26
E N G L I S H
ASPIRCOMFORT PRO X 460H
High
vibrations
Vibrating panels
Check the integrity of the unit panels
and profiles.
Check the correct closing of the unit
cover and the panel that covers the
electronic board.
Make sure there are no walls that can
transmit vibrations to the wall / floor /
false ceilings.
Imbalanced fan blades
Check the integrity of the blades.
Clean the fans.
Make sure the small metal blade
balancing clips are still on the fans.
Condensation leak
Clogged condensation discharge
Clean the condensate discharge.
The condensation does not flow from
the discharge duct to the collection
tray
Make sure that the unit is perfectly
level.
Check that the condensation discharge
connections are not clogged.
The appliance does not
switch on
No power supply
Check whether there is voltage in the
mains (by switching on a light bulb in
the house, for example).
Check that the exclusive
thermomagnetic switch protecting
the appliance has not tripped (if so,
reset it). If the problem recurs, contact
the Service Department immediately
and do not attempt to operate the
appliance.
The appliance does not
cool/heat sufficiently
Set temperature too high or too low
Check and correct the temperature
setting if necessary.
The air filter is clogged
Check the air filter and clean it if
necessary.
Check that there are no obstructions to
the flow of air inside or outside.
Remove anything that might obstruct
airflow.