80-9395-9521-020 Rev/1 (06-16)
ASSA ABLOY
Norton is a brand associated with Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2016, Yale Security Inc. All rights reserved. Reproduction in whole or in part
without the express written permission of Yale Security Inc. is prohibited.
Ÿ
An improperly installed or incorrectly adjusted door closer may cause
property
damage
or
personal injury;
and will void product warranty.
Ÿ
To avoid personal injury,
DO NOT DISASSEMBLE THIS DOOR CLOSER BODY.
Ÿ
Door closers must be securely fastened to a properly reinforced door and frame with
fasteners provided.
Ÿ
The Americans with Disabilities Act (ADA) requires that interior doors, other than fire
doors, have an opening force not to exceed 5 lbf as measured 1" from the latch edge
of door; force measurement starting 3" from jamb up to 70° of opening These forces
do not apply to the force required to retract latch bolts or disengage other devices that
hold the door or gate in a closed position.
Ÿ
The door closer's power size adjustment feature may require adjustment to its lowest
setting to comply with ADA opening force guidelines.
Ÿ
Low opening forces result in lower closing forces which are not always acceptable in
closing and latching a door depending on field conditions such as weight of door, hinge
conditions, and or stack pressure.
Ÿ
An auxiliary door stop, by others, is strongly recommended to avoid damage to the
door closer and adjacent property.
Ÿ
Doors should be hung on ball bearing or anti-friction hinges/pivots.
Ÿ
Door closer must not be installed on the exterior side of a door located in an exterior
wall of a building.
Ÿ
ADA compliant closer.
IMPORTANT:
BEFORE
INSTALLING:
TO DETERMINE
HAND OF
YOUR DOOR:
LEFT
HAND
DOOR
RIGHT
HAND
DOOR
RHR
LHR
Size of Door & Door Closer
Type
of
Installation
Interior
Exterior
In-swinging
Exterior
Out-swinging
Recommended
Closer Size
**Max.
Opening
Force
lbs/f
2 4
' "
3 0
' "
3 6
' "
4 0
' "
4 6
' "
5 0
' "
2 4
' "
2 6
' "
3 0
' "
3 6
' "
4 0
' "
4 6
' "
2 6
' "
3 0
' "
3 6
' "
4 0
' "
2 6
' "
3 0
' "
3 6
' "
4 0
' "
3 0
' "
3 6
' "
4 0
' "
4 6
' "
1
2
3
4
5
6
8
14
16
22
24
26
8
14
16
22
24
26
1
2
3
4
5
6
Regular &
Top Jamb
Parallel
Arm
Page 2