Fig. 5
Smoke pipe installed partly inside a house and partly inside an existing flue.
Yes
Chimney tee with a cap and a
peephole
45° bend, Ø 80 mm
Chimney cover plate
Airtight steel sheeting
YES
NO
FIG.6
FIG.9
YES
FIG.10
FIG.5
NO
FIG.8
YES
YES
FIG.7
2500 mm
.
max.
H > 4000 mm H > 1500 mm
8
3
4
1
2
9
10
11
5
7
6
12
Fig. 6
Whole smoke pipe installed inside a house.
Yes
Chimney tee with a cap and a
peephole
Chimney cap for rain
protection
This type of installation (Fig. 5) does not require
an insulated flue as the smoke pipe is assembled
partly inside the house and partly inside an
existing flue. A chimney tee with a peephole cap
is installed in the lower part of the flue.
Please note the use of two 45° bends in order
to guarantee that ash falls into the chimney tee
with the cap and the peephole.
This type of installation (Fig. 6), does not require
an insulated flue, because the whole smoke pipe
is assembled inside a house. A chimney tee with a
peephole is mounted in the lower part of the flue.