background image

C422 WSI/IPMI

X299 WSI/IPMI

User Manual

Version 1.0

Published August 2018

Copyright©2018 ASRock Rack INC. All rights reserved.

Summary of Contents for C422 WSI/IPMI

Page 1: ...C422 WSI IPMI X299 WSI IPMI User Manual Version 1 0 Published August 2018 Copyright 2018 ASRock Rack INC All rights reserved...

Page 2: ...implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agent...

Page 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Page 4: ...les 13 2 2 Pre installation Precautions 13 2 3 Installation of Memory Modules SODIMM 18 2 4 Expansion Slot PCI Express Slot 20 2 5 Jumper Setup 21 2 6 Onboard Headers and Connectors 22 2 7 Driver Inst...

Page 5: ...ort Console Redirection 58 3 4 7 H W Monitor 61 3 4 8 Intel ME Information 63 3 4 9 ACPI Configuration 64 3 4 10 USB Configuration 65 3 4 11 Instant Flash 66 3 5 Security 67 3 6 Boot Screen 68 3 7 Ser...

Page 6: ...rivers Menu 78 4 2 3 Utilities Menu 78 4 2 4 Contact Information 78 Chapter 5 Troubleshooting 79 5 1 Troubleshooting Procedures 79 5 2 Technical Support Procedures 81 5 3 Returning Merchandise for Ser...

Page 7: ...I IPMI Motherboard Mini ITX Form Factor 6 7 in x 6 7 in 17 02 cm x17 02 cm Support CD Quick Installation Guide 1 x SATA3 Cable 60cm 1 x I O Shield 1 x Screw for M 2 Socket If any items are missing or...

Page 8: ...DIMM slots Supports up to 64GB ECC SO DIMM DIMM Sizes and Type per DIMM Quad Channel DDR4 memory technology C422 WSI IPMI SO RDIMM 8GB 4GB ECC SO DIMM 8GB 4GB Non ECC SO UDIMM 16GB 8GB 4GB X299 WSI IP...

Page 9: ...Rear Panel I O VGA Port 1 x D Sub USB 3 0 Port 2 LAN Port RJ45 2 1 IPMI LAN Ports with LED ACT LINK LED and SPEED LED Internal Connector Auxiliary Panel Header 1 include chassis intrusion location but...

Page 10: ...dows Windows 10 64 bit C422 WSI IPMI Microsoft Windows Windows 10 64 bit Linux RedHat Enterprise Linux Server 6 9 64 bit 7 3 64 bit 7 5 64 bit SUSE Enterprise Linux Server 11 SP4 64 bit 12 SP2 64 bit...

Page 11: ...all the drivers only it will pass the WHQL tests 1 3 Unique Features ASRock Rack Instant Flash is a BIOS flash utility embedded in Flash ROM This con venient BIOS update tool allows you to update syst...

Page 12: ...bit 260 pin module DDR4_C1 64 bit 260 pin module VGA1 3 IPMI LAN USB 3 0 T USB2 B USB1 LAN1 LAN2 PCIE4 SATA_0 SATA_1 SATA_2 SATA_3 FRNT_FAN2 FRNT_FAN1 OCU1 AUX_PANEL1 1 1 USB3_3_4 HDLED RESET PLED PW...

Page 13: ...C422 WSI IPMI X299 WSI IPMI 7 English Rear View M2_2 NUT110_2 25...

Page 14: ...MM Slots DDR4_A1 DDR4_B1 10 Front Fan Connector FRNT_FAN2 11 Front Fan Connector FRNT_FAN1 12 2 x 260 pin DDR4 SO DIMM Slots DDR4_C1 DDR4_D1 13 OCuLink x4 Connector OCU1 14 USB 3 0 Header USB3_3_4 15...

Page 15: ...English 1 5 Onboard LED Indicators 1 ATXPWR1 C422 WSI 1 2 3 4 1 1 No Item Status Description 1 CPU_FAN_LED1 Amber CPU_FAN1 failed 2 FFAN_LED2 Amber FRNT_FAN2 failed 3 FFAN_LED1 Amber FRNT_FAN1 failed...

Page 16: ...Indications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications Dedicated IPMI LAN Port LED Indications Activity Link LED Speed LED Status Descripti...

Page 17: ...le below for the LAN port LED indications LAN Port LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 10M bps connection or no link Blinking Yellow Data...

Page 18: ...12 English 1 7 Block Diagram...

Page 19: ...lectricity NEVER place your motherboard directly on the carpet or the like Also remember to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold compon...

Page 20: ...heck if the PnP cap is on the socket if the CPU surface is unclean or if there are any bent pins in the socket Do not force to insert the CPU into the socket if above situation is found Otherwise the...

Page 21: ...C422 WSI IPMI X299 WSI IPMI 15 English B A 4 5 6...

Page 22: ...16 English Please save and replace the cover if the processor is removed The cover must be placed if you wish to return the motherboard for after service A B A B 7 8 9 B C A...

Page 23: ...C422 WSI IPMI X299 WSI IPMI 17 English 2 2 Installing the CPU Fan and Heatsink C P U _ F A N 10 11 12...

Page 24: ...ation you always need to install identical the same brand speed size and chip type DDR4 SO DIMM pairs 2 It is unable to activate Dual Channel Memory Technology with only one or three memory module ins...

Page 25: ...C422 WSI IPMI X299 WSI IPMI 19 English 1 2 3...

Page 26: ...witched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the sys...

Page 27: ...cap is placed on the pins the jumper is Short If no jumper cap is placed on the pins the jumper is Open The illustration shows a 3 pin jumper whose pin1 and pin2 are Short when a jumper cap is placed...

Page 28: ...restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep state or powered...

Page 29: ...ipment B Internet status indicator 2 pin LAN1_LED LAN2_LED These two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status indicator When this indicator flic...

Page 30: ...7 GND FAN_VOLTAGE CPU_FAN_SPEED FAN_SPEED_CONTROL 1 2 3 4 This motherboard provides one 4 Pin CPU fan Quiet Fan connectors If you plan to connect a 3 Pin CPU fan please connect it to Pin 1 3 For more...

Page 31: ...M Header 17 pin TPMS1 see p 6 No 24 GND GND 3VSB LAD0 3V LAD3 PCIRST FRAME PCICLK 1 GND SMB_CLK_MAIN SMB_DATA_MAIN LAD2 LAD1 GND S_PWRDWN SERIRQ This connector supports Trusted Platform Module TPM sys...

Page 32: ...nagement cards that provide management features using the IPMB OCuLink Connector OCU1 see p 6 No 13 OCU1 Please connect a PCIE SSD to this connector Chassis Speaker Header 4 pin SPEAKER1 see p 6 No 16...

Page 33: ...REMMOD VROCISSDMOD Standard SKU features RAID 5 RAID 5 Write Hole Closure Only Intel SSDs are supported For further details on VROC please refer to the official information released by Intel 2 7 Drive...

Page 34: ...ndles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control is automa...

Page 35: ...M 2 PCI Express module up to Gen3 x4 32 Gb s Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw A A 20o Step 2 Gently insert the M 2 NGFF SSD module into the M 2 sl...

Page 36: ...em Description Main To set up the system time date information OC Tweaker for X299 WSI IPMI only For overclocking configurations Advanced To set up the advanced UEFI features Security To set up the se...

Page 37: ...option for the selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bot...

Page 38: ...l appear and display the system overview The Main screen provides system overview information and allows you to set the system time and date All screenshots in this document are provided for reference...

Page 39: ...U and motherboard It should be done at your own risk and expense Please use better CPU cooler for system stabil ity Red color option may cause system to be unstable which depends on CPU qual ity and s...

Page 40: ...locking ratio for the CPU Mesh which is in OC Mailbox CPU Mesh Max Ratio The sets the maximum ratio for the CPU Mesh CPU Mesh Min Ratio The sets the minimum ratio for the CPU Mesh Flex Ratio Use this...

Page 41: ...hange rate of the output voltage Higher values will result in a shorter signal rising time CPU2 SRC1 Slew Rate Adjust the BCLK signal by defining the maximum change rate of the output voltage Higher v...

Page 42: ...utput Divider The default is set to 2 where the max BCLK is 1000 MHz while divider 4 lowers the max BCLK to 500 MHz while divider 10 lowers the max BCLK to 200 MHz and divider 1 turns it into 2000 NHz...

Page 43: ...urbo Boost Max Technology 3 0 feature contain at least one processor core whose maximum turbo frequency is higher than the others Adjust Pll Adjust the Pll for higher BCLK ratio combination Pll Trim C...

Page 44: ...ration Power Limit is exceeded Short Duration Power Limit Configure Package Power Limit 2 in watts When the limit is exceeded the CPU ratio will be lowered immediately A lower limit can protect the CP...

Page 45: ...RAS Active Time tRAS The number of clock cycles required between a bank active command and issuing the precharge command Command Rate CR The delay between when a memory chip is selected and when the...

Page 46: ...clocks that are inserted between a read command to a row pre charge command to the same rank Four Activate Window tFAW The time window in which four activates are allowed the same rank CAS Write Late...

Page 47: ...Configure Read to Read different rank dead cycle Back to back READ to WRITE from different DIMM separation parameter tRRDD Configure Read to Read different DIMM dead cycle Back to back READ to WRITE...

Page 48: ...om different subranks within the same logical rank separation parameter for LRDIMM tWWDS_L Configure Back to back WRITE to WRITE from different subranks within the same logical rank separation paramet...

Page 49: ...RTL C2 Configure round trip latency RTL D1 Configure round trip latency RTL D2 Configure round trip latency IO L A1 Configure IO latency IO L A2 Configure IO latency IO L B1 Configure IO latency IO L...

Page 50: ...sistors WR for B2 ODT WR C1 Configure the memory on die termination resistors WR for C1 ODT WR C2 Configure the memory on die termination resistors WR for C2 ODT WR D1 Configure the memory on die term...

