INST 291 RC9 Series Controller V12_17
9
18.
If Optomizer option is selected and fitted, you can change the Optomizer measure cycle time. This can be set
between 6 – 40 minutes. The lower this is set the more often the unit will measure and dose your pool water.
19.
“TIMER” is set default to ENABLED. If you are using an AstralPool controller or similar, change this to NOT
ENABLED. If NOT ENABLED is selected, you will be asked if a G4 system is installed. Select installed for all
compatible AstralPool controllers including Viron Connect, Genus 4 and Genus 3 controller. For all non AstralPool
controllers, select NOT INSTALLED to this option.
20.
“FAST COMMS” is only used when a Viron Connect touch screen controller is connected to the RC9 dosing system.
If a Viron Connect system is connected, change this option to ENABLED. For all other controllers, this option needs
to be changed to NOT ENABLED.
21.
“FLUSH AFTER TIMER” will bring the filtration pump on momentarily to flush out any residual chemicals from the
mixing cell. This will occur approximately 30 minutes after the timer period has finished. This should be left YES
(this option is only shown where the TIMER has been enabled)
22.
“RESET SYSTEM” select NO
The installation set up is now complete.
RC9 – TIMER SET UP (ONLY IF TIMER SELECTED)
1.
Using the POOL MODE button, switch the RC9 to manually off.
2.
Press the CLOCK button to the left of the screen and you will have the following options;
3.
To change the day, press the DAY button first then use the up and down arrows. Repeat for the HOUR and MIN
settings. Once complete, press the CLOCK button.
4.
Press the TIMER button to the left of the screen and you will have the following options;
5.
Using the up and down arrows in conjunction with the HOUR and MIN buttons, set the time you want the filtration
pump to start at. Press NEXT when done.