background image

Definitions

24

80-9086-0030-010   04-21

Part of ASSA ABLOY

All Code Lockout Mode: 

This feature is enabled by the Master PIN code. When enabled, it restricts all user (except 

Master) PIN code access. When attempting to enter a code while unit is in Lockout, there will be an audible lock 
response. The touchscreen keypad will display a RED locked padlock. (Main Menu selection #6.)

Automatic Re-lock Time:

 

After a successful unlock, the unit will re-lock automatically after 5 seconds or for a duration 

selected in the Advanced Lock Settings (Main Menu selection #3 then #1). 

Eco Mode:

 

When enabled, Eco Mode puts unit in low power mode extending life of battery.

Escape Return:

 

Enabling this function allows the door to remain unlocked in the case of an emergency. Escape Return 

will cause the door to automatically unlock upon opening and remain unlocked even if the door swings closed. The 
locking action requires at least one intentional user interaction to return to the locked state. Auto Re-lock cannot be 
enabled when Escape Return is enabled.

Inside Indicator Light:

 

This light will blink red when door is locked.

Language Setting Mode:

 

Choose English (1), Spanish (2) or French (3) for the lock's voice prompts. (Main Menu 

selection #5.)

Low Battery:

 

When the battery power is low, the Low Battery Warning indicator is a flashing red battery icon on the 

touchscreen keypad and the Yale logo will flash red on the push button keypad. If battery power is completely lost, use 
the 9Volt battery override. To use the 9V battery override apply 9V battery, in either direction, to terminals on the keypad 
for backup power option. Activate the keypad and enter your pin code to unlock the door.

Master PIN Code:

 

The Master PIN code is used for programming and for feature settings. It must be created prior to 

programming the lock. The Master code will also operate (unlock/lock) the lock except when Accentra Key Module is 
installed.

Network Module Setting:

 

With the optional Network Module installed, this setting becomes available (Main Menu 

selection #7) and allows the lock to connect with a network controller.

One Touch Locking:

 

When the unit is unlocked, activating the keypad will lock the unit (during Automatic Re-lock 

duration or when Automatic Re-lock is disabled). When One-Touch Re-lock is not in use (disabled), any valid PIN code 
will re-lock the lock. (Main Menu selection #3 then #3.)

Passage PIN Code:

 

When used to unlock, lock will remain unlocked/open. Lock cannot be locked/secured until 

Passage code is entered again.

Privacy Button to Lock Door:

 

If Automatic Re-lock is disabled, a short 1 second press of this button will lock the door. 

Privacy Mode:

 

With Privacy Mode enabled thru Menu Mode and door closed, all keypad functions can be disabled with 

a 3 second press of the Privacy Button. Privacy Mode is disabled by default. Enable Privacy Mode thru Main Menu 
selection #3 then #4. With door closed, press and hold the privacy button until voice prompt indicates Privacy Mode is 
enabled. Privacy Mode duration ends when door is opened and voice prompt indicates Privacy Mode is disabled.

Shut Down Time:

 

The unit will shut down for sixty (60) seconds and not allow operation after the wrong code entry 

limit (5 attempts) has been met. When the unit is in Shut down, the keypad will be flashing.

Tamper Alert:

 

Audible alarm sounds if attempting to forcibly remove outside lock from door.

User PIN Code:

 

The User code operates the lock. Maximum number of user codes is 500. 

Volume

 

Setting Mode:

 

The volume setting for PIN code verification is set to HIGH (1) by default; otherwise it can be set 

to Low (2) or Silent (3) for quiet areas. (Main Menu selection #4.)

Wrong Code Entry Limit:

 

After five (5) unsuccessful attempts at entering a valid PIN code, the lock will not accept a 

PIN code for the duration of the shut down time. The touchscreen keypad will flash, and a red lock symbol will be at the 
bottom of the keypad. The push button keypad will flash and the Yale icon will flash blue for the shut down period. The 
keypad will be available after the shut down time is complete.

