Assa Abloy medeco Aperio M100 Installation Instructions Manual Download Page 3

 

 

 

Installation Steps 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

A. 1 - Choose the hub location 

It is recommended that the hub be mounted near the top of a wall, on the ceiling or 

above the ceiling to reduce potential for interference. 
 
For a stable and reliable radio link, it is recommended that the hub is located within forty-five (45) 
feet of the lock.  A maximum of two interior walls between the hub and lock is recommended 
 
Recommended locations: 

A: Wall Mount 
B: Ceiling Mount 
C: Inside Ceiling Mount 
D: Wall Mount, Adjacent Room 

 
 
  

 
 

 

C. Test the Lock 

A. Locate and Mount the Hub 

B. Connect the Hub 

D. Install the Lock 

Summary of Contents for medeco Aperio M100

Page 1: ...2 4 GHz IEEE 802 15 4 using AES 128bit encryption Hub Power Requirement 8 24VDC 250mA Lock Battery Type CR2 providing 30 000 Cycles Operating Temperature 10C to 50C FCC Part 15 Class B Compliant Crede...

Page 2: ...to an access control system through the included communication hub The communication hub connects to the access control system with wiegand wiring typical of a wiegand reader When a credential card is...

Page 3: ...ference For a stable and reliable radio link it is recommended that the hub is located within forty five 45 feet of the lock A maximum of two interior walls between the hub and lock is recommended Rec...

Page 4: ...includes three form C relays that can be used to transmit Lock jamb status low battery signal and a tamper signal The hub connects to the mortise lock wirelessly Note the Green LED input is used to gr...

Page 5: ...ents to function properly with the mortise hardware The following steps outline the mechanical installation only Removal of Existing Cylinder a Remove the door edge trim by removing the retaining scre...

Page 6: ...proud of the escutcheon approximately 3 16 1 4 Please also see Fig 12 before proceeding Fig 6 Fig 5 Fig 6 Step 3 Re tighten the cylinder clamp screw with the M100 in a vertical position The screw sho...

Page 7: ...Only one or two threads should be visible for proper operation Fig 11 Fig 10 Fig 11 Step 5 Connect control unit to wire harness and install 4 mounting screws Fig 12 and Fig 13 Warning Avoid pinching w...

Page 8: ...ase verify the battery is inserted in the correct polarity position Always use new batteries installed with correct polarity Fig 14 and 15 Fig 14 Fig 15 Step 7 Install cover assembly Fig 16 and cover...

Page 9: ...nterference that may cause undesired operation Changes or modifications not expressly approved by the manufacturer could void the user s authority to operate this equipment Le pr sent appareil est con...

Page 10: ...rn is not out far enough refer to Step 4 Fig 12 The cover does not sit flush on plate Cylinder is protruding out to far included are optional spacers for proper spacing of cylinders refer to Step 4 Fi...