Standard Function with Switches
1
2
3
4
1
2
3
4
Notes:
1. Power input to Door Operator Unit
is at “T1” Power Input Terminal (not
shown) 120VAC 60Hz.
Wall Switch, Card
Reader, Key Switch,
etc.
1
2
3
4
1
2
3
4
Door 1
Door 2
Inverter Adjustments:
Based on function
adjustment desired,
use table above to
determine which POT
is to be adjusted.
POT
FUNCTION
DESCRIPTION
OBSTR SENS
Obstruction Detection on Open
CW - Increase
CCW - Decrease
M/DLY
Motor Delay on Opening
CW - Increase
CCW - Decrease
P1
Closing Speed
CW - Increase
CCW - Decrease
H/O TM
Hold Open Time (5 - 30 Seconds)
CW - Increase
CCW - Decrease
P2
Opening Speed
CW - Increase
CCW - Decrease
H/O TQ
Motor Torque at Hold Open
Position
CW - Increase
CCW - Decrease
ON
1
2
WARNING
120 HIGH VOLT POTENTIAL PRESENT. MAKE
SURE POWER IS TURNED OFF DURING
INSTALLATION PROCEDURE.
Dip Switch Settings
1. Door Mounting -
2. Push Recognition -
ON - pull
OFF - push
ON - active
OFF - inactive
WARNING
Electric
Shock Risk
Operation:
Doors are normally closed.
Activating either switch will open both doors. Door will
close after hold open time delay has elapsed.
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
L2
115Y
L1
115/230VAC IN
MOTOR OUT
L2
230Y
U
V
W
STATUS LEDS
H/O TQ
H/O TM
OBSTR
SENS
P1
M/DLY
P2
1
6
COM
SNS
COM
PB
K1
K2
11
JMP503
NC
NO
TB501
PULL PUSH
SW501
ON
1
2
Inverter Details
Page 9
Wall Switch, Card
Reader, Key Switch,
etc.
Normally Open Momentary
dry contacts
Normally Open Momentary
dry contacts