background image

 

Note: 

 

All the stainless steel fixing screws (M6x80) it is highly recommended to be sealed in the 

contact with underwater light casing by optional TEF-GEL

TM

  waterproof paste (not 

included) to prevent galvanic corrosion. 

 

Note: 

 

To install the underwater light on the steel hull it is highly recommended to use the 

optional isolation board (not included) between the hull and underwater light casing to 

prevent galvanic corrosion. 

 

Note: 

 

Do not overtighten the screws as this can result in hull or underwater light damage. 

 

Bonding 

The underwater light has to be connected to the vessels bonding and cathodic protection using a pre-

tinned wire a minimum of 8 AWG (8.36 mm

2

) with green insulation or green with a yellow stripe. The 

wire has to be connected to the underwater light by the help of one screw M6x80 and connected to 

that screw from the inside of the hull. 

 

Note: 

 

It is highly recommended to paint the entire underwater casing exposed to the water with 

anti-foul paint. 

 

The optical window is protected with foil which has to be removed after anti-fouling 

process. 

 

Connection 

The power supply has to be connected through the main switch (not included) with correct polarity 

and protected by a fuse (not included). The power supply voltage has to be from 20 - 30Vdc. 

 

Note: 

 

The main DC power supply of the vessel has to be switched off before installation. 

 

The underwater light has to be connected as described in the table below: 

 

EQUATOR MSR36240P 

wire color

 

FUNCTION 

Red 

+ DC Power Supply 

Black 

GND Power Supply 

Orange 

+ Control 

Brown 

GND Control 

 

Remote control connection 

Single-color white (W), blue (B) or green (G) models 

To remotely turn-on and turn-off the underwater light the simple switch (not included) can be used 

and connected to the CONTROL wires by a 2-pole signal cable (not included). 

 

Note: 

 

If  the  remote control is not used  at single-color models  for normal operation the both 

CONTROL wires have to be bridged and insulated or connected to the GND.

 

 

Optional PWM dimmer MDU13 can be connected to the CONTROL wires by using a 2-pole signal 

cable (not included). 

 

 

Summary of Contents for EQUATOR MSR36240P Series

Page 1: ...EQUATOR MSR36240P UNDERWATER LIGHT Operating Instructions...

Page 2: ...Precautions 3 Components and Connectors 4 Installation 5 Controls 7 Appearance 9 Technical Specifications 9 Warranty 10 Declaration of Conformity 11 __________________________________________________...

Page 3: ...Metalized Reflector Remote Control Digital Dimming Built in ASTEL Protocol for DMX512 Control of Multi Color RGB version Polarity Protection Transient Protection Thermal Protection Low Power Consumpti...

Page 4: ...dow 2 Underwater light casing Aluminium bronze or stainless steel casing with fixing holes and cable gland 3 Cable The 4 pole multi core cable to connect the 24Vdc power supply and optional remote con...

Page 5: ...ight exceeds 85 C the underwater light is automatically switched off Hull preparation The underwater light is recommended to be installed around 0 2 m below the waterline for the best illumination and...

Page 6: ...exposed to the water with anti foul paint The optical window is protected with foil which has to be removed after anti fouling process Connection The power supply has to be connected through the main...

Page 7: ...l Remote control has to be used to turn on and turn off the underwater light and to control the mode of lighting and luminosity The multi color underwater light can be controlled by using the momentar...

Page 8: ...the system the optional Synchronization Unit MSU08 is recommended to synchronize the colors of lighting at the Rainbow Color Spectrum mode of lighting On the other case the colors of all installed lig...

Page 9: ...grade polycarbonate glass Luminous flux max 8 300 lm White color temperature 6 000 10 000 K ASTEL protocol default address 1 Operating temperature 10 C 50 C Casing Stainless steel SAE316L Protection...

Page 10: ...the Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of oppo...

Page 11: ...ATOR MSR36240P conform to the following Product Specifications EMC EN 55015 2006 A1 2007 EN 61547 1995 A1 2000 A2 2009 EN 61547 2009 Safety EN 60598 2 18 1995 A1 2012 EN 60529 1992 A2 2013 Supplementa...

Page 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel marine com Web www astel marine com...

Reviews: