Assa Abloy medeco Aperio M100 Installation Instructions Manual Download Page 6

 

 

Fig. 4 

Screw the M100 into the cylinder mounting hole on the mortise hardware (Fig. 5).  It is important to not 
over tighten, or to keep too loose on the door. The face of the M100 cylinder should stand proud of the  
escutcheon approximately 3/16"-1/4".  Please also see (Fig. 12) before proceeding (Fig. 6). 
 

                           

 

Fig. 5                                                                                                                                   Fig. 6                                        

   

 

Step 3: 

Re-tighten the cylinder clamp screw with the M100 in a vertical position.  The screw should 

engage tightly in the slot along the edge of the cylinder so the cylinder cannot rotate (Fig. 7). 

 

Fig.

 

7

 

 

Step 4: 

Add back plate and locking nut (Fig. 8). 

Warning:

 Wire harness goes through plate (Fig. 9). 

Summary of Contents for medeco Aperio M100

Page 1: ...2 4 GHz IEEE 802 15 4 using AES 128bit encryption Hub Power Requirement 8 24VDC 250mA Lock Battery Type CR2 providing 30 000 Cycles Operating Temperature 10C to 50C FCC Part 15 Class B Compliant Crede...

Page 2: ...to an access control system through the included communication hub The communication hub connects to the access control system with wiegand wiring typical of a wiegand reader When a credential card is...

Page 3: ...ference For a stable and reliable radio link it is recommended that the hub is located within forty five 45 feet of the lock A maximum of two interior walls between the hub and lock is recommended Rec...

Page 4: ...includes three form C relays that can be used to transmit Lock jamb status low battery signal and a tamper signal The hub connects to the mortise lock wirelessly Note the Green LED input is used to gr...

Page 5: ...ents to function properly with the mortise hardware The following steps outline the mechanical installation only Removal of Existing Cylinder a Remove the door edge trim by removing the retaining scre...

Page 6: ...proud of the escutcheon approximately 3 16 1 4 Please also see Fig 12 before proceeding Fig 6 Fig 5 Fig 6 Step 3 Re tighten the cylinder clamp screw with the M100 in a vertical position The screw sho...

Page 7: ...Only one or two threads should be visible for proper operation Fig 11 Fig 10 Fig 11 Step 5 Connect control unit to wire harness and install 4 mounting screws Fig 12 and Fig 13 Warning Avoid pinching w...

Page 8: ...ase verify the battery is inserted in the correct polarity position Always use new batteries installed with correct polarity Fig 14 and 15 Fig 14 Fig 15 Step 7 Install cover assembly Fig 16 and cover...

Page 9: ...nterference that may cause undesired operation Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equipment Le pr sent appareil est con...

Page 10: ...rn is not out far enough refer to Step 4 Fig 12 The cover does not sit flush on plate Cylinder is protruding out to far included are optional spacers for proper spacing of cylinders refer to Step 4 Fi...