Copyright © 2016, 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9316-2533-020 Rev 2 02/20
4
1600 UniTrol Arm Installation
(Right Hand Shown)
2. Close latch and
sweep valves.
3. Install arm to frame.
S
L
5. Rotate closer pinion to align flat as shown.
S and L valves
AWAY from hinge
1. Prepare door and frame.
1. Be sure that arm is correct for door width.
See “Components” on page 1.
2. Be sure that correct frame and door template
combination is used to prepare for installation.
See “Templates” on page 3.
3. Using dimensions for hold-open or door stop
angle desired, mark and drill
• Four (4) holes on door for closer (or drop
plate)
•
Six (6) holes on frame for soffit plate and 6190
bracket (See Figure 1) or
•
Four (4) holes on frame for soffit plate and
6191 reinforcing kit (See Figure 2) or
• Four (4) holes on frame for 2022 angle bracket
(See Figure 3)
4. UNI1601 ONLY: Set approximate closing power
using “Spring Power Adjustment” chart on page 5.
To ease optional cover
installation, insert cover
screws onto closer
(leaving a slight gap)
before mounting closer.
Figure 1. 1-7/8" - 4-5/8" Standard Frame With 6190 Bracket
Figure 2. Over 4-5/8" Deep Reveal With 6191 Reinforcing Kit
Figure 3. Flush Transom With 2022 Bracket
4. Mount drop plate (if used) and closer.
Standard Frame - 6190 Bracket
Deep Reveal - 6191 Kit
Flush Transom - 2022 Bracket