Model 704 Wave to Open Switch

 

1-3/4" Wide Jamb Mounting 

Installation Instructions

1/8"

Bit

Phillips

Drive Bit

Drill

Step

Bit

Flat Head

Screwdriver

Phillips Head

Screwdriver

Safety Glasses

Center

Punch

Pencil

Deburring

Tool

Wire Stripper/

Cutter

Tape Measure

This product can expose you to lead which is known to the state of 

California to cause cancer and birth defects or other reproductive harm. 

For more information go to www.P65warnings.ca.gov.

WARNING

Components

Supplied Fasteners

Tools Needed

Conduit supplied by others

This unit is not supplied with a radio frequency transmitter. 

If a transmitter is added, a deeper surface mounted box, 

supplied by others, will be needed.

2x

M3 x 8.3mm Philips 

Flat Head Machine 

Screw

4x

#8 Phillips Round 

Head Metal 

Drilling Screw

Conduit 

Housing

Wave to Open 

Switch

M3 Screw

#8 Screw

Specifications:

Input Voltage: 12V to24VDC
SPDT Contact Rating: 2A @30VAC/VDC
Sensor Detection Range: Up to 4" (101mm)
Operating Temperature: -13° F to 131°F (-25°C to 55°C)
Current Draw: 50mA @12VDC, 65mA @24VDC

Approved 2020-07-09

Summary of Contents for Norton Wave to Open 704

Page 1: ...ead which is known to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov WARNING Components Supplied Fasteners Tools Needed Conduit supplied by others This unit is not supplied with a radio frequency transmitter If a transmitter is added a deeper surface mounted box supplied by others will be needed 2x M3 x 8 3mm P...

Page 2: ...onnection loosen screws fully and ensure silver contact is completely down Insert wires and tighten screws to secure wires 1 Sec 5 Sec 10 Sec 15 Sec 20 Sec 25 Sec 30 Sec 35 Sec LED Setting Time Delay Setting Jumper in place LED is Red and flashes Green when relay is active No Jumper LED is Green and flashes Red when relay is active 3 1 4 mm 83 1 3 4 mm 44 5 15 16 24 2mm 5 8 16mm 1 3 8 mm 34 9 4 1 ...

Page 3: ...stallation Prepare Door Jamb 1 If required by local codes attach wire conduit supplied by others to back of housing and feed wires through 2 Align housing to mounting holes on door jamb and secure with four 4 8 Phillips Round Head Metal Drilling screws Fig 3 NOTE Make sure housing is level Install Conduit Housing 1 Set LED and Time Delay Settings as desired on Wave to Open switch See LED Setting a...

Page 4: ...ort Monroe NC 28112 USA Phone 800 438 1951 ext 6030 TechSupport Norton assaabloy com nortondoorcontrols com Two Modes Standby default LED Red Operating default LED flashing Green To operate switch make a slow waving motion with hand in front of plate within 4 101mm When hand movement is detected or backup button is pressed a tone will sound and LED circle will flash to indicate relay has been acti...

Reviews: