Passport 1000 Series P1 PoE Mortise Lock
Operational Check
9
IMPORTANT
: Be sure to test functions prior to closing door.
In all cases, perform the following checks:
1. Ensure that inside lever retracts latch (and deadbolt for dead-
bolt functions).
• For units with cylinders, the following checks apply:
Insert key into cylinder and rotate:
a. There should be no friction against lock case, wire
harness, or any other obstructions. If friction or bind-
ing occurs, re-adjust cylinder and wiring harness to
eliminate issues.
b. The key should retract the latch and the key should
rotate freely.
c. The key should extend and retract the deadbolt.
• For units without a keypad, add card using LCT
software and test.
• For units with a keypad, add pin and card using LCT
software and test.
2. LED signalling:
• After using a valid credential, a green flash followed by
three fast amber flashes indicates a low power condition.
Check the input voltage.
If the input voltage is low, disconnect the lock from the
power source and check the power source
voltage. If the power source voltage is correct,
inspect the lock wiring for a possible short.
• If the lock loses power, it will flash rapid amber
for approximately one minute.
After that, the lock will no longer be functional.
3. When you have completed the tests, close the door, ensuring
latchbolt and deadbolt fully extend into strike plate without
binding.