Symptoms

Possible Causes

Solutions

No power to unit

1. Pump not plugged in

2. GFCI Breaker tripped
3. No power to GFCI

1. Verify and check all

power connections

2. Unit MUST be
connected to a GFCI

Breaker

3. Verify power to GFCI
outlet

No water from shower

wand

1. Incorrect diverter

position

2. Incorrect plumbing

1. Verify you have the

diverter setting on the
Showerhead location
2. Verify all plumbing
connection
3. Verify all water supply

valves are open

Bath tub Fill not working

No water from the bath

tub fill spout

1. Divert MUST be

located on the

Showerhead location.
2. Verify all plumbing
connection
3. Verify all water supply

valves are open

Whirlpool jets not
working

1. Not enough water in

the tub
2. No power to the jet

pump

3. Air button tubing

broken or not connected

1. Water level must be

above the suction cover

in order for the whirlpool

jets to operate.

2. Verify all power
connections and voltage
to the pump
3. Check the air tube

between the button and
pump

Door seal leaking

1. Door not closed and

locked

2. Damage to door seal

1. Verify door is closed

and locked
2. Contact dealer or

manufacture

20

             Troubleshooting

 

Summary of Contents for WT62311J-AC-II-R

Page 1: ......

Page 2: ......

Page 3: ...ils to operate as described the GFCI is defective and must be replaced If the GFCI interrupts power to the unit without the test button being pushed a ground fault has occurred Discontinue use and con...

Page 4: ......

Page 5: ...Circuit Interrupter USA Breaker that interrupts the flow of electricity when it detects voltage going to ground This type of breaker is required to connect any whirlpool bath steam shower or hot tub...

Page 6: ...in the USA RCD breakers are used outside the US and Canada Suction Fitting Located at the bottom of a hydro massage tub used to return water back into the pump Must be installed before use of a hydro...

Page 7: ...to customers using three conductors with the following color code and voltage Line L 230 VAC Brown Neutral N Blue Ground G Yellow Green VAC Voltage for Alternating Current VDC Voltage for Direct Curr...

Page 8: ......

Page 9: ...hot water to diverter Door Entry point for the user Suction Return for the jet pump Lock To control the door open close turn the lock clockwise to close the door turn the lock counter clockwise to ope...

Page 10: ......

Page 11: ...nnection fittings standard male 3 8 compression threads 1 5 PVC elbows 1 5 PVC pipe 1 5 to 2 reducer if the floor drain is 2 pipe Plumbing Requirements Water Pressure 40 60 psi for both hot and cold s...

Page 12: ...l left up on the shelf bar to remove not tools are needed Optional Side panel Feature varies by model Units that are intended to be installed in a corner or free standing may have an optional side pan...

Page 13: ......

Page 14: ......

Page 15: ...on your supply connections for the supply hot and cold to aid in any needed future service of the unit Using the flexible line make the supply hot and cold connections The unit MUST be connected to a...

Page 16: ...and lock the door rotate the handle clockwise to secure Diverter valve The diverter valve is used to control the flow of water to the following devices The overhead shower The body jets The shower wa...

Page 17: ...ub is drained by gravity the large drain open will drain the tub quickly You have 2 options to drain the tub 1 Rotate the Overflow cover counter clockwise to open the drain 2 Using the auxiliary Drain...

Page 18: ...our desired temperature Tub Faucet 1 Rotate the diverter valve to the Tub faucet position 2 Turn the ON OFF valve to the ON position 3 Set the thermostatic valve 4 When finished rotate the ON OFF valv...

Page 19: ...covers located at the bottom of the tub This is a safety feature running the jet pump with out water will damage the pump and void the warranty Fill the tub until the water line is above the top jets...

Page 20: ...ated for acrylic surfaces You can buff and polish the acrylic surface using any good polishing compound such as Maguire s 10 Mirror glaze toothpaste or automotive polishing paste Using these types of...

Page 21: ...Fill not working No water from the bath tub fill spout 1 Divert MUST be located on the Showerhead location 2 Verify all plumbing connection 3 Verify all water supply valves are open Whirlpool jets not...

Page 22: ...ranty This warranty applies to all plumbing components including jets tubing fittings shower wand shower wand hose and supplied connection hoses Only the plumbing fixture components such as faucets di...

Page 23: ...DISTRIBUTOR SERVICE COMPANY OR OTHER PARTY IS AUTHORIZED TO CHANGE MODIFY OR EXTEND THE TERMS OF THIS WARRANTY IN ANY MANNER WHATSOEVER Disclaimers Aston Global and it representatives shall not be li...

Page 24: ...Aston Global offers free phone support for the life of the Product to the original Owner which is non transferable 23...

Page 25: ...Customer Service 877 424 9699 Aston Global Inc 1501 10th St Suite 150 PLANO TX 75074 If further assistance is needed or you have a question please visit our web site at www astonglobalinc com...

Reviews: