Auxiliary Panel Header
(18-pin AUX_PANEL1)
(No. 13)

G

N

D

B

M

C

_S

M

B

C

LK

1

B

M

C

_A

le

rt

1_

N

C

A

S

E

O

P

E

N

#

1

S

M

B

_S

M

B

D

A

T

A

1

+3

V

S

B

LA

N

1_

LI

N

K

LE

D

_P

W

R

LA

N

2_

LI

N

K

LE

D

_P

W

R

+5

V

S

B

G

N

D

G

N

D

LO

C

AT

O

R

LE

D

+

LO

C

AT

O

R

LE

D

-

LO

C

AT

O

R

B

T

N

#

S

ys

te

m

_F

au

lt_

LE

D

_N

S

ys

te

m

_F

au

lt_

LE

D

_P

A

B

C

D

E

This header supports multiple 
functions on the front panel, 
including front panel SMB, 
internet status indicator.

Front and Rear 
Fan Connectors
(4-pin FRNT_FAN1)
(No. 4)
(4-pin FRNT_FAN2)
(No. 20)
(4-pin REAR_FAN1)
No. 28)

FAN_SPEED

FAN_SPEED_CONTROL

FAN_VOLTAGE

GND

4     3     2    1

Please connect the fan cables to 
the fan connectors and match 
the black wire to the ground 
pin. All fans supports Fan 
Control.

A. Front panel SMBus connecting pin (6-1 pin FPSMB)  
This header allows you to connect SMBus (System Management Bus) equipment.  It can 
be used for communication between peripheral equipment in the system, which has slower 
transmission rates, and power management equipment.  
 
B. Internet status indicator (2-pin LAN1_LED, LAN2_LED)  
These two 2-pin headers allow you to use the Gigabit internet indicator cable to connect 
to the LAN status indicator. When this indicator flickers, it means that the internet is prop-
erly connected. 
 
C. Chassis intrusion pin (2-pin CHASSIS)  
This header is provided for host computer chassis with chassis intrusion detection designs. 
In addition, it must also work with external detection equipment, such as a chassis intru-
sion detection sensor or a microswitch. When this function is activated, if any chassis 
component movement occurs, the sensor will immediately detect it and send a signal to this 
header, and the system will then record this chassis intrusion event. The default setting is 
set to the CASEOPEN and GND pin; this function is off. 
 
D. Locator LED (4-pin LOCATOR) 
This header is for the locator switch and LED on the front panel. 
 
E. System Fault LED (2-pin LOCATOR) 
This header is for the Fault LED on the system.

Summary of Contents for D1520D4I

Page 1: ...D1520D4I D1540D4I D1540D4I 2L2T User Manual Version 1 0 Published August 2015 Copyright 2015 ASRock Rack INC All rights reserved...

Page 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agen...

Page 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Page 4: ...re installation Precautions 16 2 3 Installation of Memory Modules DIMM 17 2 4 Expansion Slots PCI Express Slots 19 2 5 Jumper Setup 20 2 6 Onboard Headers and Connectors 21 2 7 Unit Identification pur...

Page 5: ...M A R T Settings 45 3 3 8 3rd Storage Configuration 46 3 3 9 H W Monitor 47 3 3 10 WHEA Configuration 49 3 3 11 Instant Flash 51 3 5 IntelRCSetup 52 3 5 1 Processor Configuration 53 3 5 2 Advanced Pow...

Page 6: ...4 2 1 Running The Support CD 71 4 2 2 Drivers Menu 71 4 2 3 Utilities Menu 71 4 2 4 Contact Information 71 Chapter 5 Troubleshooting 72 5 1 Troubleshooting Procedures 72 5 2 Technical Support Procedur...

Page 7: ...rd Mini ITX Form Factor 6 7 in x 6 7 in 17 02 cm x 17 02 cm Support CD User Manual 2 x Serial ATA SATA 3 Cables 60cm 1 x Mini SAS Cable 6G 60cm 1 x I O Shield 1 x Screw for M 2 Socket If any items are...

Page 8: ...n ECC UDIMM 1600 1866 2133MHz ECC UDIMM 1600 1866 2133MHz RDIMM 1600 1866 2133MHz Voltage 1 2V Expansion Slot PCIe 3 0 x 16 1 slot Storage SATA Controller D1540 D1520 6 x SATA3 6Gb s 4 port from mini...

