LCU9101 

Description of the board 

 

0

006

8e
30
07
5f

00

06

8e

30

07

5f

WDG

A
B

C
D

 

Over load 12V Out

Over load RE1 12V Out

CL reader connected

RE 1

RE 2

 

 

 

Summary of Contents for LCU9101

Page 1: ... the board 6 Indications 7 Settings with DIP switches 8 DIP1 Telnet 8 DIP2 Initiate motor lock 8 DIP3 Balanced door monitor switch 8 DIP4 Fixed IP 192 168 1 250 8 DIP6 Master reset and test mode 8 Installation 9 Installation Relay board DAC400RC64 9 Jumper links 10 Terminal blocks 11 Initiating motor lock 13 Connection of accessories 14 IG559101931C doc ...

Page 2: ...erial parallel 15 PoE Power over Ethernet 16 Configuration 17 Introduction 17 Automatic configuration 17 Conditions 17 Check list 18 Manual configuration 19 Installation of drivers for USB configuration 19 Terminal software 20 Configuration via the terminal software 20 Terminal commands 23 Key handling 26 Technical information 27 Dimensions 28 Diagram 28 ...

Page 3: ...1 contains all that is necessary for the door All connections for e g motor lock reader electric strike exit button door monitor switch alarm door automatic etc are to be made here Compatible accessories Motor lock References to motor lock refers to direct control as follows Assa Classic 8000S 8001S Assa Classic 8087S Abloy 8164 II 8165 II EL650 II Assa Evolution 810S 811S Readers LCU9101 handles ...

Page 4: ...4 LCU9101 LCU9101 ...

Page 5: ...LCU9101 5 LCU9101 with relay board ...

Page 6: ...6 LCU9101 Description of the board 00068e30075f 00068e30075f WDG A B C D Over load 12V Out Over load RE1 12V Out CL reader connected RE 1 RE 2 ...

Page 7: ...control unit have messages to send to the ARX server C Green Receiving data D Green Initiated CL motor lock found OL Overload Lit when the over voltage protection to 12V out pin 12V 0V feeding reader etc is triggered CL Red Lit when readers are connected to the CL CL port 12v Over Red Lit when the over voltage protection to 12V via RE1 NO C is triggered LED RE1 RE2 lit when the relay takes hold Li...

Page 8: ... OFF and replace a possible Learn jumper link on the motor lock DIP3 Balanced door monitor switch DIP3 in position ON and two resistors of 2 2KΩ mounted on the door monitor switch then restart the control unit DIP4 Fixed IP 192 168 1 250 Can be used when you want to set up the control unit with the aid of a TP cable used together with DIP1 DIP6 Master reset and test mode When DIP6 is set to ON the...

Page 9: ...ll outputs and inputs relay board DAC400RC64 must be connected Connection of relay board is made as follows 1 Turn off the power to LCU9101 2 Dislocate LCU9101 from the box 3 Align the contact pieces toward each other 4 Make sure that the boards are in level with each other 5 Push the boards together 6 Snap the boards to the box 7 Turn the power ON LCU9101 RC64 are ready for operation ...

Page 10: ...68e30075f DIP omkopplare DIP1 Telnet ON OFF DIP2 I läge ON initiering motorlås DIP3 Balanserad dörrbladslägeskontakt DIP4 Fast IP 192 168 1 250 DIP5 Används ej DIP6 Master reset samt testläge 12V ut 1 2 12V Ut på relä 1 12V In 1 2 In spänning ut på relä 1 Val av NO NC relä 2 LFK Hi O terminering ...

Page 11: ...0V CL CL Button 0V SW AC DC AC DC 1 15 10 5 Electric strike Electric lock Pin 1 2 ABP Alarm bypass Connection of Hi O bus Feeding to reader and Hi O components Directly connected motor locks and CL readers Exit button Door monitor switch Feeding LCU9101 cannot be fed with 12V ...

Page 12: ...esumed closed when pin 13 is connected to 0V pin 12 and DIP3 OFF DIP3 ON Balanced input on Door monitor see page 8 OK 2 2 kΩ When a direct connected motor lock is connected the input works in parallel with the magnet in the lock LCU9101 must be restarted after selecting DIP3 ON Balanced mode Electric strike 1 2 Coil For function and current see jumper link field on page 9 ABPP 3 4 Alarm ByPass NO ...

Page 13: ...1S Assa Classic 8000S 8001S as from May 04 Assa Classic 8087S as from March 06 With the power off and the bolt in 8 Put all DIP2 switches in ON position 9 Turn the power on when LCU9101 has started and LED D green is lit the motor lock is initiated 10 Turn the power OFF and put DIP2 in OFF 11 Turn the power ON 12 Test run the lock Note When changing LCU9101 an initiation of the motor lock must be ...

Page 14: ...ed Door monitor switch DIP3 ON Balanced IN on SW Resistor of 2 2kΩ is delivered with LCU9101 These are the valid values for the input on LCU9101 12 13 SAB Rin 1 8kΩ OK 1 8kΩ Rin 3 3kΩ ALARM 3 3kΩ Rin 15kΩ SAB Rin 15kΩ This function means that you get the whole chain from alarm central via LCU9101 to door double balanced and the LCU9101 works as a detector See picture below ...

Page 15: ... Night input This means that the lock will lock when the input is opened regardless if the Day Night input or the SW input is closed Door monitor switch magnet serial parallel Input 12 13 If a standard electric strike with built in magnet can t be used you here have a possibility to connect an external door monitor switch When the input is closed the motor lock get a locking signal This input norm...

Page 16: ...no separate feeding has to be connected to the door only the Ethernet connection With PoE 12V locks are used See sketch below PoE switch LCU9101 Locks that can be used with PoE Abloy 8164 II 8165 II EL650 II Assa Evolution 810S 811S Assa Classic 8000S 8001S ASSA Solid 575 12 2007 and later ASSA Solid 571 12V DC ASSA Solid 514 12VDC ABLOY 580 ...

Page 17: ...ion Manual configuration Automatic configuration The easiest configuration method which is recommended is an automatic configuration In this section we show step by step how the automatic configuration is performed An automatic configuration means that the network settings are made with DHCP in other words the allocation of IP number netmask DNS server and router are made automatically fro a DHCP ...

Page 18: ...DOG LED flashes slowly when the control unit is starting up and flashes faster when the control unit is running The yellow LED marked A next to the WDOG diode flashes when the control unit is trying to get in contact with the server This can take a couple of seconds When the control unit has established contact with the server the yellow A diode is lit The automatic configuration of the control un...

Page 19: ...e computer see below Installation of drivers for USB configuration LCU9101 automatically starts a serial console on the USB port when it is connected to a computer with the correct driver installed USB works with plug and play technique Do not plug it in and out several times When you disconnect the cable you should restart your terminal software Unpack the zip file drivers LCU9101 USB located on ...

Page 20: ...Windows Teraterm free software Regardless of which terminal software you use the communication should be set to 99600 bps 8 bits no parity one stop bit and now flow control For detailed information about how the different terminal software works see the user guide for each software Configuration via the terminal software Configuration guide Setup Wizard To facilitate the configuration there is a b...

Page 21: ...p At a manual configuration have this information at hand IP address of the control unit netmask of the control unit The IP address to the default gateway IP address of the DNS address IP address or name of the ARX server 3 Test the communications with the ARX server Tests the communication between the control unit and the ARX server 4 Trace the network route to the ARX server With this option you...

Page 22: ...0 00 02 IP Address automatic via DHCP Netmask automatic via DHCP Gateway automatic via DHCP DNS Server automatic via DHCP ARX Server arx Setup Menu 1 Show current configuration and status 2 Run the setup wizard 3 Test the communications with the ARX server 4 Trace the network route to the ARX server 5 Reboot 6 Master reset 0 Quit What do you want to do _ ...

Page 23: ...p Starts the configuration guide LCU Wizard nv set arx IP adress States the IP address to the ARX Server nv set arx servernamn States another name DNS of the ARX Server the default name is arx nv set dns IP adress States the IP address for a possible DNS Server nv set domain domän States the domain the control unit belongs to ex company com nv set ip ip adress States an IP address for the control ...

Page 24: ...keyboard combination Ctrl C cancels the ping check reboot Restarts the control unit ifconfig Shows the present network settings logread Show logs route n Shows gateway settings n lead to an IP view traceroute datornamn ip adress Shows the route for the data packages tcptraceroute datornamn ip adress 5002 Shows the way a data package takes to correct port on the server only new firmware cat etc res...

Page 25: ...d restarts ACP again Tip After typing acp and the text line Command is shown type help to see a list over all available options acp clean clean deletes the database and all settings killall udhcpc udhcpc Restarts DHCP cat BUILD Prints out the firmware version installed in the control unit Fwupdate dfr arx firmware fw zip run Updates firmware via existing connection Note ARX ACCESS 1 7 and later Na...

Page 26: ...ient keys 2797 bytes client keys Key handling To guarantee a high security in the communication between the control unit LCU and ARX Server two different types of keys are used factory keys and client keys The factory keys are already stored in the control unit at delivery They are unique for each control unit When the control unit establish contact with the ARX Server and is approved the control ...

Page 27: ...temperature to avoid condensing 5 40 C Own consumption LCU9101 24V DC Max 100mA Flash memory 32 Mbyte RAM memory 32 Mbyte SDRAM Operating system Linux Ethernet 10BASE T 100BASE TX Configuration port USB B mini Card 100 000 Relay current limitation 1A 24V Total 12V load in LCU9101 in other words 12V electric strike reader and 12V regulated output Max 0 7A 700mA ...

Page 28: ...28 LCU9101 Dimensions 36 Diagram LCU9101 Reader Läsare Motor lock Motorlås Reader Läsare Electric strike Elslutbleck 7 8 9 10 1 2 13 12 1 1 2 2 3 4 3 4 C C 12V 0V RTE Öppnarknapp 14 ...