background image

The global leader in  

door opening solutions

Aperio

®

Online

Quick 

Installation

Guide

Document No: ST-001322-B, Issue date: 11 October 2013

Summary of Contents for Aperio

Page 1: ...The global leader in door opening solutions Aperio Online Quick Installation Guide Document No ST 001322 B Issue date 11 October 2013 ...

Page 2: ...rio Programming Application 6 Information of encryption key 6 Checklist for pairing and configuration of locks sensors and communication hubs 7 Preparation before quick installation 8 Step 1 Making a new door installation 8 Step 2 Scanning for Communication hubs 9 Step 3 Pairing locks sensors with communication hub 10 Step 4 Configuring locks and communication hubs Wizard 12 Step 5 Apply saved con...

Page 3: ... 6 4 of the Aperio Online Programming Application Applicable Products This manual can be used for AH15 20 30 communication hubs For AH40 communication hub refer to the Aperio Online Programming Application Manual ref 1 Product availability The products included in this manual may not be available on all markets Please check your local ASSA ABLOY company for details Aperio support in the EAC system...

Page 4: ...adio device connected to one of its USB ports The USB radio device enables the application to connect via a Communication Hub to the door lock The lock communicates via the Communication Hub either with the EAC or with the Programming Application Read more in the Aperio Online Programming Application Manual Regulatory and security information Refer to the Programming Application manual for regulat...

Page 5: ...essary However configuration using the Aperio Pro gramming Application is still needed To perform pairing with communication hubs set in Pairing mode do the following 1 Power cycle the communication hub if necessary and check that the LED is constant yellow Yellow Pairing active 2 Hold the credential in front of the lock to activate it or engage the magnet for the sensor Result Communication hub p...

Page 6: ...on of the Programming Application and the USB Radio dongle refer to the Aperio Online Programming Application manual ref 1 Information of encryption key To obtain secure communication between communication hubs and locks sensors an Encryption key is used This Encryption Key should be handled with the same care as the Master Key in a traditional Master Key System A person with access to the Encrypt...

Page 7: ...rs Step 4 configuring locks and communication hubs setting security mode addressing mode override credentials etc Step 5 Apply saved configuration on several locks Step 6 testing after configuration For some configurations a number of additional advanced settings can be necessary such as configuration of status and alarm messages configuration of the radio communication These and a number of other...

Page 8: ...cation hub is powered 8 24V and that batteries are installed in the lock Step 1 Making a new door installation The first step is to create a new door installation which will handle all the communication hubs and Aperio locks sensors in the access control system 1 Insert the USB Radio dongle and start the Aperio Programming Application 2 Select File New in the Programming Application 3 Enter a name...

Page 9: ...scan to find communication hubs Or open an earlier created installation Result All communication hubs within reach of the USB Radio device of your computer are displayed in the scan result table 8 Locate a communication hub by the last four characters of the communication hub MAC address ex 01CF in the scan result table The same characters should be on a label on the cover of the communication hub...

Page 10: ...ude in your installation Click Show details to view detailed information in the installation view Step 3 Pairing locks sensors with communication hub AH30 AH40 version of the communication hub can be paired with a combination of up to 8 locks sensors AH15 AH20 can manage one lock sensor 1 Right click and select Communication hub Pair with lock or sensor ...

Page 11: ... the credential at the lock or engage the magnet for the sensor to pair the hardware with the communication hub 3 When the lock has stopped blinking you can click Done to see the pairing result Result The result is displayed 4 Repeat this pairing process for all communication hubs and locks sensors within reach of the USB Radio Dongle ...

Page 12: ...Aperio Online Programming Application manual ref 1 Before configuration check that Update device time during door configuration is activated Enter the Settings Installation Settings window Follow the steps below to perform a default configuration of locks sensors and communication hubs The changes you make during the update of the door configuration are not carried out until you perform the device...

