10
E N G L I S H
CH 7000
S e r i e s
Select the wanted heating power by pressing:
•
button 1 only (LED on) for 750W
•
button 2 only (LED on) for 1250W
•
buttons 1 and 2 at the same time (LEDs on) for 2000W
When the desired room temperature has been reached, the thermostat knob should be turned
slowly anti-clockwise until the thermostat is heard to click off and the light is seen to go out. After
this the heater will keep the air temperature in the room at the set temperature by switching on and
off automatically.
FAN OPERATION:
The fan is controlled by button 3. The fan can be turned on only with the thermostat knob at “+”
position. It is possible to use the fan when the heating resistors are on (LED on) to blow the hot air
into the room.
To blow fresh air into the room, turn off the heating resistors.
CH 7000 TURBO TIMER:
TERMOVENTILATORE CON TERMOSTATO, TIMER E VENTOLA
All the above instructions for model CH 7000 TURBO also apply to model CH 7000 TURBO TIMER.
This model is also fitted with a 24hr timer which has 48 segments around its circumference, each
segment being equivalent to 30 minutes of time. With the aid of this timer it is possible to preset
the time and duration of the desired period(s) in which the heater must operate in any 24 hr period.
TIMER OPERATION
The centre of the timer has a 3 position slide switch (I -
¸
- O).
•
In the central position (denoted by the clock symbol
¸
) the timer will switch the heater on and
off automatically following the programmed setting, (see setting the timer, below).
•
The position denoted by the “I”, is a timer override position. The timer will continue to run, but
button 2 for 1250W heating power
button 1 for 750W heating power
button 3 for fan
thermostat knob