12
SE LP10 CL33600 Cylindrical Lock
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
7) Installation Instructions (Continued)
Fig. 3a
Reader
Backplate
Fire Plate
Outside Face
of Door
(2) #8 x 5/8” Phillips flat head
self-drilling screws
1. For fire-rated doors only
, install reader backplate and fire
shield to door using two (2) #8-18 x 5/8” Phillips flat head
self-drilling screws (Fig. 3a).
2. For exterior doors, install reader backplate and gasket using
two (2) #8-18 x 5/8” Phillips flat head self-drilling screws
(Fig. 3b).
3. For non-fire rated interior doors, no fire shield or gasket is
required; simply install backplate using two (2) #8-18 x 5/8”
Phillips flat head self-drilling screws.
Fig. 3b
Gasket
(for exterior doors)
Observe precautions for handling electrostatic sensitive devices.
!
!
If the SE LP10 reader is installed with a module (Fig. 4), make sure that
the reader is powered down when inserting/removing the module; i.e., do
not “hot-plug” (remove/insert while reader is powered) module as it may
damage the reader.
Fig. 4a
3. Install Reader Backplate and (Optional*) Fire Shield or Gasket:
4. Install SE LP10 Reader and Trim Bezel: