3.7.7.9 Performance Monitoring
The A54812-SW switch supports event counters for performance monitoring and error monitoring on all switch
phys. An event counter can be configured to count one specific SAS event, such as transmitted SSP frames. Each
phy can have up to four event counters configured at a time. A configuration that specifies four event counters is
a config set. When a config set is specified, SDM sets all phys on the switch to use the same four event counters.
The use of switch counters does not impact the switch performance. Refer to the Phy Events section of the SAS
2.0 specification for more information about the counters used by the performance monitors and error monitors.
Figure 50 Performance Monitoring Operations
SDM-GUI supports the following three monitoring operations:
Display
– The
Display Performance Monitoring Config list
command shows the current configurations for all
available config sets as shown in the following figure. The user can choose one config set out of a predefined list.
This list is nonconfigurable by the user.