Configurable Parameters 

Configuration 

Parameters 

Parameter 

Number 

Size 

Description 

Silent mode on/off 

1  1 byte 

Level control, 1 = High Volume, 3 = Silent. Default is 1 
or High Volume
 

Auto Relock on/off 

2  1 byte 

0x00 = OFF, 0xFF = ON default is 0x00 or OFF 

Auto Relock time  

3  1 byte 

10 to 180 seconds default is 30 seconds 

Wrong Code Entry Limit 

4  1 byte 

3 to 10 default is 5 times 

Shut down time (after 
wrong code entries) 

7  1 byte 

10 to 180 seconds default is 60 seconds 

operating mode 

8  1 byte 

00 = normal mode (this is the default mode) 
01 = vacation mode, keypad lockout 

One Touch Locking 

11  1 byte 

0x00 = OFF, 0xFF = ON default is 0xFF or ON. 

Privacy Button 

12  1 byte 

0x00 = OFF, 0xFF = ON default is 0x00 or OFF 

Lock Status LED 

13  1 byte 

0x00 = OFF, 0xFF = ON default is 0x00 or OFF. 

Reset To Factory 
Defaults 

15  1 byte 

01 = Lock will execute Reset To Factory. 

No default value 

 

Summary of Contents for Yale Real Living Assure Lock YRD216

Page 1: ...16 Machine screws x4 7 wood 8 32 machine x 20mm Combination screws x2 M6x59 5mm Long through bolt FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRA...

Page 2: ...P N Rev E YRL PBINSTL FUL 2 Preparing Door...

Page 3: ...Rev E YRL PBINSTL FUL 3 O x4 1 d faut e 2 3 8 position 2 3 4 position Installing Latch Strike Plate Press Pull optional Bolt must be in retracted unlocked position Note horizontal orientation of mecha...

Page 4: ...P N Rev E YRL PBINSTL FUL 4 2 Installing Keypad Escutcheon Outside of Door Inside of Door Bolt must be in retracted unlocked position Note horizontal orientation of mechanism...

Page 5: ...P N Rev E YRL PBINSTL FUL 5 x2 3 Installing Interior Mounting Plate Loosen screw to remove cover...

Page 6: ...4 Attaching the Cable Assembly P N Rev E YRL PBINSTL FUL 6...

Page 7: ...P N Rev E YRL PBINSTL FUL 7 x3 5 Installing Interior Escutcheon...

Page 8: ...3 Testing Operation Bolt must be in retracted unlocked position before installing batteries P N Rev E YRL PBINSTL FUL 8...

Page 9: ...P N Rev E YRL PBINSTL FUL 9 2 Testing Operation...

Page 10: ...alling Batteries Cover Congratulations you ve installed the Yale Assure Lock Push Button Deadbolt 216 YRD Continue with Programming Instructions to customize your product Installing Optional Network M...

Page 11: ...11 Interior Escutcheon Exterior Escutcheon Privacy Mode Button Low Battery Warning Flashes RED Master Code must be created before any further programming PIN Max User Codes 250 with Network Module Max...

Page 12: ...1 Creating Master Code PIN Press Press Press Press Enter 4 8 digit Master Code PIN P N Rev E YRL PBINSTL FUL 12...

Page 13: ...s PIN Master code must be created first PIN Max User Codes 250 with Network Module Max User Codes 25 without Enter Master code PIN Press Press Press Press Press Press Enter 4 8 digit code PIN P N Rev...

Page 14: ...to 250 Users Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ Code Chart Duplicate if necessary User Name U...

Page 15: ...ckout Mode Disabled Interior Escutcheon Reset Button When lock is reset to factory defaults all user codes including the Master code are deleted and all PIN programming features are reset to original...

Page 16: ...ate unlock lock the lock Network Module Setting This setting is available thru the main Menu 7 and allows the lock to connect with a network controller It is also available through the wireless button...

Page 17: ...io Mode Default settings in bold Audio Mode N A All Code Lockout Mode Network Module Setting Join the Network Enable Enable Disable Exit the Network Disable This function appears only with network mod...

Page 18: ...r PIN codes must consist of 4 to 8 digits to register The same code cannot be used for multiple users PIN Registration management of codes is set by the PIN authority of the Master Code Contact the Ma...

Page 19: ...r relative to adjustments already made to bolt c Verify proper door preparation and re bore holes that are too small or misaligned d Verify keypad wire harness is routed under the bolt see Fig A e Ver...

Page 20: ...s connected Consult the dealer or an experienced radio technician for help TV Industry Canada This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regul...

Page 21: ...ial com ZwavePlus Adding Removing the Network Module This device is a security enabled Z Wave Plus product that is able to use encrypted Z Wave Plus messages to communicate to other security enabled Z...

Page 22: ...c une antenne d un type et un maximum ou moins approuv s pour gagner de l metteur par Industrie Canada Pour r duire le risque d interf rence aux autres utilisateurs le type d antenne et son gain doive...

Page 23: ...1 Yale Locks YRD416 Z Wave Plus System Integrators Guide Yale Assure Deadbolt Lock Document Revision 1 January 14 2019...

Page 24: ...2 Contents Yale Z Wave Plus Product Info 3 Supported Command Classes 3 Association Table 3 Notifications Table 4 Configurable Parameters 6...

Page 25: ...s Battery Command Class Door Lock Command Class Door Lock Logging Command Class Schedule Entry Lock Command Class User Code Command Class Time Parameters Command Class Time Command Class Association C...

Page 26: ...rn 0x02 by touch function lock and leave 0x03 By inside button RF Operate Lock 0x18 0x01 by RF module Keypad Lock 0x12 0x 01 max users Where Alarm level represents user slot number Non Access 0x26 0x...

Page 27: ...l be sent instead of the non access alarm Daily Repeating Schedule Set Erased 0x60 0x 01 max users Schedule s has been set erased for specified user ID Daily Repeating Schedule Enabled Disabled 0x61 0...

Page 28: ...Entry Limit 4 1 byte 3 to 10 default is 5 times Shut down time after wrong code entries 7 1 byte 10 to 180 seconds default is 60 seconds operating mode 8 1 byte 00 normal mode this is the default mod...