Page 9: ...ntrusion location button LED front LAN LED system fault LED TPM Header 1 IPMB Header 1 COM Header 1 Fan Header 4 1CPU 2Front 1Rear ATX Power 1 x 24 pin 1 x 8 pin System BIOS BIOS Type 128Mb AMI UEFI L...

Page 10: ...erature 10 C 35 C Non operation temperature 40 C 70 C For detailed product information please visit our website http www asrockrack com This motherboard supports Wake from on Board LAN To use this fun...

Page 11: ...utility you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash...

Page 12: ...L1 1 SATA_4 CH1_B1 64 bit 288 pin module Blue DDR4 CH1_B2 64 bit 288 pin module White DDR4 6 ATX12V1 1 PSU_SMB1 7 CPU_FAN1 HDD_PWR1 8 BAT1 1 1 LED_LAN3_4 1 1 1 1 USB_1 1 SATA_5 1 SATA_SGPIO1 FRNT_FAN2...

Page 13: ...PANEL1 1 SATA_4 CH1_B1 64 bit 288 pin module Blue DDR4 CH1_B2 64 bit 288 pin module White DDR4 6 ATX12V1 1 PSU_SMB1 7 CPU_FAN1 HDD_PWR1 8 BAT1 1 1 LED_LAN3_4 1 1 1 1 USB_1 1 SATA_5 1 SATA_SGPIO1 FRNT...

Page 14: ...TA_4 CH1_B1 64 bit 288 pin module Blue DDR4 CH1_B2 64 bit 288 pin module White DDR4 6 ATX12V1 1 PSU_SMB1 7 CPU_FAN1 HDD_PWR1 8 BAT1 1 1 LED_LAN3_4 1 1 1 1 USB_1 1 SATA_5 1 SATA_SGPIO1 FRNT_FAN2 COM1 1...

Page 15: ...DOM Power Jumper SATAPWR1 15 SATA3 Connector SATA_4 16 SATA SGPIO Connector SATA_SGPIO1 17 SATA3 Connector SATA_5 18 Speaker Header SPEAKER1 19 System Panel Header PANEL1 20 Front Fan Connector FRNT_F...

Page 16: ...CH1_B1 64 bit 288 pin module Blue DDR4 CH1_B2 64 bit 288 pin module White DDR4 ATX12V1 1 PSU_SMB1 CPU_FAN1 HDD_PWR1 BAT1 1 1 LED_LAN3_4 1 1 1 1 USB_1 1 SATA_5 1 SATA_SGPIO1 FRNT_FAN2 COM1 1 1 1 1 SPE...

Page 17: ...D15X0D4I Series 11 English No Status Description 1 Amber Front_FAN1 failed 2 Amber CPU_FAN1 failed 3 Amber Front_FAN2 failed 4 Green STB PWR ready 5 Green BMC heartbeat LED 6 Amber Rear_FAN1 failed...

Page 18: ...B 3 0 Ports USB3_12 6 10G LAN RJ 45 Port LAN4 3 UID Switch LED UID_SW_LED1 7 10G LAN RJ 45 Port LAN3 4 LAN RJ 45 Port LAN2 8 VGA Port VGA1 D1540D4I D1520D4I 2 5 3 4 1 6 No Description No Description 1...

Page 19: ...LEDs on each LAN port Please refer to the table below for the LAN port LED indications LAN Port LAN3 LAN4 LED Indications 1G For D1540D4I 2L2T Speed LED Activity Link LED Status Description Status Des...

Page 20: ...3 6G USB 2 0 USB 3 0 USB 3 0 Rear IO 2 port Front Header 2 port PCIe slot7 SIO NCT5573 BMC AST2400 Realtek 8211E PCIe x1 RGMII VGA LPC TPM Header UART COM port Header TACH PWM System FAN Header CPU x1...

Page 21: ...B 3 0 USB 3 0 Rear IO 2 port Front Header 2 port PCIe slot7 SIO NCT5573 BMC AST2400 Realtek 8211E PCIe x1 RGMII VGA LPC TPM Header UART COM port Header TACH PWM System FAN Header CPU x1 Front x4 Rear...

Page 22: ...member to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold components by the edges and do not touch the ICs 4 Whenever you uninstall any component...

Page 23: ...using this configuration 1 For dual channel configuration you always need to install identical the same brand speed size and chip type DDR4 DIMM pairs 2 It is not allowed to install a DDR DDR2 or DDR...

Page 24: ...18 English 1 2 3...

Page 25: ...cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the system unit cover if your m...