Summary of Contents for Yale nexTouch

Page 1: ...s Sectional Mortise Lock Touchscreen and Push Button Installation and Programming Instructions 1 2 3 4 3 32 AA AA AA AA Optional 3 2 1 8 WARNING This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductiveharm For more information go to www P65warnings ca gov 08 2018 Tools Needed 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 2: ...om which you unlock and enter RED Locking Slide should face the secure side of door Latchbolt Beveled edge must face strike See step 1 to reverse latchbolt Deadbolt Key cylinder used for cylinder option installation Thumbturn used when mortise lock is equipped with deadbolt 2 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 3: ...of locking slide PUSH IN causing locking slide to rotate 3 RED MARK on locking slide must be on secure side of door Continue to rotate locking slide from other side until set in position Insert flat head screwdriver to pry latch head up Rotate latch head to correct orientation 3 1 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 4: ...t splitting Mortise Lock Cable Hole Drill only 1 2 way into door 7 8 depth then STOP Mortise Key Cylinder Hole Drill only 1 2 way into door ONLY if lock is equipped with cylinder Mortise Deadbolt Thumbturn Hole Drill only 1 2 way into door ONLY if lock is equipped with deadbolt 2 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 5: ...12 24x1 Flat Head Combo Screw Frame Optional Strike Box Prepare Frame Install Strike This prep is standard with or without deadbolt Use 3 Philips head screwdriver 3 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 6: ...o not tighten screws until Step 10 Make sure mortise pocket is free from debris x2 Inside of Door 12 24x1 Flat Head Combo Screw Mortise Lock Cable Hole Use 3 Philips head screwdriver 4 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 7: ...before installing the cylinder Outside of Door 2 1 Then use 2 Philips head screwdriver to tighten cylinder set screw First tighten cylinder until snug against door with the Yale logo horizontal Outside of Door 1 Use 2 Philips head screwdriver HAND TIGHTEN Do not use powered screw driver 5 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 8: ...lengths to ensure proper installation Install Rose Trim all types Outside of Door Inside of Door 8 32x1 Pan Head Screw with Thread Locker For 1 3 4 Door x2 Use 2 Philips head screwdriver If provided If provided Tighten screws securely but avoid overtightening and warping door 6 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 9: ... of Door 1 2 3 Prepare Levers Inside Lever Correct Orientation Pushing levers together use hex wrench to tighten set screw securely against spindle Loosen Inside Spindle 1 2 to 1 turn until Correct Orientation 7 8 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 10: ...Oval Head Screw x2 Inside of Door Use 2 Philips head screwdriver 9 Test Operation 80 9086 0030 010 04 21 Part of ASSA ABLOY Deadbolt retracts and extends by thumbturn and key Once extended it will also retract by lever Latchbolt retracts and extends by levers and key ...

Page 11: ...n lockbody screws before installation of front Do not bow front of lock case by overtightening Outside of Door Yale logo will be at top and visible when installed Use 2 Philips head screwdriver Test Operation Again 10 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 12: ...Install Keypad Inside of Door 12 11 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 13: ...ropriate for your door thickness Install Inside Mounting Plate 10 32x3 4 Pan Head Screw with Washer For 1 3 4 Door x2 Inside of Door 3 32 Hex Wrench Use 2 Philips head screwdriver 12 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 14: ...14 Attach Cables to Inside Lock Cables must be clear of all fastener holes Inside of Door 13 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 15: ...15 Install Inside Lock 8 32x3 8 Pan Head Screw Black x3 Inside of Door Use 2 Philips head screwdriver 14 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 16: ...tra Key module must be installed BEFORE batteries See Installation Options Welcome to Yale Congratulations you ve installed the Yale nexTouch Keypad Access Sectional Mortise Lock Continue to customize your product 15 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 17: ...le to existing unit Network or Yale Accentra Key Module Installation Options O optional 80 9086 0030 010 04 21 Part of ASSA ABLOY The Yale Accentra Key module enables access with physical cards and fobs and mobile credentials ONLY Creation and use of User PIN codes are disabled ...