Page 13: ...ngs are necessary 3 If advanced mode is activated the Keypad configuration page will appear Leave without changes by clicking Next 4 On the Override Credential page it is recommended to add a credential Select the credential type in the drop down list and click Add and enter credential information in this case MIFARE Classic UID This credential can for example be used to gain access through all do...

Page 14: ...ormed correctly by setting all locks in customer mode the radio communication will not be secure and the locks will therefore be vulnerable to intrusion attempts 7 To enable secure communication using the encryption key select Switch to customer mode in device click OK and then Next in the wizard main window 8 On the Electronic Access Controller Setting page in the Enable EAC Address via Dip Switc...

Page 15: ...eck that the summary of the configuration tasks that will be sent to the lock is correct 12 Click Save configuration to facilitate further lock configurations for other hubs locks using the same communication hub Enter a configuration name and click OK 13 Click Next in the wizard main window to download the configuration to the lock ...

Page 16: ...tial in front of the lock to activate the radio 15 After successful update click Close Using the wizard for a communication hub with only one lock paired customer mode is set both for the lock and communication hub For communication hubs with several locks paired a message stating that there is a security mode conflict will appear ...

Page 17: ...f you have more than one lock that will use the same configuration you can apply the recently saved configuration on any lock in your installation 1 Right click on a lock and select Lock sensor Apply configuration your configuration 2 Confirm the update by clicking Confirm 3 Hold the credential in front of the lock sensor to download the configuration ...

Page 18: ...e 11 oktober 2013 Aperio Online 18 4 After successful update click Close 5 Repeat the configuration for all locks paired to the communication hub 6 Finally activate customer mode for the communication on the right click menu Communication hub Switch to customer mode ...

Page 19: ...connected to EAC This indicates that the installation and configuration have been performed correctly Green Online 2 Hold a credential that is invalid in the EAC system in front of the lock Result Access is denied and the lock LED flashes red once One red flash 1 second Access denied EAC online 3 Hold a credential that is valid in the EAC system in front of the lock Result Access is granted and th...

Page 20: ...Green three red flashes Aperio lock and EAC offline Yellow off fast flash UHF communication Some special LED indication schemes are used during lock maintenance actions Yellow green Pairing active 2 sec Ethernet LED indication The LED on the AH40 communication hub indicates both the status of the Ethernet link level and ethernet communication 2 sec Green Green off fast flash Ethernet link connecte...

Page 21: ...Three red flashes 5 second each Lock mechanism is blocked when closing Tamper Ten red flashes 125 sec each repeated every 10 sec Time to replace the battery Error in lock maintenance required Ten red flashes 125 sec each Repeated every 10 sec if lock can t close 2 1 Battery reached end of life lock disabled Card access configurable Card PIN access configurable EAC response time Enter PIN One yello...

Page 22: ... if red Code in event log 2 Main board firmware corrupt 0x0001 3 Override list corrupt 0x0002 4 Production data corrupt 0x0004 5 Security data corrupt 0x0008 6 Configuration data corrupt 0x0010 7 Load Circuit Error 0x0020 8 Configuration data corrupt 2 0x0040 9 Secure Area Encryption Key error 0x0080 10 Secure Area Motor error 0x0100 11 Secure area communication error 0x0200 12 Secure area memory ...

Page 23: ... for the installation in the communication hub field and in the Lock sensor field of the scan result table The communication hub and or communication hub paired with a lock sensor belongs to another installation and has another encryption key The lock sensor is not paired with the communication hub 1 Switch installation or create a new installation with the correct encryption key 2 Pair the lock s...

Page 24: ...unication hub The lock sensor and communication hub are not paired The lock sensor and the communication hub have different channel masks The battery of the lock sensor has run out The status message intervals differ between the hub and the lock Repeat the scanning process by selecting Scan Scan all Pair the lock sensor and communication hub in the Configure door wizard of the Programming Applicat...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ...ASSA ABLOY is the global leader in door opening solutions dedicated to satisfying end user needs for security safety and convenience Wireless lock technology Contact www assaabloy com aperio ...