Delayed Egress
Installation Instructions
Exit Device
Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc.
All rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
10
Operating Instructions
Figure 11
There are three (3) modes of operation:
• Delayed Egress
• Momentary Egress
• Bypass (Maintained) Egress
Delayed Egress Mode
1. Apply power to device.
2. Solid red LED will illuminate.
3. Device is now armed, which will not allow touchpad to retract latchbolt for immediate egress.
4. If device is not functioning, refer to Troubleshooting Guide.
Momentary Egress Mode (Figure 16)
1. With device armed, rotate key counter clockwise and return to center position (remove key).
2. Red LED will flash quickly. Device will release for momentary egress for 10 seconds (factory set).
This can be set to 20 seconds by removing J8 jumper.
3. After 10 (or 20) seconds has elapsed, device will rearm itself.
4. Device will now be back in delayed egress mode.
Bypass (Maintained) Egress Mode (Figure 16)
1. Rotate key clockwise, return key to center position and remove.
2. Red LED will flash slowly.
3. Device is disarmed, acting as a standard exit device which allows free egress.
Resetting device from Bypass Mode to Delayed Egress Mode (Figure 16)
1. Rotate key counter clockwise, return to center position and remove.
2. Solid red LED will illuminate.
3. Device will be in delayed egress mode.
Delayed Egress Operation When Armed
Exit door is normally closed and latched. Delayed Egress device secures door in locked mode with solid
red LED indicating locked mode status. Depressing pushpad for two (2) seconds or less will sound
device nuisance beep without initiating alarm. Depressing pushpad longer than three (3) seconds will
initiate an irreversible local audible beeping tone and a visual amber indicator. After delay time (15 or
30 seconds) releases LED changes to green and siren changes to a steady tone which continues to
alarm until reset. Remote monitoring contact outputs can be used to alert security personnel. Person
depressing exit bar is denied egress for 15 or 30 seconds (depending upon setup) and security
personnel are alerted.
NOTE: For 30 second delay and auto rest, BOCA option is required. Consult authority having
jurisdiction for local code requirements.
Momentary/
Reset
Bypass/
Maintained
LHR
Shown