background image

 

SET-UP 

 

 

The DMX512 Interface LXU01 set-up is enabled by adjusting the DIP-switch. 

 

 

 

 

DIP-switch 

1-2-3-4 

VALUE 

 

OFF-OFF-OFF-OFF

 

ON –OFF-OFF-OFF 

OFF-ON –ON –ON 

14 

ON –ON –ON –ON 

15 

 

 

 

 

 

 

DIP-switch 

1-2-3-4-5-6-7-8-9 

VALUE 

 

OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF

 

ON -OFF-OFF-OFF-OFF-OFF-OFF-OFF-OFF

 

ON –ON -OFF-OFF-ON -OFF-ON –ON -OFF

 

211 

OFF-ON –ON –ON –ON –ON –ON –ON -ON 

510 

ON –ON –ON –ON –ON –ON –ON –ON -ON 

511 

 

In normal operation the switches 1 - 9 define the DMX address! 

 

Note: 

 

The switch 12 must be in OFF position for normal operation! 

 

The DIP-switch is used to set-up the mode of operation and programming 

 

DIP-switch 

switches 

FUNCTION 

 

1 - 4 

Parameter 

5 - 8 

Mode of operation 

9 -10 

Not used 

11 

Programming trigger 

12 

Programming mode 

 

 

The set-up procedure: 

1.  Set the switch 12 to ON position 

2.  Set the programming mode with the switches 5 – 8 as described below 

3.  Set the parameter value as described below 

4.  Set the switch 11 to ON position 

5.  Wait for 5 seconds 

6.  Set the switch 11 to OFF position 

7.  Set the switch 12 to OFF position 

 

 

DIP-switch 

5-6-7-8 

DIP-switch 

1-2-3-4 

SET-UP 

OFF-OFF-OFF-OFF 

0-2 

Speed mode 

ON -OFF-OFF-OFF 

0-15 

Number of addressable lights 

OFF-ON -OFF-OFF

 

0-3 

Data type 

OFF-ON –ON -ON

 

not used 

Set default 

ON– ON –ON -ON

 

1-15 

Programming the light address 

Summary of Contents for LXU01

Page 1: ...LXU01 DMX512 INTERFACE Operating Instructions...

Page 2: ...ns 3 Controls and Connectors 4 DMX512 Interface LXU01 4 Installation 5 Set up 6 Appearance 8 Technical Specifications 8 Warranty 9 Declaration of Conformity 10 ________________________________________...

Page 3: ...er Consumption Polarity Protection Transient Protection Short Circuit Output Protection Simple Installation PRECAUTIONS The DMX512 Interface LXU01 has to be installed and used in accordance with the i...

Page 4: ...c power supply 2 OUT Control output to connect the Control P and GND Control wires of multi color RGB lights Meteor series or PWM dimmer LDU13 3 CONTROL The 3 pole terminal block connector to connect...

Page 5: ...el Note The main DC power supply has to be switched off before installation Power supply connection The power supply has to be connected through the switch not included and protected by a fuse not inc...

Page 6: ...itch is used to set up the mode of operation and programming DIP switch switches FUNCTION 1 4 Parameter 5 8 Mode of operation 9 10 Not used 11 Programming trigger 12 Programming mode The set up proced...

Page 7: ...switches 1 4 to OFF To set up addressable mode set the switches 1 4 to the number of the lights with different addresses on the control OUT Please pay attention the higher number results in lower ref...

Page 8: ...on 8 Set the programming mode with the switches 5 8 to ON position 9 Set the light new address to 1 15 with the switches 1 4 10 Connect the light to the power supply and IMMEDIATELY continue with step...

Page 9: ...he Purchaser at the Warrantor s expense d no refund of the purchase price will be granted to the Purchaser unless the Warrantor is unable to remedy the defect after having a reasonable number of oppor...

Page 10: ...and Model Number 1 DMX512 Interface LXU01 conform to the following Product Specifications EMC EN 55103 1 2009 A1 2012 Safety EN 62368 1 2014 Supplementary Information The products herewith comply with...

Page 11: ...11...

Page 12: ...12 ASTEL d o o Dutovlje 138 6221 Dutovlje Slovenia Tel 386 5 7310771 386 5 7310772 Fax 386 5 7310789 E mail info astel lighting com Web www astel lighting com...