føres 

m

ed sa

mm

e kuvette, da

kuvetterne kan have 

mi

ndre tolerancer 

i

ndbyrdes

.

4

.

Kuvetten skal ved nulko

m

pensat

i

on og test alt

i

d anbr

i

nges sådan 

i

analyseka

mm

eret, at 

i

nddel

i

ngen 

m

ed den hv

i

de trektant peger ud 

m

od

prøvetageren

.

5

.

Nulko

m

pensat

i

on og test skal ske 

m

ed lukket kuvetterlåg

.

6

.

Sku

m

bobledannelse på kuvettens 

i

ndervægge g

i

ver 

m

ålefe

j

l

.

 I så fald

lukkes kuvetten 

m

ed kuvettelåget, og boblerne opløses ved at ryste

kuvetten, 

i

nden testen genne

m

føres

.

7

.

Det 

m

å forh

i

ndres, at der trænger vand 

i

nd 

i

 analyseka

mm

eret

.

Indtrængn

i

ng af vand 

i

 foto

m

eterhuset kan føre t

i

l ødelæggelse af

elektron

i

ske ko

m

ponenter og korros

i

onsskader og dækkes 

i

kke af

garant

i

en

.

8

.

T

i

lsnavsn

i

ng af de opt

i

ske dele (lysd

i

ode og fotosensor) 

i

 analyse-

ka

mm

eret g

i

ver 

m

ålefe

j

l

.

 Analyseka

mm

erets lysgenne

m

trængn

i

ngsflader

skal 

j

ævnl

i

gt kontrolleres og evt

.

 renses

.

 Velegnet t

i

l denne rensn

i

ng er

fugtklude og vatp

i

nde

.

9

.

T

i

l analyserne skal der udelukkende bruges reagens

mi

ddel-tabletter 

m

ed

sort fol

i

ertyk

.

 Ved beste

mm

else af pH-værd

i

en skal PHENOLRED-

tabletternes fol

i

e endv

i

dere være 

m

ærket 

m

ed PHOTOMETER

.

10

.

Reagens

mi

ddel-tabletterne skal t

i

lsættes t

i

l vandprøven d

i

rekte fra fol

i

en

uden at have været berørt 

m

ed f

i

ngrene

.

11

.

Større te

m

peraturforskelle 

m

elle

m

 foto

m

etret og o

m

g

i

velserne kan g

i

ve

m

ålefe

j

l, f

.

eks

.

 ved dannelse af kondensvand o

m

kr

i

ng de opt

i

ske dele

eller på kuvetten

.

E 10

E 70

E 72

E 74

E 71

E 73

E 75

E 76

E 77

E 79

E 78

R

i

gt

i

g påfyldn

i

ng af kuvette

forkert

r

i

gt

i

g

10 

m

l

10 

m

l

Summary of Contents for 54568

Page 1: ... the cap tightly and place the vial in the sample chamber making sure the Δ and marks are aligned Press the ZERO TEST key The method symbol flashes for approx 3 seconds The mg l CaCO3 value is shown in the display Rinse the vial and cap thoroughly after each test Tolerance 5 Full Scale Total Alkalinity 5 200 mg l CaCO3 0 0 0 R E S U L T R E S U L T Zero Test tA Switch the unit on using the ON OFF ...

Page 2: ...ess both the MODE and ZERO TEST and keep them depressed Switch the unit on using the ON OFF key Release the MODE and ZERO TEST keys after approx 1 second The following messages will appear in turn on the display The calibration is reset to the factory setting SEL stands for Select or Calibration has been set by the user If the user calibration is to be retained switch the unit off using the ON OFF...

Page 3: ...ondes Les résultat s affiche en mg l chlore total c Chlore combin Chlore combiné chlore total chlore libre Tol rance 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Procéder au calibrage du zéro voir Mise en service Ajouter une pastille de PHENOLRED PHOTOMETER dans l échantillon de 10 ml en la sortant directement de la feuille de protection sans la to...

Page 4: ...de CAL Cl CAL RESULTAT x RESULTAT x Mode Zero Test 0 0 0 Zero Test R E S U L T A T R E S U L T A T CAL Zero Test On Off Remarque CAL cAL M E T H O D E M E T H O D E M E T H O D E M E T H O D E Valeures de calibrage recommand Chlore entre 0 5 et 1 5 mg l pH entre 7 6 et 8 0 Acide cyanurique entre 30 et 60 mg l Alcalinité totale entre 50 et 150 mg l CaCO3 Dureté calcique entre 100 et 200 mg l CaCO3 ...

Page 5: ... Tolerancias 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Realizar la calibraci n a cero v ase instrucciones A los 10 ml de prueba acuosa a adir directamente de su envoltura una tableta PHENOLRED PHOTOMETER y machacarla con una varilla limpia Disolver completamente la tableta cerrar la cubeta con su tapa y posicionarla Δ Presionar ZERO TEST El s mb...

