background image

Copyright © 2007, 2014 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. 
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited. 

80-9377-1204-020 (04-14)

1

ASSA ABLOY

ASSA ABLOY

Installation Instructions

7500H Series

An incorrectly installed or improperly 

adjusted door closer can cause property 

damage or personal injury. These instructions 

should be followed to avoid the possibility 

of misapplication or misadjustment.

CAUTION

 Hold Open Door Closers

Models – 7500-H

J7500-H

JL7500-H

P7500-H

Note:  

Multi Size - 1 thru 6

Closer mounts on hinge (pull) side of door. 

See Page 3.

Closer cover not shown

Regular Arm Installation

 Right Hand Door - RH

Left Hand Reverse - LHR

 Left Hand Door - LH
 Right Hand Reverse - RHR

Top Jamb Installation

Closer mounts on frame face on opposite to hinge (push) side of door. 

See Page 4.

Closer cover not shown

 Right Hand Door - RH
 Left Hand Reverse - LHR

 Right Hand Door - RH
 Left Hand Reverse - LHR

 Hinge Edge

of Door

 Hinge Edge

of Door

 Hinge Edge

of Door

 Hinge Edge

of Door

 Left Hand Door - LH

 Right Hand Reverse - RHR

 Left Hand Door - LH

 Right Hand Reverse - RHR

Parallel Arm Installation

Closer mounts on opposite to hinge (push) side of door.

See Page 5.

Closer cover not shown

The closing force for series 7500 door closer is adjustable from a size 1 to a size 6, as outlined
in ANSI Standard A156.4. When this series of door closer is installed and adjusted to conform to
ADA reduced opening force requirements (5 lbs max.) for interior doors, it  may not have adequate 
closing force to reliably close and latch the door. Power adjustments charted on pages 3,4 and 5
are recommended where possible, to ensure proper door control.