Instructions for use and maintenance 

EN

return-valve must be mounted on the cold water 

supply pipe, in observance of the direction arrow 

stamped on its body, indicating the incoming water’s 

direction. Additional stopcocks must not be mounted 

between the safety return-valve and the water 

heater.

Exception

If  the  local  regulations  (norms) 

require  the  usage  of  another  protection  valve  or 

mechanism  (in  accordance  with  EN  1487  or  EN 

1489),  then  it  must  be  bought  additionally.  For 

mechanisms operating in accordance with EN 1487 

the announced operational pressure must be no 

more than 0.7 MPa. For other protection valves, the 

pressure at which they are calibrated must be 0.1 

MPa lower than the one marked on the appliance’s 

sign.  In  these  cases  the  safety  valve  which  the 

appliance is supplied with should not be used.

Attention

! The presence of other /old/ safety return-

valves may lead to a breakdown of your appliance 

and they must be removed.

Attention

Other  type  of  stopping  armature  is  not 

allowed  between  the  protection  return  valve  (the 

protective device) and the appliance.

Attention

! T

he attaching of the safety return-valve 

to  threads  longer  than  10  mm  is  not  allowed, 

otherwise this may damage the valve and poses 

danger for your appliance

.

Attention

With  appliances  for  vertical  assembly, 

the safety valve has to be connected to the ingoing 

pipe with the safety plastic panel of the appliance 

being taken off. After it has been assembled it should be in 

position as shown on Fig. 3 and fig.4

.

Attention

The safety valve and the pipe between the 

valve  and  the  water  heater  must  be  protected  from 

freezing. During hose draining - its free end must be 

always open to the atmosphere (not to be immersed). Make 

sure that the hose is also protected from freezing

.

Opening the cold-water stopcock of the water supply 

piping network and opening the hot-water stopcock 

of the water-mixing faucet carries out the filling of the 

water heater with water. After the filling is complete, 

a constant stream of water must begin to flow from 

the water-mixing faucet. Now you can close the hot 

water stopcock.

In the event you must empty the water heater, first 

you  must  cut  off  its  power  supply.  The  inflow  of 

water from the water mains must first be terminated 

and the hot water tap of the mixing-faucet must be 

opened. The water tap 7 (fig 4) must be opened to 

drain the water from water tank. If there is no such 

tap build in the pipe line, than the water can be drain 

directly from inlet pipe of water tank .In the event of 

removing the flange, the discharge of several liters 

of water, which remain in the water tank, is normal.

Attention

Measures  must  be  undertaken  to 

prevent  damage  from  discharging  water  during 

draining. In the event that the water mains piping, 

pressure exceeds the pressure stated on the appliance 

(outlined here above in s. II and on the appliance’s rating 

plate), it shall be necessary to mount a pressure-reducing 

valve;  otherwise  the  water  heater  shall  not  function 

correctly. The Manufacturer does not assume any liability 

for problems arising out of the appliance’s improper use.

3. 

Water heater connection to the electrical

network (Fig.2)

Explanations to Fig. 2: 
TS - thermal switch; TR - thermal regulator;  R - 

heater; IL - light indicator; F - flange.

Attention

! Make sure the appliance is full of water 

prior to switching on the electrical mains power.

3.1. 

Models with power cord with a plug

 are 

connected by inserting the plug into a contact. They 

are switched off the power supply by drawing the 

plug out of the contact.

Attention

!  The  wall-plug  must  be  properly 

connected to a separate electrical circle that is 

provided with a protector. It must be earthed.

3.2. 

Models without power cord

The appliance has to be connected to a separate 

electricity circuit of the stationary electrical wiring. 

The circuit has to be supplied with a safety fuse 

16A (20A for power > 3700W). Copper single core 

(rigid – non stranded) conductor shall be used for 

the connection – cable 3 x 2.5 mm² (cable 3 x 2.5 

mm² for power > 3700W).

The electrical circuit supplying the appliance must 

have an in-built device ensuring the splitting of all 

terminal poles under conditions of super-voltage of 

category III.
To install the power supply wire to the appliance, 

remove the plastic cover (Fig.3). 
Connect the power wires in compliance with the 

marks on the terminals, as follows:

the phase - to mark A, A1, L or L1;

the neutral - to N (B or B1 or N1)

The safety wire must be obligatory connected to the 

screw joint marked with  .
After the installation, put the plastic cover back in 

its place!

Note: 

For  models  with  externally  adjustable 

thermostat  (shown  on  Fig.  3),  dismount  the 

handle  before  mounting  the  cover  by  pressing  it 

from the internal side till it gets detached from the 

plastic  cover.  Mount  the  plastic  cover  again, 

afterwards set the handle on its place by pressing it 

to click in.

Summary of Contents for ATE050

Page 1: ...r use and maintenance ES TERMO DE AGUA ELÉCTRICO 08 12 Instrucciones de uso y mantenimiento Read this manual carefully and keep it for future reference Lea atentamente este manual y guárdelo para futuras consultas ATE30S ATE50S ATE80S ATE050 ATE080 ...

Page 2: ......

Page 3: ...putting into operation must be carried out by certified electricians and technical personnel certified in installation of this category of appliances who have obtained their license in the state where the installation and commissioning of the appliance are carried out and in compliance with its local legislation Allalterationsandmodificationstothewaterheater sconstructionandelectricalcircuitryaref...

Page 4: ...res should be taken to lead and collect the leakages in order to prevent damages 7 If the probability exists for the premise s temperature to fall below 0 С the water heater must be drained In the event you must empty the water heater first you must cut off its power supply The inflow of water from the water mains must first be terminated and the hot water tap of the mixing faucet must be opened T...

Page 5: ...r mains pressure in excess of the acceptable pressure stated for the appliance IV MOUNTING AND SWITCHING ON Attention Improper installation and connection of the appliance may make it hazardous for the health and life of consumers It may cause grievous and permanent consequences including but not limited to physical injuries and or death Improper installation and connection of the appliance may al...

Page 6: ...ap 7 fig 4 must be opened to drain the water from water tank If there is no such tap build in the pipe line than the water can be drain directly from inlet pipe of water tank In the event of removing the flange the discharge of several liters of water which remain in the water tank is normal Attention Measures must be undertaken to prevent damage from discharging water during draining In the event...

Page 7: ...al use of the heater under the influence of high temperature lime scale the so called lime scale layer is deposited upon the heating element s surface This worsens the heat exchange between the heating element and water The heating element s surface temperature increases along of boiling water The thermoregulator begins to switch on and off more frequently A deceptive activation of the thermal pro...

Page 8: ...ón la conexión a la red de agua y a la red eléctrica así como la puesta en marcha deberán ser llevadas a cabo únicamente por electricistas y técnicos cualificados para la reparación y el montaje del equipo que han adquirido sus competencias profesionales en el territorio del país donde se lleva a cabo el montaje y la puesta en marcha del equipo y en conformidad con su normativa Queda terminantemen...

Page 9: ...de calentamiento del agua es habitual que gotee agua a traves de la abertura de drenaje de la válvula de seguridad La válvula de seguridad debe estar abierta a la atmósfera Además deben tomarse medidas para conducir y recoger las fugas a fin de evitar danos 7 Si se preve que se van a alcanzar temperaturas de congelación bajo С el termo debe ser completamente vaciado En el caso de que necesite vaci...

Page 10: ...ión aumenta al aumentar la temperatura mediante liberación del exceso de presión durante la apertura del drenaje La válvula de protección antiretorno no puede proteger el aparato cuando el flujo de agua viene a una presión mayor que la determinada para el aparato IV MONTAJE Y CONEXIÓN ATENCION La instalación y conexión incorrecta del equipo podrán hacerlo peligroso para la salud y la vida de los u...

Page 11: ...rese de que la manguera también está protegida contra la congelación La apertura de la llave de agua fria de la red de suministro de agua y la apertura de la llave de agua caliente del grifo de mezcla lleva a cabo el llenado del termo de agua Tras el completo llenado del termo debe comenzar un flujo constante de agua desde el grifo de mezcla de agua Ahora ya puede cerrar el grifo de agua caliente ...

Page 12: ... problema VII MANTENIMIENTO PERIÓDICO En caso de función normal del calentador bajo la influencia de la alta temperatura de la superficie del calentador se difiere caliza o sea piedra de caldera Esto empeora el cambio de calor entre el calentador y el agua La temperatura de la superficie del calentador y en la zona alrededor de éste aumenta Se oye un ruido típico de agua hirviente El regulador de ...

Page 13: ...ción es una imagen de referencia su aparato podría diferir B E C H H1 G D 100 125 max 310 mm min 220 mm max max min min Type D mm H mm H1 mm B mm E mm ATE30S 353 555 500 380 167 ATE50S 386 803 748 426 172 ATE80S 386 1205 1150 426 172 ATE050 440 589 538 465 182 ATE080 440 839 788 465 182 ...

Page 14: ...1 220 mm 310 mm min 100 mm min 100 mm min 100 mm min 700 mm min 300 mm V1 V3 0 60 m 0 60 m V3 2 25 V2 0 60 m V0 V3 X X V1 V3 0 60 m 0 60 m V3 2 25 V2 V0 0 60 m ...

Page 15: ...2 3 4 Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir TR TS IL R supply cord PZ2 H O 2 H O 2 A ...

Page 16: ...de teléfono 96 324 67 51 96 324 67 52 Email avisos servictecnica es Horario 9 00 to 14 00h 16 00 to 19 00h SERVITECNICA Address C Ciudad de Cartagena nº 20 Phone 96 324 67 51 96 324 67 52 Email avisos servictecnica es Schedule 9 00 to 14 00h 16 00 to 19 00h www aspes es ...

Reviews: