1.

 

Install the lock case. The six-sided follower shall 
be turned against the panic device. The gap 
between door and frame shall be 1-3 mm to 
insure a proper function.  
Install the strike plate. 
Make sure that the latches and the strike plate are 
well lubricated and operate smoothly.  

1.

 

 
 
 

2. Outside cylinder is fixed by four high security bolts 
through the round mounting piece.  
The two steering pins are, if necessary, cut according to 
the table below and pressed into the mounting piece. 

3. Cut the inside cylinder follower according to the table 
below. Attach the cylinder to the central unit bottom 
plate with two 13 mm screws. 

Summary of Contents for ASSA 1125

Page 1: ...363761 363762 363763 363764 363765 och 363766 Varning S kerhetsegenskaperna p denna produkt r avg rande f r dess verensst mmelse med SS EN 1125 Ingen modifiering eller ndring av n got slag annat n de...

Page 2: ...Montera slutblecket Tillse att slutbleck och l shusets fall fallar r v l smorda och l per l tt 2 Utsidans cylinder monteras med 4 st h gh llfasta cylinderskruvar genom den runda styrningen De tv styr...

Page 3: ...52 mm 4 Justera stoppbrickan p den sexkantpinnen enligt tabell med hj lp av det bifogade r rverktyget Tv l ngder av sexkantpinnar bifogas f r olika d rrtjocklekar Pinnen kapas vid behov C 5 Stoppbrick...

Page 4: ...sning via cylinder p insida och utsida Indragning av regel fall fallar via cylinder p insida och utsida 10 Koppla ihop tryckst ngens l nkarm med centralenhetens kulkoppling och montera l sringen p l...

Page 5: ...rregling av regel fall fallar Vid behov justeras l nkarmen enligt f ljande Ingen f rregling mekanismen f r mycket f rsp nd Vrid l nkarmens kulkoppling medurs Ej helt indragen fall f r kort slag p l nk...

Page 6: ...a Page 6 15 160824 15 Montera utsidans trycke t ckskylt 17 Montera bifogad efterlysande dekal p tryckst ngen 18 Funktionsprova terigen enligt punkt 11 16 Montera den fr mre k pan och tryckst ngen p ce...

Page 7: ...synlig L shus Underh llsintervall Minst tv g nger per r Sm rjning med fett p b da sidor av fall och regel skall ske vid installation samt d refter minst tv g nger per r Anv nd sm rjfett med god vidh...

Page 8: ...el 2530 50 70 with ordering numbers 363759 363760 363761 363762 363763 363764 363765 and 363766 Warning The safety features of this product are essential to its compliance with EN 1125 No modification...

Page 9: ...e plate Make sure that the latches and the strike plate are well lubricated and operate smoothly 1 2 Outside cylinder is fixed by four high security bolts through the round mounting piece The two stee...

Page 10: ...ding to the table below Put the adjusted six sided follower into the lock case with the stop washer against the cylinder follower on the lock case Two lengths of the six sided follower are enclosed in...

Page 11: ...side cylinder Retraction of latch and deadlocking through in and outside cylinder 10 Connect the ball and socket joint between the panic bar and the central unit Secure the ball and socket joint with...

Page 12: ...hes If necessary adjust the link arm like this No deadlocking mechanism to hard Turn the socket joint on the link arm clockwise Not fully retracted latch to short movement on the link arm Turn the soc...

Page 13: ...accessory handle or cover plate When handle is used se picture how spindle and spindle spring is to be installed 17 Attach enclosed after glowing stripe on the push bar 18 Test the function again acco...

Page 14: ...Lock case Regular intervals of at least Six months Lubricate both sides of latch and dead bolt at installation and there after every six month Use quality grease with high adhesive capacity such as A...

Page 15: ...ASSA AB 091189 Utg va Edition 5 Sida Page 15 15 160824...

Reviews: