background image

Copyright © 2016, 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole 

or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.

80-9316-2533-020  Rev 2  02/20

4

1600 UniTrol Arm Installation 

(Right Hand Shown)

2.   Close latch and 

sweep valves.

3.   Install arm to frame.

S

L

5.   Rotate closer pinion to align flat as shown.

S and L valves 

AWAY from hinge

1.   Prepare door and frame.

1.  Be sure that arm is correct for door width.  

See “Components” on page 1. 

2.  Be sure that correct frame and door template 

combination is used to prepare for installation. 

See “Templates” on page 3. 

3.  Using dimensions for hold-open or door stop 

angle desired, mark and drill

•  Four (4) holes on door for closer (or drop 

plate)  

• 

Six (6) holes on frame for soffit plate and 6190 

bracket (See Figure 1) or 

 

• 

Four (4) holes on frame for soffit plate and 

6191 reinforcing kit (See Figure 2) or 

•  Four (4) holes on frame for 2022 angle bracket 

(See Figure 3) 

4.  UNI1601 ONLY: Set approximate closing power 

using “Spring Power Adjustment” chart on page 5.

To ease optional cover 

installation, insert cover 

screws onto closer 

(leaving a slight gap) 

before mounting closer. 

Figure 1.  1-7/8" - 4-5/8" Standard Frame With 6190 Bracket

Figure 2.  Over 4-5/8" Deep Reveal With 6191 Reinforcing Kit

Figure 3.  Flush Transom With 2022 Bracket

4.   Mount drop plate (if used) and closer.

Standard Frame - 6190 Bracket

Deep Reveal - 6191 Kit

Flush Transom - 2022 Bracket

Reviews: