1. Prepare door and frame.
3a. Remove dial
from foot.
4. Connect arms, preload spring
and tighten screw.
3b. Install separate arms.
You’ve installed the
351 Hold Open Closer - Standard Mount.
🛑
Go to page 7 for closer adjustments and cover installation.
Dial DOWN
Left and Right Hand
RH and LH:
Position index at 2
1st
2nd
3rd
1st
3rd
2nd
Rotate elbow until
Foot Assembly arm
is perpendicular to
frame.
Rotating Main arm
preloads closer
spring power.
RH:
Clockwise
to tighten.
LH: Counter
clockwise to
tighten.
1st
3rd
2nd
5. Set Hold Open.
Keep door open in position
until dial screw secures dial.
Arm Type Mounting Max Door
Opening
**Dim A
**Dim B
H
Holder
Standard
110°
9-1/2"
(241)
12-3/4"
(324)
Alternate
*160°
6-1/2"
(165)
9-3/4"
(248)
NOTES:
1. IMPORTANT: Use Alternate mounting if door can open
beyond limits shown for standard mounting.
2. *If butt, frame, and wall conditions permit, door will open
180°.
3. ** Dimension is taken from hinge edge of door for
invisible hinges. Butt, offset, swing clear, center hung or
invisible hinges.
4. Use screws provided or use mortise nuts when required.
See chart on page 2.
2. Mount case to door.
Secure arms
with Swivel
Arm Screw.
LH and RH:
Spring Adjustment Screw AWAY from hinge
Closer is stamped RH at top for right hand
doors and LH at top for left hand doors.
351 Standard Mount - H Arm Installation
(Right Hand Shown)
Approved 2020-01-21