Page 26: ...s placed on these 2 pins ME Recovery Jumper 3 pin ME_RECOVERY1 No 27 Normal Mode Default ME Recovery Mode SATA DOM Power Jumper 3 pin SATAPWR1 No 14 SATA DOM SATA_4 requires 5V power supply Normal SAT...

Page 27: ...interface allows up to 6 0 Gb s data transfer rate Serial ATA3 DOM Connector SATA_4 No 15 The SATA3 DOM connector supports both a SATA DOM Disk On Module and a SATA data cable for internal storage dev...

Page 28: ...form Module TPM system which can securely store keys digital certificates passwords and data A TPM system also helps enhance network security protects digital identities and ensures platform integrity...

Page 29: ...fails to perform a normal restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in...

Page 30: ...which has slower transmission rates and power management equipment B Internet status indicator 2 pin LAN1_LED LAN2_LED These two 2 pin headers allow you to use the Gigabit internet indicator cable to...

Page 31: ...board please connect it to Pin 1 3 For more details please refer to the Cooler QVL list on the ASRock Rack website ATX Power Connector 24 pin ATXPWR1 No 3 Please connect an ATX power supply to this co...

Page 32: ...evice to this header BMC SMB Headers 5 pin BMC_SMB_1 No 23 BMC_SMB_PRESENT_1_N Power BMC_SMBCLK GND BMC_SMBDATA This header is used for the SM BUS devices LAN LED Connector LED_LAN3_4 No 9 LAN3_ACT_N...

Page 33: ...D15X0D4I Series 27 English Serial Port Header 9 pin COM1 No 22 CCTS 1 RRTS 1 DDSR 1 DDTR 1 RRXD1 GND TTXD1 DDCD 1 1 RRI 1 This COM header supports a serial port module...

Page 34: ...ront rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 8 Driver Installation Guide To install the drivers to your system please insert the support CD...

Page 35: ...apter handles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control i...

Page 36: ...CIe and mSATA This M 2_SSD NGFF Socket 3 can accommodate a M 2 PCI Express module up to Gen3 x4 32 Gb s only Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw 1 2 N...

Page 37: ...d Hand tighten the standoff into the desired nut location on the motherboard NUT2 NUT1 NUT2 Step 5 Align and gently insert the M 2 NGFF SSD module into the M 2 slot Please be aware that the M 2 NGFF S...

Page 38: ...selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features H W Monitor To display current hardware status IntelRCSetup For Intel CPU and...

Page 39: ...for the selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of...

Page 40: ...2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system t...

Page 41: ...reen In this section you may set the configurations for the following items ACPI Configura tion Configure Super IO Settings Serial Port Console Redirection CSM Parameters USB Configuration System Conf...

Page 42: ...isable PCIE devices to turn on the system from the power soft off mode Ring In Power On Use this item to enable or disable Ring In signals to turn on the system from the power soft off mode RTC Alarm...

Page 43: ...s Serial Port Use this item to enable or disable the onboard serial port Serial Port Address Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set param...

Page 44: ...ur computer and the host computer to which you are connected exchange information Terminal Type Use this item to select the preferred terminal emulation type for out of band management It is recommend...

Page 45: ...ons include None and Hardware RTS CTS VT UTF8 Combo Key Support Use this item to enable or disable the VT UTF8 Combo Key Support for ANSI VT100 terminals Recorder Mode Use this item to enable or disab...

Page 46: ...elect the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 that supports color and fun...

Page 47: ...Ms priority Launch Storage OpROM Policy Select UEFI only to run those that support UEFI option ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not...

Page 48: ...ptions Enabled Disabled Auto and Smart Auto If Auto is selected all USB ports work as USB3 0 after boot to OS If Smart Auto is selected all USB ports work as USB3 0 after boot to OS and work as USB2 0...

Page 49: ...to enable or disable the Onboard LAN1 features Onboard LAN2 This allows you to enable or disable the Onboard LAN2 features Onboard LAN3 LAN4 For D1540D4I 2L2T only This allows you to enable or disable...

Page 50: ...elected the AC power resumes and the system starts to boot up when the power recovers If Last State is selected it will recover to the state before AC power loss SR IOV Support If system has SR IOV ca...

Page 51: ...45 English 3 3 7 Hard Disk S M A R T Settings Hard Disk S M A R T Use this item to enable or disable the S M A R T Self Monitoring Analysis and Reporting Technology feature Configuration options Disab...

Page 52: ...46 English 3 3 8 3rd Storage Configuration In this section you may set the configurations or see the information of the connected 3rd storage device...

