Copyright © 2016, 2020, ASSA ABLOY Accessories and Door Controls Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Accessories and Door Controls Group, Inc. is prohibited.
80-9316-2533-020 Rev 2 02/20
5
1600 UniTrol Arm Installation
(Right Hand Shown)
6. Attach arm to closer.
7. Open latch and sweep valves.
S
L
Do not completely
open valves. Valves
will leak.
You’ve now installed the
1600 UniTrol Arm Closer.
🛑
Continue with closer adjustments and decorative cap or cover installation.
RH: Position flat at R
LH: Position flat at L
Closer Adjustments
Latch
Backcheck
Use provided 1/8" hex wrench to
turn valves.
NEVER force valves out of closer.
NEVER completely close
backcheck valve. Backcheck
is not a positive stop.
Door must be open to adjust
spring closing power. Refer to
chart.
Do not use a power drill.
Warranty will be void.
Sweep
Do not over tighten
cap or cover screws
Pinion Cap or Cover
Screw pinion cap onto pinion
shaft by hand or with a Phillips
screwdriver.
OR
Slide cover over closer and secure
mounting screws after installation
is complete.