Page 51: ...rmination resistors PARK for D2 ODT NOM A1 Use this to change ODT A1 Auto Manual settings The default is Auto ODT NOM A2 Use this to change ODT A2 Auto Manual settings The default is Auto ODT NOM B1 U...

Page 52: ...ted to system level Premote Warnings Determines if warnings are promoted to system level Halt on mem Training Error Enable Disable Halt on mem Training Error Memory Test Enable Disable memory test dur...

Page 53: ...alibration CPU Load Line Calibration helps prevent CPU voltage droop when the system is under heavy loading DRAM AB Voltage Configure the voltage for the DRAM on channel A B DRAM CD Voltage Configure...

Page 54: ...Adaptive Add voltage to the CPU Mesh when the system is under heavy loading Override The voltage is fixed CPU Mesh Voltage Offset Configure the voltage for the CPU Mesh Voltage Offset V Min 1 000V Ma...

Page 55: ...ise the threshold to trigger CPU over current protection and over voltage protection for better overclocking capabilities CPU Integrated VR Efficiency Mode Enable FIVR Efficiency Management for power...

Page 56: ...een In this section you may set the configurations for the following items CPU Configuration IIO Configuration Chipset Configuration Storage Configuration Super IO Configura tion Serial Port Console R...

Page 57: ...tes Support for power saving It is recommended to keep C3 C6 and C7 all enabled for better power saving CPU Thermal Throttling Enable CPU internal thermal control mechanisms to keep the CPU from overh...

Page 58: ...form to support trust decisions by end users DCU Streamer Prefetcher DCU streamer prefetcher is an L1 data cache prefetcher MSR 1A4h 2 Hardware Prefetcher Automatically prefetch data and code for the...

Page 59: ...C422 WSI IPMI X299 WSI IPMI 53 English 3 4 2 IIO Configuration PCIE4 This allows you to select PCIe port Bifuration for selected slots s...

Page 60: ...monitor better utilize hardware by improving application compatibility and reliability and provid ing additional levels of manageability security isolation and I O performance Primary Graphics Adapter...

Page 61: ...option enables or disables the ASPM support for all PCH downstream devices PCH DMI ASPM Support This option enables disables the ASPM support for all PCH DMI devices Restore AC Power Loss Select the...

Page 62: ...ive Press Ctrl I to enter RAID ROM during UEFI POST process SATA Aggressive Link Power Management Use this item to enable or disable SALP Hard Disk S M A R T Use this item to enable or disable the S M...

Page 63: ...Port 1 COM1 Serial Port Use this item to enable or disable the serial port Change Settings Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set paramet...

Page 64: ...ure Console Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Terminal Type Use this item to select the preferred terminal emulat...

Page 65: ...signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and...

Page 66: ...Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 tha...

Page 67: ...ed will controlled by BMC If Manual is selected configure the items below CPU_FAN1 This allows you to set the CPU fan1 s speed The default value is Smart Fan FRNT_FAN1 This allows you to set the front...

Page 68: ...art Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This allows you to set temperature for each stage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer The default value...

Page 69: ...C422 WSI IPMI X299 WSI IPMI 63 English 3 4 8 Intel ME Information Intel ME Information screen displays the Intel ME Configuration information such as Operational Firmware Version and Firmware State...

Page 70: ...o be waked up by onboard COM port modem Ring In signals RTC Alarm Power On Allow the system to be waked up by the real time clock alarm Set it to By OS to let it be handled by your operating system US...

Page 71: ...encounter USB compatibility issues it is recommended to disable legacy USB support Select UEFI Setup Only to support USB devices under the UEFI setup and Windows Linux operating systems only PS 2 Simu...

Page 72: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Page 73: ...s authority to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password User Password Set or change the password for the user account Users are unable to cha...

Page 74: ...this item to set the system boot order USB Device BBS Priorities This page will show only when system install USB Storage Fast Boot Fast Boot minimizes your computer s boot time In fast mode you may...

Page 75: ...stem boots up Please note that a buzzer is needed Full Screen Logo Enable to display the boot logo or disable to show normal POST messages AddOn ROM Display Enable AddOn ROM Display to see the AddOn R...

Page 76: ...y Select Do not launch to not execute both legacy and UEFI option ROM Launch Video OpROM Policy Select UEFI only to run those that support UEFI option ROM only Select Legacy only to run those that sup...

Page 77: ...default is Disabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy OCU1 Slot OpROM Use this item to select slot storage and Network Option ROM poli...

Page 78: ...specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces Inventory Support This will execute inventory functio...

Page 79: ...e event logging for error progress codes during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes U...

Page 80: ...you prefer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters...

Page 81: ...t and Yes Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios Event Log The options include Do Nothing and E...

Page 82: ...76 English View Smbios Event Log Press Enter to view the Smbios Event Log records All values changed here do not take effect until computer is restarted...

Page 83: ...following message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the fol...

Page 84: ...g The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear...

Page 85: ...re set to default settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no...

Page 86: ...battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to...

Page 87: ...pt or a copy of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Aut...

Reviews: