background image

ASSA AB 091189  
Utgåva / Edition 5 

Sida / Page 8 / 15 

160824  

Mounting instruction panic exit device ASSA 1125

 

 
This mounting instruction is intended for installation of panic exit device ASSA 1125 with 
following ordering numbers: 361282, 361283 and 361284 in combination with ASSA lock 
cases model 761-50/70, 762-50/70, 767-50/70 and 772-50/70. 

 

With these lock cases ASSA 1125 can be installed together with following outside modular 
profile accessories:  
- Accessory set ASSA 3325, ordering no 354565, including outside round cylinder cover and 
handle. 
- Accessory set ASSA 3425, ordering no 354564, including outside round cylinder cover and 
cover plate for handle position. 
 
ASSA 1125 must be installed together with ASSA strike plate model 1264 1-8 with following 
ordering numbers: 357207, 357208, 357730, 357732, 357728, 357729, 357731   and 357733. 
Model 1487 1-5 with ordering numbers: 357545, 357546, 357547, 357547 and 357548. 
Model 2530-50/70 with ordering numbers: 363759, 363760, 363761, 363762, 363763, 
363764, 363765 and 363766. 
 

 

Warning!

 

The safety features of this product are essential to its compliance with EN 1125. 
No modification of any kind, other than those described in these instructions, are permitted. 
ASSA takes no responsibility for products not mounted as described in these instructions or if 
enclosed maintenance and operating instruction not are followed.  
 

Classification according to EN 1125:2008

 

 

 

 

 

 

 

 

 

 

 

   

10 

   

   

 

 

 

 

 

 

 

 

 

 

   

1) 

(3) suitable for use in high frequency applications; 

   

2) 

(6) tested to 100 000 cycles; 

   

3) 

(6) for a door mass of up to 200 kg, 

   

 

door width ≤1320 mm, door height ≤2520 mm; 

   

4) 

(B) suitable for use on fire/smoke resisting door assemblies; 

5) 

(1) safe for use on escape route doors; 

   

6) 

(3) high corrosion resistance; 

   

7) 

(2) grade 2 security level 1000 N; 

   

8) 

(2) horizontal bar projection of up to 100 mm; 

   

9) 

(B) "touch-bar" type B of panic exit device; 

   

10) 

(A) suitable for use on a single door and double door: active leaf only. 

Important!! 
 
Make sure that the deadlocking latch hits 
the beam on the strike before you close 
the door. 

Summary of Contents for ASSA 1125

Page 1: ...363761 363762 363763 363764 363765 och 363766 Varning S kerhetsegenskaperna p denna produkt r avg rande f r dess verensst mmelse med SS EN 1125 Ingen modifiering eller ndring av n got slag annat n de...

Page 2: ...Montera slutblecket Tillse att slutbleck och l shusets fall fallar r v l smorda och l per l tt 2 Utsidans cylinder monteras med 4 st h gh llfasta cylinderskruvar genom den runda styrningen De tv styr...

Page 3: ...52 mm 4 Justera stoppbrickan p den sexkantpinnen enligt tabell med hj lp av det bifogade r rverktyget Tv l ngder av sexkantpinnar bifogas f r olika d rrtjocklekar Pinnen kapas vid behov C 5 Stoppbrick...

Page 4: ...sning via cylinder p insida och utsida Indragning av regel fall fallar via cylinder p insida och utsida 10 Koppla ihop tryckst ngens l nkarm med centralenhetens kulkoppling och montera l sringen p l...

Page 5: ...rregling av regel fall fallar Vid behov justeras l nkarmen enligt f ljande Ingen f rregling mekanismen f r mycket f rsp nd Vrid l nkarmens kulkoppling medurs Ej helt indragen fall f r kort slag p l nk...

Page 6: ...a Page 6 15 160824 15 Montera utsidans trycke t ckskylt 17 Montera bifogad efterlysande dekal p tryckst ngen 18 Funktionsprova terigen enligt punkt 11 16 Montera den fr mre k pan och tryckst ngen p ce...

Page 7: ...synlig L shus Underh llsintervall Minst tv g nger per r Sm rjning med fett p b da sidor av fall och regel skall ske vid installation samt d refter minst tv g nger per r Anv nd sm rjfett med god vidh...

Page 8: ...el 2530 50 70 with ordering numbers 363759 363760 363761 363762 363763 363764 363765 and 363766 Warning The safety features of this product are essential to its compliance with EN 1125 No modification...

Page 9: ...e plate Make sure that the latches and the strike plate are well lubricated and operate smoothly 1 2 Outside cylinder is fixed by four high security bolts through the round mounting piece The two stee...

Page 10: ...ding to the table below Put the adjusted six sided follower into the lock case with the stop washer against the cylinder follower on the lock case Two lengths of the six sided follower are enclosed in...

Page 11: ...side cylinder Retraction of latch and deadlocking through in and outside cylinder 10 Connect the ball and socket joint between the panic bar and the central unit Secure the ball and socket joint with...

Page 12: ...hes If necessary adjust the link arm like this No deadlocking mechanism to hard Turn the socket joint on the link arm clockwise Not fully retracted latch to short movement on the link arm Turn the soc...

Page 13: ...accessory handle or cover plate When handle is used se picture how spindle and spindle spring is to be installed 17 Attach enclosed after glowing stripe on the push bar 18 Test the function again acco...

Page 14: ...Lock case Regular intervals of at least Six months Lubricate both sides of latch and dead bolt at installation and there after every six month Use quality grease with high adhesive capacity such as A...