Speed mode 

Defines the ASTEL protocol communication baud rate. 

 

Value

 

FUNCTION

 

LOW speed – 1200 bps 

MID speed – 2400 bps 

HIGH speed – 4800 bps 

 

 

Number of addressable lights 

This defines how the OUT is acting. There are two basic modes: 

 

-non addressable – all the lights on the control OUT light in the same way 

 

-addressable – there can be up to 15 address and each light connected to the OUT can have 

the address from 1 to 15 – each light with different address can light different. There can be more 

than one light with the same address – the number of the lights with the same address is not limited! 

 

To set-up non addressable mode set the switches 1 - 4 to OFF. 

To set-up addressable mode set the switches  1  -  4  to  the  number of the lights with different 

addresses on the control OUT. 

Please pay attention the higher number results in lower refresh rate! 

 

 

Data type 

This defines the number of data bytes used for light / the number of DMX channels for each light on 

the control OUT. 

 

Value

 

FUNCTION

 

1 byte - not used 

2 bytes - not used 

3 bytes - RGB lights 

4 bytes - not used 

 

Non addressable mode: 

The number of used DMX channels is same as the defined. 

 

Addressable mode: 

The number of used DMX channels used for control OUT is as follows: 

 

DATA TYPE number x number of ADDRESSABLE LIGHTS 

 

Example: 

DATA TYPE = 2 – 3 bytes 

Number of ADDRESSABLE LIGHTS = 5 

DMX channels used = 3 x 5 = 15 

 

 

Set default 

Sets the parameters to their default values: 

 

Parameter 

Value 

Speed mode 

Number 

Data type 

Summary of Contents for LXU01

Page 1: ...LXU01 DMX512 INTERFACE Operating Instructions...

Page 2: ...ns 3 Controls and Connectors 4 DMX512 Interface LXU01 4 Installation 5 Set up 6 Appearance 8 Technical Specifications 8 Warranty 9 Declaration of Conformity 10 ________________________________________...

Page 3: ...er Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation PRECAUTIONS The DMX512 Interface LXU01 has to be installed and used in accordance with the i...

Page 4: ...c power supply 2 OUT Control output to connect the Control P and GND Control wires of multi color RGB lights Meteor series or PWM dimmer LDU13 3 CONTROL The 3 pole terminal block connector to connect...

Page 5: ...el Note The main DC power supply has to be switched off before installation Power supply connection The power supply has to be connected through the switch not included and protected by a fuse not inc...

Page 6: ...itch is used to set up the mode of operation and programming DIP switch switches FUNCTION 1 4 Parameter 5 8 Mode of operation 9 10 Not used 11 Programming trigger 12 Programming mode The set up proced...

Page 7: ...switches 1 4 to OFF To set up addressable mode set the switches 1 4 to the number of the lights with different addresses on the control OUT Please pay attention the higher number results in lower ref...

Page 8: ...on 8 Set the programming mode with the switches 5 8 to ON position 9 Set the light new address to 1 15 with the switches 1 4 10 Connect the light to the power supply and IMMEDIATELY continue with step...

Page 9: ...he Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of oppor...

Page 10: ...and Model Number 1 DMX512 Interface LXU01 conform to the following Product Specifications EMC EN 55103 1 2009 A1 2012 Safety EN 62368 1 2014 Supplementary Information The products herewith comply with...

Page 11: ...11...

Page 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel lighting com Web www astel lighting com...

Reviews: