Assa Abloy Cabinet Lock Series Installation Instructions Manual Download Page 8

 
 

 

Part Number 3085006.001, Rev 3 

 

 

10.

 

 Attaching the Wiring 

 

New 4-/8-Pin Molex 

Integrated Wiegand:  K/KS200 Cabinet Locks, ElectroLynx Wire Color/Function Assignments 

Connecto

8-Pin Molex Connector 

4-Pin Molex Connector 

Pin/Wire 

Color

 

Black 

White 

N/A 

N/A 

Red 

Green 

Blue 

Yellow 

Violet 

Pink 

Gray 

Tan 

Function 

12 VDC 

Reader 

Wiegand 

Data 

N/A 

N/A 

12 VDC 

Reader 

Wiegand 

Data 

LED 

12/24 

VDC/ 

Lock 

Tamper

/ DPS 

12/24 

VDC/ 

Lock 

Tamper

/ DPS 

Setting 

NEG 

Data 1 

N/A 

N/A 

POS 

Data 0 

RED 

Green 

COM, - 

NC, + 

COM, + 

COM, - 

 

Legacy 10-Pin Molex to 4-/8-Pin Molex 

Integrated Wiegand:  K/KS200 Cabinet Locks, ElectroLynx Wire Color/Function Assignments

 

Connector 

8-Pin Molex Connector 

4-Pin Molex Connector 

Pin/Wire 

Color

 

Black 

White 

N/A 

N/A 

Red 

Green 

Orange 

Brown 

Gray 

Yellow 

Violet 

Blue 

Function 

12 VDC 

Reader 

Wiegand 

Data 

N/A 

N/A 

12 VDC 

Reader 

Wiegand 

Data 

LED 

12/24 

VDC/ 

Lock 

Tamper/ 

DPS 

12/24 

VDC/ 

Lock 

Tamper/ 

DPS 

Setting 

NEG 

Data 1 

N/A 

N/A 

POS 

Data 0 

RED 

Green 

COM, - 

NC, + 

COM, + 

COM, - 

 

a.

 

CONNECT the Lock Side Interface Cable to the lock.

 

 

b.

 

CONNECT the Lock Side Interface Cable to the optional System Side Interface Cable (see Connector and Cable Diagram). 

c.

 

RUN the System Side Interface Cable, as required. 

d.

 

ATTACH the included 4-Pin and 8-Pin Molex Female Connectors to the bare wire side of the System Side Interface Cable. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

    Locke side 
Interface Cable 

  

                  (Optional accessory) 
 CBL 6-QC12- lock side interface cable 6ft 
 CBL 12-QC12- system side interface cable 12ft 

Summary of Contents for Cabinet Lock Series

Page 1: ...cket Lock Body Drill Drill bits 5 32 1 2 Approved Credential i e iCLASS or Prox ID card Phillips drivers P0 P2 Pencil Wire Stripper Voltage 12 24 VDC 10 Power Supply not provided HES K200 622 Reader C...

Page 2: ...es of iCLASS Elite and NFC over HCE Credentials Supported 125 kHz Proximity or 13 56 MHz iCLASS iCLASS Elite iCLASS SEOS iCLASS SE ISO 15693 ICLASS ISO 14443A Mifare Mifare Plus Desfire SE Desfire EV1...

Page 3: ...tion A but it can be accessed in orientations B C and D 1 ESTABLISH the horizontal centerline of the latch a HOLD the lock body to the inside of the door and POSITION it generally where you would like...

Page 4: ...USE the Lock Reader Template NOTE The orientation will be reversed for a right hand door a CUT through line to separate the Strike Plate Template b PEEL OFF the protective layer of the Lock Template...

Page 5: ...F a Cam Lock key override will be used AND the orientation allows for installation THEN INSTALL the Key Override Paddle a INSERT the paddle s arm into the opening shown and ALIGN the rails of the padd...

Page 6: ...ew to attach the antenna reader to the outside case Table 2 8 INSTALL the lock body a REMOVE the cover from lock body b PLACE the lock on the inside of the door threading the cable through the lock c...

Page 7: ...r wire to the lock body NOTE The antenna reader wire connector is engineered to fit only one way a INSERT the antenna reader wire connector ensuring correct orientation b TUCK excess cable into the lo...

Page 8: ...ents Connector 8 Pin Molex Connector 4 Pin Molex Connector Pin Wire Color 1 Black 2 White 3 N A 4 N A 5 Red 6 Green 7 Orange 8 Brown 1 Gray 2 Yellow 3 Violet 4 Blue Function 12 VDC Reader Wiegand Data...

Page 9: ...stalling on a double door skip to Step 15 a PEEL OFF the protective layer of the Strike Plate Template and ALIGN it to both the latch centerline and the cabinet edge b DRILL the two pilot holes shown...

Page 10: ...over the holes on the bracket b INSERT and TIGHTEN the three 6 32 x 5 16 3 5 mm x 7 94 mm provided screws FCC Statement This device complies with part 15 of the FCC Rules Operation is subject to the...

Page 11: ...r toute interference y compris des interf rences qui peuvent provoquer un fonctionnement ind sirable du p riph rique Conformit aux normes IC Cet appareil est confrome avec Industrie Canada exempt de l...

Page 12: ...12 Part Number 3085006 001 Rev 3 For Technical Support please call 1 800 626 7590 For information about ASSA ABLOY Electronic Security Hardware cabinet lock solutions visit assaabloyesh com...

Reviews: