IC Core Deadbolt Installation
Figure 6
Cylinder
Tab
Deadbolt Screw
Deadbolt Front
Housing Collar
Deadbolt Assembly
#8-32
Screw
Thumbturn
Assembly
Mounting Screw
Mounting Screw
Mounting Screw
Mounting
Screw
(DL2200
Series)
Mounting Plate
Support Plate
Outside
Cylinder
Housing
Assy. - LFIC
Inside Cylinder Housing Assy. - LFIC
Outside Cylinder
Housing Assy. - SFIC
Inside Cylinder
Housing Assy. - SFIC
Before installing cylinder,
position IC driver as shown.
Turn SFIC
face plate 90
˚
to expose
mounting holes
Cylinder
Housing
Collar - LFIC
Cylinder Tailpiece
a
Install Deadbolt
a. Insert deadbolt unit into hole in door edge, making certain that tab on deadbolt is facing up as shown
in Figure 6.
b. Fasten deadbolt front and deadbolt assembly to door with two (2) deadbolt screws.
c. Extend the deadbolt by turning the slot in the hub.
Keep deadbolt extended during installation .
b
Install Outside
a. Position IC driver on cylinder housing as shown, install cylinder into cylinder housing assembly then
remove the key from cylinder. If the plastic disposable temporary core is used, turn the plastic plug so
that the slot is vertical.
b. For 11-function, 13-function, and 17-function lock installation, shorten cylinder tailpiece if necessary
by breaking it off at the score mark with pliers.
c. Insert outside cylinder housing assembly though housing collar onto door with cylinder tailpiece
going through slot in hub of deadbolt.
d. Secure outside cylinder housing assembly mounting plate and support plate to door with two (2)
1/4-20 mounting screws if applicable.