Page 18: ...en Keypad 9Volt Battery Override Terminal Lockout Mode Indicator Touchscreen Unlock Indicator Touchscreen Indicator Light Lock Activation On Touchscreen model touch Yale logo to wake lock Lock Activation On Push Button model touch check mark to wake lock 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 19: ...not possible until this step has been successfully completed Press Press Register Master Code Press the gear key to continue Enter a 4 8 digit PIN code Press the gear key to continue Registered Deadbolt Installed Press 1 No Deadbolt Press 3 Press Press Press Touchscreen Press Push Button Enter 4 8 digit Master PIN Code Completed 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 20: ...Press the gear key to continue Press 1 Press Register User code Press the gear key to continue PIN code registration Enter a 4 8 digit PIN code Press the gear key to continue Menu Mode enter number Press Touchscreen Press Push Button 80 9086 0030 010 04 21 Part of ASSA ABLOY The Yale Accentra Key module enables access with physical cards and fobs and mobile credentials ONLY Creation and use of Use...

Page 21: ...t PIN code Press To end programming Press Completed Registered Press the check key to complete Press the gear key to continue Registered Press the check key to complete Press the gear key to continue Enter 4 8 digit PIN code followed by OR 80 9086 0030 010 04 21 Part of ASSA ABLOY ...

Page 22: ...rivacy Mode press and hold Privacy Button Press Touchscreen Press Push Button OR 80 9086 0030 010 04 21 Part of ASSA ABLOY The Yale Accentra Key module enables access with physical cards and fobs and mobile credentials ONLY Creation and use of User PIN codes are disabled Master PIN code is only used for programming and configuring lock with Yale Accentra Multi Family configuration app and will not...

Page 23: ...utton for 3 seconds 6 While continuing to press the reset button temporarily remove one 1 AA battery 7 Reinstall the battery 8 Release reset button and wait approximately 15 seconds Speaker will announce Welcome to Yale 9 Reassemble inside lock 10 If utilizing a network module remove batteries Insert Module Reinstall batteries When lock is reset to factory defaults all user codes including the Mas...

Page 24: ...e Setting With the optional Network Module installed this setting becomes available Main Menu selection 7 and allows the lock to connect with a network controller One Touch Locking When the unit is unlocked activating the keypad will lock the unit during Automatic Re lock duration or when Automatic Re lock is disabled When One Touch Re lock is not in use disabled any valid PIN code will re lock th...

Page 25: ... Configure Deadbolt Eco Mode Continue Complete U Delete A Code Feature Programming Through Menu Mode Using Master PIN code Volume Setting Language Setting All Code Lockout Network Module Setting Advanced Lock Settings This function appears only with Yale Z Wave network module installed Default settings inbold Set up Digital Keys Disable Automatic Re lock Disable One Touch Locking Enable Disable 1 1...

Page 26: ...ve or process will have to be restarted Master user creates manages User and Passage PIN codes PIN code may already be registered Batteries do not have enough power Replace batteries Check that cables are fully connected on inside lock and not crimped Replace batteries Touchscreen models become active when Yale logo is pressed Push Button models become active when key is pressed The digits entered...

Page 27: ...Privacy Mode Disabled Language Setting English Wrong Code Entry Limit 5 Times Shutdown Time 60 Seconds The Master PIN code must be registered prior to any other programming of the lock Volume Setting High All Code Lockout Disabled Escape Return Mode Disabled Inside Indicator Light Enabled 80 9086 0030 010 04 21 Part of ASSA ABLOY 27 ...

Page 28: ... device must accept any interference including interference that may cause undesired operation of the device L émetteur récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d Innovation Sciences et Développement économique Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 L appareil ne doit pas produi...