Presentation of notes and warning signs

Various symbols and texts are used in this manual for easier understanding and identification.

Note! When you see Note! it contains useful advice and information to ensure correct and compliant
usage of the system.

Potential hazardous situation that can lead to either minor or severe injuries
or death and cause either minor or substantial property damage.

Potential hazardous situation that could lead to danger of electric shock and
cause serious injury or death.

Instructions for safe operation

• Failure to observe the information in this manual may

result in personal injury or damage to equipment.

• To reduce the risk of injury of persons - use this oper-

ator only with pedestrian doors.

• The mains power supply shall be installed with protec-

tion and an all-pole mains switch with isolating capab-
ility of Category III, shall be installed according to local
regulations.

• Frequently examine the installation for imbalance

where applicable and signs of wear or damage to
cables, springs and mounting. Do not use if repair or
adjustment is necessary.

• Do not use the equipment if repair or adjustment is

necessary.

1020882-en-5.0

Issue 2022-03-16

4

Summary of Contents for SL300

Page 1: ...Original instructions User Manual Entrance Systems Sliding Door Operator ASSA ABLOY SL300 assaabloyentrance com ...

Page 2: ...Locking 10 Unlocking 10 Operation mode selectors 10 PSK 6U Modes 11 Integrated safety 11 Safety system with presence sensors 12 Technologically advanced sensors 13 How to check inner and outer combined motion and presence detection sensors 14 How to check side presence detector s 14 Safety system with photocells 14 Battery unit 15 Regular safety checks 18 Safety accessories 18 General accessories ...

Page 3: ...0 ASSA ABLOY as word and logo are trademarks owned by the ASSA ABLOY Group ASSA ABLOY Entrance Systems 2022 Technical data subject to change without notice Backtrack information folder Workspace Main version a705 Date 2021 11 30 time 01 59 33 state Frozen 3 Issue 2022 03 16 1020882 en 5 0 ...

Page 4: ... injury or death Instructions for safe operation Failure to observe the information in this manual may result in personal injury or damage to equipment To reduce the risk of injury of persons use this oper ator only with pedestrian doors Themainspowersupplyshallbeinstalledwithprotec tionandanall polemainsswitchwithisolatingcapab ility of Category III shall be installed according to local regulatio...

Page 5: ...tal capacity if they have been instructedbyapersoninchargeoftheirsafetyconcern ing use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance shall not be made by children Do not let children or anyone climb on or play with the door or the fixed remote controls Thedoorsetcanbeoperatedautomaticallybysensors or manually by activators Do not dash through a cl...

Page 6: ... Ensure that controls that can be set for a locked posi tion are only activated when there are no other per sons in the room 1020882 en 5 0 Issue 2022 03 16 6 ...

Page 7: ...ning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna Relocate the receiver with respect to the equipment Move the receiver away from the equipment Plug the receiver into a different outlet so that equipment and receiver are on different branch circuits Check that protective earth PE is conne...

Page 8: ...of power and defects or delays in deliveries by sub contractors caused by any such cir cumstances Please note Non compliance with manufacturers care and maintenance recommendations may void the warranty ASSA ABLOY Entrance Systems authorized resellers shall extend this warranty to end users only buthavenoauthoritytoextendagreaterordifferentwarrantyonbehalfofASSAABLOYEntrance Systems A service agre...

Page 9: ...OY SL300 Type 100 V AC 10 to 240 V AC 10 50 60 Hz fuse 10 AT building installa tion Mains power supply Max 200 W Power consumption IP20 Degree of protection Sound pressure Third party approvals from established certification organizations valid for safety in use Approvals How the ASSA ABLOY SL300 works TheASSAABLOYSL300workselectromechanically Thedriveunit controlunit transmission optional battery...

Page 10: ...raffic passage from inside only The door is normally lockedifanelectromechanicallockingdevicehasbeenfitted The door can only be opened with the inner activation unit or with a key switch if fitted EXIT ONE WAY Thedoorisclosedandlocks ifanelectromechanicallockisfitted Thedoorcannotbeopenedwithinnerandouteractivationunits The door can be opened partially with a key switch if fitted OFF Turn the key ...

Page 11: ...f an obstruction is detected while the door is opening the doors stop immediately and then close after a time delay Safety system with presence sensors Usuallythesafetysystemincorporatespresencesensorsinstalledabovethedooropening Apresence sensor detects an object in the doorway while the doors are closing the doors reverse immediately The doors will start to close when the object is removed 11 Is...

Page 12: ...s These presence sensors further improve the already high obstruction detection obtained with the built in self monitored crush force limitation Monitored sensors have built in monitoring for error detection If you have a problem you cannot correct turn off the automatic door immedi ately and call your ASSA ABLOY Entrance Systems service representative for as sistance 1020882 en 5 0 Issue 2022 03 ...

Page 13: ...you are about 1 5 meter from the door and the door shall stop in open position 2 When the door has closed repeat the same procedure from the other side of the door opening 3 Open the door stand still close to the face of the open door leaf on the left side for more than 5 s The door shall remain open Repeat on the right side 4 Repeat step 3 in the other side of the door opening 1 5 m 1 5 m ILL 016...

Page 14: ...ctivate the impulse on the operator the door shall not stop but slow down to safe speed during the opening If you have a bi parting double door then repeat the procedure above on the other side Safety system with photocells Alternativelythesafetysystemcanincorporatepresencephotocellsinthedooropening Ifanobject is breaking the infrared invisible beam between the photocell units while the doors are ...

Page 15: ...on of glazing rubbers 6 finger protection 7 proper operation closes slowly and smoothly any ventilation being obstructed Set the mode selector to OFF and check that the operator and electromechanical lock if fitted work together Also check that the lock 8 really secures the door Activate the manual activation units 9 if any and walk towards the door Check that the door has opened appropriately whi...

Page 16: ...riod The cleaning should be documented To avoid damages to the profiles the brushes weather stripping must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both aluminium and glass are sensitive to alkalis Do not clean with high pressure water Operator mode selector and sensor may be damaged and water may enter the profiles Do not use polishing detergent Do not scrub wit...

Page 17: ...ERING KONTROLL xxxxxxx xxxxxxx If problem occurs Action Check that all required signage is applied and intact Mandatory indicates that the signage is re quired by European directives and equivalent national legislation outside the European Union Product label Mandatory A ASSA ABLOY Entrance Systems door sticker Mandatory if applicable to highlight the presence of the glass applied to all glass sec...

Page 18: ...e setting of the mode selector The motor does not start Check the mains power and fuse in the building Unlock the mechanical locks The motor starts but stops during opening Clean the floor guide Check for objects jammed under the door The door does not close Change the setting of the mode selector The motor does not start If a presence sensor is installed check for and remove objects placed in the...

Page 19: ...LOY Entrance Systems representative to learn more about our service offering Abusive Environment Cycles hour in operation Part 100 100 10 High traffic Medium traffic Low traffic 24 24 24 24 Battery 12 12 24 36 Door carriage 36 48 48 48 Tooth belt 24 24 24 24 Door stop 36 36 36 36 Tension wheel 60 60 60 60 Detachment guard Other products from ASSA ABLOY Entrance Systems Vertical lifting fabric door...

Page 20: ...019 Other standards or technical specifications which have been applied IEC 60335 1 ed 5 2010 IEC 60335 2 103 ed 2 1 2011 DIN 18650 1 2010 Certificate issued by a notified or competent body for full address please contact ASSA ABLOY Entrance Systems AB concerning the equipment B 08490 20 B 058029 0043 The manufacturing process ensures the compliance of the equipment with the technical file The man...

Page 21: ......

Page 22: ...AlbanyandMegadoor brands we offer our solutions under the ASSA ABLOY brand Our products and services are dedicated to satisfying end user needs for safe secure convenient and sustainable operations ASSA ABLOY Entrance Systems is a division within ASSA ABLOY assaabloyentrance com ASSA ABLOY Entrance Systems Tel 46 10 47 47 000 info aaes assaabloy com assaabloyentrance com ...