3
Concrete swimming pool with Liner:
Fig. 3
Prefabricated swimming pool:
Fig. 5
Panelled swimming pool with Liner:
Fig. 6
4. ASSEMBLY:
Prior to installation verify that the gland seal (no. 7) has been fully tightened.
Once the recess has been installed, place the trimming (no. 12), by pressing and making sure that the “stairs” is on
the inferior part.
To connect the projector to the mains, insert the cable through the packing gland nut (no. 7) the recess. Tighten the
packing gland nut until you see that the cable does not move when pulled.
Take care to leave 1.5 m. of cable wound inside the recess (no. 17) in order to be able to remove the projector to the
edge of the pool if it needs to be repaired or the lamp changed. (Fig. 6).
Insert the whole projector unit into the recess (Fig. 7), through the two slots of the large face plate, taking care to
correctly place the two pivot pins with the two flat sides in the slots of the face plate, and fully push it to the bottom.
The screw should be at the bottom and in the OPEN position (Fig. 8).
Turn the projector unit to the required slant and turn the lower screw to the CLOSED position (Fig. 9).
5. MAINTENANCE:
To remove the projector to the edge of the pool (Fig. 4), place the lower screw in the OPEN position, turn the
projector unit about 45º and remove it from the recess (Fig. 10).
To remove the lamp, unscrew the 6 nuts (no. 10) that anchor the fastening ring (no. 3) to the bottom of the projector
(no. 6) (Fig. 11).
Remove the lamp (no. 4) from inside the bottom of the projector and disconnect the 2 terminals, by loosening the
two screws which fasten them to the lamp (Fig. 12).
Change the lamp and assemble the Floodlamp, in the opposite order described in point 4 of assembly, taking special
care to:
•
Connect the cable terminals to the lamp, using the 2 screws supplied with the lamp (Fig. 12).
•
Fully centre the 110x11 O-ring (no. 6) in its seat.
•
Firmly tighten the nuts.
Attention:
•
Before any handling ensure that there is NO voltage supplied to the floodlamp.
•
The new lamp should have the same characteristics as that supplied with the floodlamp, PAR 56 300 W 12 V.
•
In order to ensure full watertightness, clean the seat of the O-ring (no. 6) for the lamp or replace the O-ring if you
observe any notches or permanent damage.
6. START-UP:
Ensure that the voltage the lamp receives is never greater than 12 V.
The floodlamp should only operate underwater while secured to the vertical walls of the pool. Never switch on the
floodlamp if it is not underwater.
7. SAFETY WARNINGS:
•
The persons who are in charge of assembly should have the required qualificatlons for this type of work.
•
Avoid making contact with the electric voltage.
•
Comply with the current standards regarding accident prevention.
•
In this regard, the IEC 364-7-702 standards must be observed. WIRING IN BUILDINGS. SPECIAL WIRING.
SWIMMING POOLS.
•
Any operation related to the maintenance or replacement of parts should be performed with the floodlamp
disconnected from the electric power system.
•
Do not handle with wet feet.
•
The manufacturer is not responsible in any circumstances for assembly, installation or start-up of any electric
components which have been inserted or handled at locations other than Its own premises.
•
It is recommended not to use sealing filler in this product and in any case. only use products specifically designed
to work with ABS. Universal products should not be used.
Summary of Contents for 33034
Page 14: ...14 24 1 2 3 5 6 7 12 13 14 15 16 17 19 11 21 22 4 18 20 10 18 9 7 8 8 9 23...
Page 17: ...17...
Page 18: ...18...
Page 19: ...19...