Page 6: ...roduce errores de medici n En este caso se tapa la cubeta y las burbujas se disuelven girando la cubeta antes de realizar el an lisis 7 La infiltraci n de agua en la c mara de medici n debe ser evitada La entrada de agua en la caja del fot metro puede destruir las piezas de construcci n electr nicas y producir da os de corrosion 8 El ensuciamiento de la ptica diodo luminoso y fotosensor en la c ma...

Page 7: ... de método presionar la tecla MODE CAL Cl CAL pH CAL Cys CAL S 4 3 Scroll Realizar la calibración a cero como descrito Presionar la tecla ZERO TEST El símbolo del método parpadea durante aproximadamente 3 segundos En el display aparece alternativamente Colocar el estándar a utilizar en el compartimento de medición según las marcas Presionar la tecla ZERO TEST El símbolo del método parpadea durante...

Page 8: ...y appare il risultato in mg l del cloro totale c Cloro combinato Cloro legato cloro totale cloro libero Tolleranza 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Condurre la taratura a zero vedere la messa in funzione Aggiungere direttamente nei 10 ml dell acqua di prova una compressa di PHENOLRED PHOTOMETER senza toccarla con le dita e frantumarla c...

Page 9: ... e le bollicine si dissolvono agitando la cuvetta prima di procedere al test 7 Si deve impedire la penetrazione di acqua nel pozzetto di misurazione L entrata dell acqua nel corpo del fotometro pu comportare un danneggiamento dell elettronica e danni dovuti a corrosione 8 L apparecchiatura ottica diodo luminoso e fotosensore nel pozzetto di misurazione se sporca comporta errori di misurazione Le s...

Page 10: ...ffettuata dall operatore scorretto cancellato E 10 E 70 E 72 E 74 E 71 E 73 E 75 E 76 E 77 E 79 E 78 Calibrazione effettuata dall operatore cAL Calibrazione effettuata in fabbrica CAL Zero Test Mode On Off CAL SEL SEL CAL Mode On Off cAL SEL Indicazione Metodo di calibrazione On Off Mode CAL Cl CAL RISULTATO x RISULTATO x Mode Zero Test 0 0 0 Zero Test R I S U L T A T O R I S U L T A T O CAL Zero ...

Page 11: ...rdar 2 minutos por uma reacção colorida Pressione a tecla ZERO TEST O símbolo CA H piscará durante 3 segundos O resultado aparecerá no visor expresso em mg l CaCO3 Tolerância 5 em toda a escala Efectue a leitura do Zero Ver manuseamento Retire a célula do compartimento de teste adicione um comprimido ALKA M PHOTOMETER e esmague o até se dissolver por completo usando um triturador limpo Feche a cél...

Page 12: ...itura Se houver suspeita de contaminação examine o visor 9 Quando usar reagentes em comprimidos use apenas comprimidos protegidos com folha metálica No caso dos comprimidos PHENOLRED devem estar marcados na folha metálica com PHOTOMETER 10 Os comprimidos devem ser adicionados à amostra de água sem serem tocados com os dedos 11 Elevadas diferenças de temperatura entre o fotómetro e o ambiente de tr...

Page 13: ...n de display verschijnt het meetresultaat in mg l totaal chloor c gebonden Chloor gebonden chloor totaal chloor vrij chloor Toleranties 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Doe de nulstelling zie In bedrijf nemen Doe een PHENOLRED PHOTOMETER tablet direkt uit de folie in 10 ml monsterwater en maak deze fijn met een schone roerstaaf Tablet g...

Page 14: ...igingen voorbehouden Printed in Germany 09 00 Druk op de MODE toets en houd deze ingedrukt Schakel de fotometer in met de ON OFF toets laat na ca 1 seconde de MODE toets los Druk voor het wisselen van het meetbereik de MODE toets CALCl CALpH CALCys CAL tA CALCA H Scroll Doe de normale nulstelling Druk de ZERO TEST toets Het methode symbool knippert ca 3 seconden In de aanwijzing verschijnt afwisse...

Page 15: ...EST Metodesymbolet blinker i ca 3 sekunder Displayet viser resultatet i mg l klor total c bundet klor bundet klor klor total frit klor Tolerance 0 1 mg l 0 05 mg l 3 4 mg l 0 30 mg l 1 2 mg l 0 10 mg l 4 6 mg l 0 40 mg l 2 3 mg l 0 20 mg l Gennemfør nulkompensation se ibrugtagning En PHE NOLRED PHOTOMETER tablet tilsættes til 10 ml vandprøven direkte fra folien og knuses med en ren rørepind Opløs ...

Page 16: ...tiveres fabrikations kalibreringen Displayet viser skiftevis Apparatet slukkes på tasten ON OFF Kalibrering out of range Cl Fabrikations kalibrering ukorrekt slettet pH Fabrikations kalibrering ukorrekt slettet Cys Fabrikations kalibrering ukorrekt slettet TA Fabrikations kalibrering ukorrekt slettet CAH Fabrikations kalibrering ukorrekt slettet Cl Bruger kalibrering ukorrekt slettet pH Bruger kal...

Reviews: