Included with Pull Side or Double Egress

Included with Push Side

Push Side

Arm Assembly

Arm Screw

Certifications

Track End
  Cap (2)

Slide Assembly

Track Cover

Pull Side Arm

Slide Track

Double Egress
Pull Side Arm (Handed)

Track Mtg
Screw (2)

Cushion Stop
Assembly

4 (Non-Detectored)

Cover

Cover Mtg
Screw (6)

Closer/Holder Unit Assembly

(Handed)

Backplate

Power Supply
(120V units only)

Backplate
Mtg Screw (4)

Test/Power
    Switch

 

 

  
 
9/32” (7 mm) thru;
3/8” (9.5 mm) dia. x
3/8” (9.5 mm) deep on
door opposite to closer

Standard

Optional

Through-bolts and

grommet-nuts

All

Preparation for Fasteners

Door or Frame

Fasteners

Drill-Sizes

1/4” - 20 machine

screw

Metal 

Pre-Drill: 9/64 hole 

Sleeve nuts and

bolts

(Shoe screws only)

Hollow

Metal

9/32” (7 mm) through;
3/8” (9.5 mm) door face
opposite to closer

Aluminum

or Wood

3/8” (9.5 mm) through

Self tapping screw

(Track screws only)

Drill: #7 (0.201” dia.)
Tap:  1/4” - 20 

Metal / 

Wood 

Self tapping screw

(Closer mounting

screws only)

Metal / 

Wood

Pre-Drill: 3/16 hole 

UL228, UL10B

6 (Dectectored)

Closer/Holder Unit Assembly

(Handed)

Backplate

Power Supply
(120V units only)

Backplate
Mtg Screw (4)

Test/Power
    Switch

Cover

Cover Mtg
Screw (6)

Smoke Detector

General Information

3000 Highway 74 East     Monroe, NC 28112
Tel:

  Fax: (800)-221-0489

www.r ixson.com

(800)-

457-5670

ASSA ABLOY

RI X SON

®

Summary of Contents for Rixson Smok-Chek VI

Page 1: ...rior of building in dry environment maximum humidity of 95 See NFPA70 for wiring requirements and NFPA72 for alarm system requirements Pull Side Applications with Slide Track 4 Pull 6 Pull see page 7...

Page 2: ...ge Of Door DOOR OPENING ANGLE Dim A Inches mm To 100 100 to 180 5 7 8 3 1 8 149 2 79 4 Hinge or Pivot Drill 7 Tap 1 4 20 UNC 19 3 4 1 3 4 44 5 C 4 101 6 11 1 4 285 8 501 7 For Concealed Wiring Only 7...

Page 3: ...g closer body by key hole slots b and slide closer toward hinge to capture screw heads c Warning Do not allow pedestrian traffic through opening until all mounting screws are tightened Closer Mounting...

Page 4: ...er Spring Adjustment 3 8 11 16 Wrench Closing Force Weaker Stronger Slowly increase closer power until door closes consistently A closer set to the ADA required 5 lbs opening force may not be strong e...

Page 5: ...remove valves from closer Hydraulic oil will escape 1 8 Hex Key 1 8 Hex Key w o e l r S F r aste w o e l r S F r aste Weaker Stronger Closing Speed Controls Valve S Controls Sweep Range from full ope...

Page 6: ...d units detectored units cannot be turned off at the closer See previous step Open door to desired hold open angle Loosen cam screw and rotate cam until switch closes and door holds open Rotate cam un...

Page 7: ...oor shown left hand opposite All dimensions shown in inches mm Install two screws in the key slot locations leaving 1 8 gap between screw head and frame as shown a a C 1 8 1 Track Mount Unit 6 152 4 1...

Page 8: ...8 wrench provided Mount closer arm to pinion square as shown Use main arm to rotate pinion until flat is visible RE INSTALL HERE LEFT HAND RIGHT HAND Attach with provided screw and washer Tighten arm...

Page 9: ...r than 125 spring cushion stop cannot be used and an auxiliary stop by others is required Mount Track 3 7 Connect Arm to Track 3 8 Open door to maximum desired swing minus 5 and hold Slide spring cush...

Page 10: ...ves from closer Hydraulic oil will escape 1 8 Hex Key w o e l r S F r aste Weaker Stronger Closing Speed Controls Valve S Controls Sweep Range from full open to 5 Valve L Controls Latch Range from 5 t...

Page 11: ...en position SHO switch in open position Closer not in hold open SHO switch in closed position Closer in hold open Un used pin Setting Hold Open Angle Make all required electrical connections and turn...

Page 12: ...strations below NON DETECTORED ELECTRICAL CONNECTIONS Surface mount power input Remove appropriate shaded area from cover for surface wired installations only Repaint cut edges as necessary to prevent...

Page 13: ...w SMOKE DETECTOR ELECTRICAL CONNECTIONS 120V AC INPUT Surface mount power input Remove appropriate shaded area from cover for surface wired installations only Repaint cut edges as necessary to prevent...

Page 14: ...block or power supply using illustrations below RF REMOTE RECEIVER UNITS ELECTRICAL CONNECTIONS 120V AC INPUT Surface mount power input Remove appropriate shaded area from cover for surface wired ins...

Page 15: ...tton on the receiver depending on the activation requirements If delay learn is selected adjust potentiometer to counterclockwise limit 0 second delay After learn cycle is complete adjust potentiomete...

Page 16: ...tch 9 32 7 mm thru 3 8 9 5 mm dia x 3 8 9 5 mm deep on door opposite to closer Standard Optional Through bolts and grommet nuts All Preparation for Fasteners Door or Frame Fasteners Drill Sizes 1 4 20...

Reviews: