background image

14

ASP Portable Barcode Reader

Technical Information

Wand Connector Signals

The wand connector used on all ASP Barcode Readers is a 9 pin male sub-

miniature D connector suitable for use with the ASP WAND/2000.  The pinout

of the wand connector is shown below:

Pin

Function

2

Digital Wand Input

7

Ground

9

+5v to Wand

RS-232 Connector Signals

The RS-232 connector used on all ASP Barcode Readers is a 9 pin female sub-

miniature D connector, the pinout of which is shown below:

Pin

Function

1

Not Connected

2

Data out from the BCR to the computer

3

Not Connected

4

CTS handshaking signal (to the BCR)

5

GROUND

6

Not Connected

7

Not Connected

8

RS-232 input from video terminal

9

Combined serial output (pins 2 + 8)

RS-232 Handshaking

The video terminal or computer to which the Portable BCR is connected may

not be able to accept data at all times.  The Portable BCR always checks the

CTS signal (Clear To Send, pin 4) before sending any data, and if the CTS

signal is turned off, the BCR will not transmit the data.
Since this may cause problems with some applications, the CTS signal is

normally disabled with a jumper inside the Home Base.  If your application

requires the use of the CTS signal, this jumper should be removed.

Summary of Contents for Portable BCR

Page 1: ...7600 FAX 03 9578 7727 email solutions asp com au World Wide Web http www asp com au ASP Microcomputers is a division of Grayline Holdings Pty Ltd ACN 004 940 729 Manual revised May 26th 1998 Copyrigh...

Page 2: ......

Page 3: ...g Up Your Portable Barcode Reader 8 Operation with the IBM PC XT AT or PS 2 9 RS 232 Operation 9 IBM PC XT Keyboard Scan Code Output Mode 9 Configuration Functions 10 Test and Diagnostic Functions 13...

Page 4: ......

Page 5: ...automatically recharges the Portable BCR s built in batteries when connected To conserve power a wand with a push to read switch is supplied the small button on the wand must be pressed before scannin...

Page 6: ...the unit beeps and self tests it displays a on the screen when ready Start scanning barcodes or entering data on the keyboard When you first receive your Portable BCR the rechargeable batteries conta...

Page 7: ...o back and not from side to side When scanning a barcode symbol you should move your hand and forearm in the direction of the scan without twisting your wrist This will prevent the barcode wand from t...

Page 8: ...n a flat surface Avoid using poor quality labels or inappropriate types of barcodes If in doubt discuss this with your dealer Guard against barcode damage such as Liquid spills on the barcode symbol c...

Page 9: ...he functions described starting on page 10 of this manual If the FUNC key is pressed during normal keypad entry or pressed again when the Function prompt is being displayed as above an ASCII code prom...

Page 10: ...ay be deleted by using the backspace key Once ENTER has been pressed the line just typed cannot be edited Editing data on a two line display is impractical Accordingly we suggest you adopt a method of...

Page 11: ...ably flat and the unit should be recharged properly before further use The Portable BCR automatically performs self checking and should beep when turned on If yours doesn t you should check all plugs...

Page 12: ...not You can press the YES key to select an emulation the NO key to turn an emulation off or the ENTER key to keep the present setting The key will step back one question if you mistakenly press an in...

Page 13: ...s if you entered it on the keyboard Whenever the Portable BCR is plugged into the Home Base and the Home Base s plug pack is connected to mains power the Portable BCR s will be charged the green indic...

Page 14: ...neous options output terminator None CR CR LF or TAB reverse shift mode RS 232 echo Keypress echo and beeper loudness Reverse shift mode is used with IBM PC type computers where the keyboard is operat...

Page 15: ...n 11 download If set to zero the string EOF will be sent if set to 255 no end of file indication will be output The Scan Delay which is set in tenths of a second and can be set to 0 to 255 ie 0 to 25...

Page 16: ...number of scans since storage memory was last erased 24 Displays the number of data records stored in memory 25 Allows a barcode template to be set which is used to strictly define a valid barcode sy...

Page 17: ...in 32 Restarts a loaded custom program 50 Downloads storage memory to computer 50 lines at a time The number of lines downloaded at a time can be changed with Function 59 59 Sets the number of lines d...

Page 18: ...ata out from the BCR to the computer 3 Not Connected 4 CTS handshaking signal to the BCR 5 GROUND 6 Not Connected 7 Not Connected 8 RS 232 input from video terminal 9 Combined serial output pins 2 8 R...

Page 19: ...ial combining circuit which allows input to the computer to come from either the Portable BCR or the video terminal A suitable Y cable is available from ASP or your dealer or can be made as described...

Page 20: ...ed to a problem computer via an RS 232 port Full documentation of the ASPKey driver is provided when you purchase ASPKey but cable details are provided below for completeness PC with D25 Male Serial P...

Page 21: ...c barcode Code 128 consists of 106 different printed characters with each character having three possible meanings depending on which of three different character sets is in use EAN 128 is a specialis...

Page 22: ...j 011 VT K 043 075 K 107 k 012 FF L 044 076 L 108 l 013 CR M 045 077 M 109 m 014 SO N 046 078 N 110 n 015 SI O 047 079 O 111 o 016 DLE P 048 0 080 P 112 p 017 DC1 Q 049 1 081 Q 113 q 018 DC2 R 050 2 0...

Page 23: ...e Base and for a period of one year from the date of purchase in respect of the ASP Wand and battery pack To the extent permitted by law ASP s liability to users of the programming language is limited...