LDM41E and LDM42E Manual
Limiting Values for Voltages
ASTECH GmbH
Page 19
6
Limiting Values for Voltages
GND lines of the power supply and RS232 terminals are connected internally
and form the ground potential for all of the limiting values indicated below.
Input voltages:
Table 7 : Input voltages
Terminal point
Voltage
Comment
VCC
+10 up to +30 V
pole-reversal-protected
CONFIG
do not connect
reserved
TRIG
12
± 25 V
short-circuit-proof
RxD
± 25 V
short-circuit-proof
Output voltages:
Table 8 : Output voltages
Terminal point
Voltage
Comment
OUT
like VCC (R
i
135 mΩ)
max. 0.7 A load;
short-circuit-proof
TxD
±5.4 V
short-circuit-proof
Limiting values of voltages, loads and logical levels comply with relevant RS232
and Ethernet standards. All outputs are sustained-short-circuit-proof.
12
Trigger function is not available for devices with internal heating
(option
–h)