Page 53: ...e CPU fan1 s speed The default value is Smart Fan REAR_FAN1 This allows you to set the rear fan 1 s speed The default value is Smart Fan FRNT_FAN1 This allows you to set the front fan 1 s speed The de...

Page 54: ...art Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This allows you to set temperature for each stage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer The default value...

Page 55: ...u can configure Memory Error and PCIE Error log features Memory Error Memory enabling and logging setup option Correctable Error Threshold Correctable Error Threshold 1 32767 used for sparing tagging...

Page 56: ...50 English Fatal Error Enable Use this item to enable or disable PCIe Ftal errors...

Page 57: ...floppy disk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted th...

Page 58: ...up In this section you may set the configurations for the following items Processor Configu ration Advanced Power Management Configuration Memory Configuration IIO Con figuration PCH Configuration and...

Page 59: ...hreads to run on each core so that the overall performance on threaded software is improved VT d Intel Virtualization Technology for Directed I O helps your virtual machine monitor better utilize hard...

Page 60: ...rating systems and applications in independent partitions so that one computer system can function as multiple virtual systems Enable SMX Use this item to enable Safer Mode Extensions Hardware Prefetc...

Page 61: ...be hidden if the current CPU does not support Intel R SpeedStep technology Intel Turbo Boost Technology Use this item to enable or disable Intel Turbo Boost Technology Turbo Boost allows processor cor...

Page 62: ...56 English CPU C6 State Support Enable C6 deep sleep state for lower power consumption CPU Thermal Throttling Enable CPU internal thermal control mechanisms to keep the CPU from overheating...

Page 63: ...etect the memory module s inserted and assign the appropriate frequency automatically ECC Support Use this item to enable or disable DDR ECC Support Memory Information Displays memory topology with DI...

Page 64: ...h This allows you to select PCIE7 Link Width The default value is x16 PCIE7 Link Speed This allows you to select PCIE7 Link Speed The default value is Auto PCI E ASPM Support This option enables or di...

Page 65: ...TA Controller Use this item to enable or disable SATA Controller SATA Mode Selection Identify the SATA port is connected to Solid State Drive or Hard Disk Drive SATA Aggressive Link Power Mgmt Use thi...

Page 66: ...p Device If enabled for any of ports Staggered Spin Up will be performed and only the drives which have this option enabled will spin up at boot Otherwise all drives spin up at boot SATA Device Type I...

Page 67: ...D15X0D4I Series 61 English 3 5 6 Server ME Configuration Spread Spectrum Use this item to select spread specturm mode...

Page 68: ...6 Server Mgmt Wait For BMC Wait For BMC response for specified time out In PILOTII BMC starts at the same time when BIOS starts during AC power ON It takes around 30 seconds to initialize Host to BMC...

Page 69: ...ll features of System Event Logging during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use th...

Page 70: ...dress toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters statically or dynamically by BI...

Page 71: ...ssword admin For more instructions on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at h...

Page 72: ...et or change the password for the administrator account Only the administrator has authority to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password User...

Page 73: ...order Boot Option 2 Use this item to set the system boot order Boot Option 3 Use this item to set the system boot order USB Device BBS Priorities Use this item to set the system boot order from USB d...

Page 74: ...em boots up Please note that a buzzer is needed Full Screen Logo Use this item to enable or disable OEM Logo The default value is Enabled AddOn ROM Display Use this option to adjust AddOn ROM Display...

Page 75: ...D15X0D4I Series 69 English 3 9 Event Logs Change Smbios Event Log Settings This allows you to configure the Smbios Event Log Settings View Smbois Event Log This allows you to view the Smbios Event Log...

Page 76: ...ard Changes and Exit When you select this option the following message Discard changes and exit setup will pop out Select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes...

Page 77: ...The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear automatically locate and double click on the file ASRSetup exe from the root folder...

Page 78: ...3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1 Try replugging the...

Page 79: ...if the battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords rel...

Page 80: ...f your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authorization RMA...

Page 81: ...it is required to install Net Framework Please follow the steps below to enable Net Framework feature on Microsoft Windows Server 2008 R2 6 1 Installing Net Framework 3 5 1 For Server 2008 R2 1 Doubl...

Page 82: ...76 English 3 Check the box next to Net Framework 3 5 1 and then click Next 4 Click Next to continue...

Page 83: ...D15X0D4I Series 77 English 5 Click Install to start installing Net Framework 3 5 1 6 After the installation completes click Close...

Reviews: