Ensure the free end of the supply hoses are passed through the recess in the bottom left hand 

side of the carcass of the rise and fall unit. 

 Connect the end of the supply hoses with the Conex fitting to the tap connectors. 

 

Fit the tap levers:

Remove the handle caps, to reveal the fixing screws; fit the spline adaptors and levers to the tap 

bodies. Care should be taken to ensure that the lever assemblies do not foul the tap bodies. If a 

lever fouls the tap body, it needs to be adjusted. To do this, release the large brass nut on the 

underside of the basin, tighten the chrome ring fitted to the tap body until sufficient clearance is 

achieved. Once fully adjusted, re tighten the large brass nut.  

Test the water supply:

Ensure the isolation valves are 

CLOSED

. Place a bucket or suitable container below the plug hole 

of the basin. Open both basin taps fully and then slowly open each of the isolation valves, wait 

 minutes, then examine the supply system for leaks, correct as necessary. Close the isolation 

valves.

Fit the white plastic lower cover:

Remove the mushroom heads from the plastic rivets and place aside, fit the bodies into the six 

holes in the frame

Remove the P Trap and straight coupling from 

the waste assembly

Feed the free end of the flexible hose through 

the cut out in the lower right hand side of the 

frame, leave the waste assembly in position 

sccure with cable tie supplied.

Fit the lower cover taking care to position it 

correctly

Refit the rivet heads, push each of the 

mushroom portions of the white plastic rivets 

COLD
SUPPLY

HOT
SUPPLY

Hoses 
Rear view

Touch tap 
control
box

Summary of Contents for ABW6

Page 1: ...Warranty No Height Adjustable Basin ABW6 OWNERS MANUAL INSTALLATION GUIDE ...

Page 2: ...ould be facing forward towards the user when off To operate them rotate the levers outwards to achieve the flow rate required To stop water flowing rotate the levers until they are facing forward once again Operating the touch tap system The taps are usually set as wave ON Wave OFF To turn the water ON OFF pass your hand above the Sensor on the basin top Touch Tap Sensors in position ...

Page 3: ... unit Examine the mains fuses circuit breakers and reset as necessary and ensure that mains voltage is fully reconnected then press the reset button situated next to the handset connector If the LED fails to illuminate an electrician needs to ensure that mains electrical supply is available at the fused spur a fuse may have blown elsewhere in the circuit Fault The rise and fall unit travels upward...

Page 4: ...ble waste assembly including waste plug 1 x three hole mixer tap system 2 x 95mm long 15mm copper pipe 2 x 45mm long 15mm copper pipe 2 x compression elbow 15mm 2 x 15mm straight couplings 2 x 1 2 x 15mm Tap adaptors 2 x lever tap handles 2 x long braided hoses 2 x fibre washers 2 x screen filter seals 1 x 470mm lipped attachment rail 1 x grey 2 button handset 6 x white plastic rivets 1 x mirror 1...

Page 5: ...equired with flush mounted a flex outlet cover on the wall behind the unit at a height of 1100mm from the floor on the centreline of the unit Fixing The basin assembly should be fixed to a load bearing wall i e strong enough to carry a 100kg load on wall fixing which is flat and free from obstruction from 200mm 2200mm above the floor If the basin needs to be fixed to a stud wall the wall will need specia...

Page 6: ...ith the one on the wall Ensure that the unit is level then mark the wall through the remaining three attachment points two on the lower horizontal beam and one on the upper horizontal beam Remove the unit from the wall and at the three marked positions drill three 6mm full depth pilot holes Open the two to accept Anchor fixings Open the upper hole to 10mm to accept a plastic wall plug Fit the fixi...

Page 7: ...ke sure the rod can move freely Using the adjusting screw set the overall length of the basin plug to 77mm Stand the lower cover in place Fit the plug lifting rods in position and set the clamp to lift the plug Touch taps Fit the sensors before mounting the unit on the wall Touch tap sensors should be fitted in the position agreed with the client Drill an 18mm in the position required take care to...

Page 8: ... brass nut Test the water supply Ensure the isolation valves are CLOSED Place a bucket or suitable container below the plug hole of the basin Open both basin taps fully and then slowly open each of the isolation valves wait 2 minutes then examine the supply system for leaks correct as necessary Close the isolation valves Fit the white plastic lower cover Remove the mushroom heads from the plastic ...

Page 9: ... supply hoses need to be enclosed within the white self adhesive trunking supplied Using the handset raise the assembly to its highest position Remove the capping from the front of the trunking Remove the protective film from the self adhesive tape fitted to the rear of the trunking Pass the trunking behind the hot and cold supply hoses taking care to ensure that the self adhesive tape is kept awa...

Page 10: ...Page 10 Version 3 01 04 2016 ...

Page 11: ...Page 11 Version 3 01 04 2016 ...

Page 12: ...821110 Technical Helpline 01242 822972 2013 Astor Bannerman Medical Limited Our policy is one of continuous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copied either whole or in part without the consent of Astor Bannerman Medical Limited Original Document ...

Reviews: