![Assa Abloy Sargent PR100 Installation Instructions Manual Download Page 20](http://html.mh-extra.com/html/assa-abloy/sargent-pr100/sargent-pr100_installation-instructions-manual_2988459020.webp)
20
Copyright © 2012, Sargen
t Manufacturing Company
, an A
SS
A AB
LO
Y G
roup company
. All right
s reser
ved
.
Reproductions in whole or in par
t without express writ
ten permission of Sargen
t Manufacturing Company is prohibited
.
8/05/12
PR100 Exit Devices
1. Attach escutcheons to the door after wires are connected.
2A. For 12- fire rated devices:
Feed keypad ribbon cable/
connector from outside of door through gasket
and fire stop plate (Fig. 10).
2B. For non-12- exit devices:
Feed keypad
ribbon cable/connector through the
gasket and then through the conduit
hole in door (not shown).
Note: Install ribbon cable with cable exiting down.
3. Place the outside escutcheon against the door,
while directing mounting posts through the door.
9 Install Gasket (for Exterior Doors)
For exterior applications, use a gasket between escutcheon and
outside door surface.
To apply weatherseal gasket:
1. Carefully remove the backing from the gasket (Fig. 9).
2. Apply gasket to escutcheon:
a. Starting in one place, press the
adhesive side of the gasket
firmly against the escutcheon.
b. Work around the escutcheon,
pressing the sticky side of the
gasket firmly against the
escutcheon edge.
c. The gasket should be aligned so
that all edges of the escutcheon
are covered.
Fig. 9
Fire
Stop
Plate
Weatherseal
Gasket
Fig. 10
Reader
Cable
10 Install Outside Escutcheon