background image

Copyright © 2012, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved. 

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

12/30/12

1          A8094B

S1/S2 Replacement Controller Instructions

52-4424, 52-4425, 52-4533, 52-4537

FOR INSTALLATION ASSISTANCE CONTACT SARGENT • 1-800-810-WIRE (9473) • www.sargentlock.com

1.

   On the inside of the door, remove the security screw from the battery   

      cover on the inside escutcheon (Fig. 1).

2. 

  Lift and remove the battery cover (Fig. 1). 

This controller has been configured as a generic replacement. 

The serial number MUST be changed before it can be used!

(For serial configuration, refer to 

Step 2 - Configure Serial Number

 )

NOTE: 

For S2 Controllers previously labeled 52-4426, use 

52-4425

 for the   

            replacement controller part number.

1 - Replace Controller

Fig.  1

6.

  Remove inside escutcheon assembly from door.

3a.

 For exit devices, continue to Step 4 (the inside lever handle does  

      not need to be removed in order to change the controller).

3b.

 For a cylindrical lock, remove the inside lever handle by inserting  

      the push-pin tool (provided with lock) as shown in Figure 2A.

3c. 

For a mortise lock, remove the inside lever handle by loosening  

      the lever handle set screw (Fig. 2B).

4.

   Remove top and bottom through-bolts from inside escutcheon. 

5.

   Carefully separate escutcheon slightly from door and disconnect            

      antenna (iCLASS only), gray ribbon reader cable, green grounding wire,               

      motor harness, DPS harness (Fig. 2C), and hard-wired harness/PoE (if present). 

Set Screw

Fig.  2B

Inside Lever

Inside of door

Push-Pin Tool

Fig.  2A

Fig.  2C

Summary of Contents for Sargent 52-4424

Page 1: ... Configure Serial Number NOTE For S2 Controllers previously labeled 52 4426 use 52 4425 for the replacement controller part number 1 Replace Controller Fig 1 6 Remove inside escutcheon assembly from door 3a For exit devices continue to Step 4 the inside lever handle does not need to be removed in order to change the controller 3b For a cylindrical lock remove the inside lever handle by inserting t...

Page 2: ... controller in place Fig 3 Remove controller 7 Seat the replacement controller into inside escutcheon Attach with the four 4 original Phillips screws 8 Reconnect the keypad harness ground wire DPS harness motor harness and hard wired PoE harness if present See Figure 4 9 Mount the inside escutcheon back on the door using the two through bolt screws Fig 4 Reattach lever if applicable 10 Install bat...

Page 3: ...t Controller Instructions 52 4424 52 4425 52 4533 52 4537 1 Using Lock Configuration Tool LCT connect to the new controller 2 From the main drop down Fig 6A select Configure Serial Number 3 Click Go 2 Configure Serial Number 6 Click Apply Serial Number S N 7 Configure lock as usual 8 Replace battery cover and install security screw Fig 6B Configure Serial Number Fig 6A 4 Select the correct reader ...

Page 4: ...ny is prohibited FOR INSTALLATION ASSISTANCE CONTACT SARGENT 1 800 810 WIRE 9473 www sargentlock com S1 S2 Replacement Controller Instructions 52 4424 52 4425 52 4533 52 4537 1 Attach battery cover to inside escutcheon making sure to line up tabs with retaining slots in battery cover 2 Secure with the security screw and tool P N 01 0297 Fig 7A Security Tool Retaining slots Tabs Fig 7A 3 Replace Ba...

Reviews: