background image

11

Physical Dimensions 82 mm x 82 mm x 37 mm (H x W x T)

Power Supply

8-24 VDC or Power over Ethernet (PoE)

Power Rating

The power supply shall be able to deliver minimum

1.2 W and be 3 A over current protected. Wire 

requirements 16-22 AWG. 

PoE

IEEE 802.3.af compliant

 class 1 Powered device (PD)

Ethernet

10BASE-T / 100BASE-TX Local Area Network

Radio Standard

IEEE 802.15.4 (2400 – 2483,5 MHz) 

16 channels (11-26) 

AES 128 bit encryption

Receiver Sensitivity

-100 dBm 

Wireless Transmit 

Power

10 dBm/MHz. Peak value from average detector 

according to EN ETSI 300 328 Maximum spectral 

density.

Wireless Operating 

Range 

Indoors up to 25 m depending upon installed

environment.

Internal Antenna

Two port cross polarized patch antenna.

External Antenna

One reverse polarity SMA external antenna 

connector. AH40 is certified to be used with ASSA 

ABLOY external antenna AH ANTENNA 1. If other 

external antenna is used it must be of same type 

(dipole) and not have larger antenna gain than 

3.6 dBi.

Operating 

Temperature

5 °C to 35 °C

Humidity

< 95 % non-condensing

IP Classification

IP20

Safety, Radio and 

EMC

IEC 62368-1:2014

EN 62368-1:2014 + A11:2017

UL/CSA 62368-1:2014

EN 301 489-1 V2.1.1

EN 301 489-17 V3.2.0

EN 300 328 V2.2.2

EN 50130-4:2011 + A1:2014

EN 62311

FCC 47CFR Part 15 subpart B and subpart C

ISED RSS-247 and ICES-003

AS/NZS 4268

AH40 - Technical Data 

Summary of Contents for Aperio AH40

Page 1: ...1 Aperio AH40 Hub Installation Guide Experience a safer and more open world ...

Page 2: ...L CSA 62368 1 AH40 FCC and ISED Canada Statements 3 AH40 Placement of Communication Hub 5 AH40 Mounting Americas Adapter Plate 6 AH40 Mounting Bottom Cover 7 AH40 Connectors 8 AH40 Jumpers 9 AH40 Communication Hub LED Indications 10 AH40 Technical Data 11 ...

Page 3: ...nt does cause harmful interference to radio or television recep tion which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which...

Page 4: ...dmissible maximal Les types d antenne non inclus dans cette liste et dont le gain est supérieur au gain maximal indiqué pour tout type figurant sur la liste sont strictement interdits pour l exploitation de l émetteur Type d antenne Gain d antenne maxima dBi Impédance ohm Antenne interne 3 6 50 AH ANTENNA 1 2 15 50 L émetteur récepteur exempt de licence contenu dans le présent appareil est conform...

Page 5: ... with 8 locks AH40 can manage up to 64 locks Note AH40 must be installed into a junction box ex European 2 Gang Aperio bottom cover or with Americas adapter plate to junction box AH40 must be installed by qualified and trained personal Indoor installation only 25 m 80 ft ...

Page 6: ...6 AH40 Mounting Americas Adapter Plate US version 1 3 4 5 2 AH40 Mounting Americas Adapter Plate Americas Adapter Plate Top Cover External Antenna Option Screw 4 x 35 mm Screw 3 x 10 mm ...

Page 7: ...7 1 3 2 AH40 Mounting Bottom Cover Bottom Cover Top Cover External Antenna Option Screw 4 x 35 mm Screw 3 x 10 mm AH40 Mounting Bottom Cover EU version ...

Page 8: ...nnector Connection to the Electronic Access Control system through a 10BASE T 100BASE TX Local Area Network Can also be used for power supply if connected to a IEEE 802 3 af compliant Power Sourcing Device PSE Wire requirements CAT5 or higher J800 Power supply input 8 24 VDC 1 2 W The power supply shall be 3 A over current protected Wire requirements 16 22 AWG PAIR J700 8 24V J800 EXT J200 J400 IN...

Page 9: ...e by connecting the two right pins Note If the pairing jumper if removed within 10 seconds from from boot up and the Hub LED is lit all paired devices will be unpaired AH40 Jumpers Note To install an external antenna use a thin screwdriver and gently bend the antenna cap loose Be careful there are sensitive components behind the cap PAIR J700 8 24V J800 EXT J200 J400 INT S100 ...

Page 10: ...amming Application and an USB radio dongle further system installation parameters can be set The LINK LED on the Ethernet connector indicates both status of the Ethernet Link level and if communication is ongoing Green Online Green One Red Flash Aperio Lock Offline Green Two Red Flashes EAC Offline Green Three Red Flashes Aperio Lock and EAC Offline Yellow Off Fast Flash UHF Communication Yellow P...

Page 11: ...tral density Wireless Operating Range Indoors up to 25 m depending upon installed environment Internal Antenna Two port cross polarized patch antenna External Antenna One reverse polarity SMA external antenna connector AH40 is certified to be used with ASSA ABLOY external antenna AH ANTENNA 1 If other external antenna is used it must be of same type dipole and not have larger antenna gain than 3 6...

Page 12: ...12 www assaabloy com aperio D001042372 1 Experience a safer and more open world ...

Reviews: