ASO Safety Solutions Sentir Safety Contact Bumper Instruction Manual Download Page 6

INSTRUCTION MANUAL

Safety Contact Bumper

5  Technical data

Actuati ng forces:

   

< 150 N by test specimen Ø80 mm (according to DIN EN ISO 13856-3)

   

 

 

< 400 N by test specimen 45x400 mm (according to DIN EN ISO 13856-3)

Inacti ve edge region:

 

0 mm

Angle of acti vati on:

  

± 45° 

Dwitching cycles:

   

> 10 000

Electric  capacity:

   

24 v 10 mA

Protecti on class:

   

IP 54 (higher protecti on class on request)

Temperature range:

  

± 0 bis +55°C

Connecti on cable:

   

Pluggable, 2 x 0,34 mm² ( PUR black) mit M8 connector, 0,12m

Maintenance:

 

 

The Bumper is maintenance-free. Annual service is recommended.

Certi fi cati on:

 

 

EN ISO 13856-3

   

 

 

EN ISO 13849-1

   

 

 

EN 12978

   

 

 

UL 508

5.1  Dimensioning of bumper height

Use the following key in order to determine the appropriate height for the bumper:

Actuati ng distance:   

 

sB =  15 % bumper height

Overtravel distance: 

  

sV =  60 % bumper height

No longer compressible bumper: 

25 % bumper height

The overtravel distance sV can then be used to determine the appropriate bumper height.    

 

 

Average values by a test speed of 10 mm/s.

These data are reference values compiled by laboratory tests. Even if the component is used as intended, external factors 

and reacti on ti mes of all system components can have an infl uence on this type of value. Taking into account a risk analysis 

of the machine to be carried out, the applicati on of this safety component thus allows a presumpti on of conformity, but 

does not release the machine manufacturer from the obligati on to carry out an applicati on-side test in order to demonstrate 

compliance with all applicable standards and directi ves.

F

F

Actuati ng distance

Overtravel distance

No longer

compressible

1. No safety functi ons have been evaluated by UL 

2. These products were only investi gated for risk of fi re and electrical shock (in accordance with UL508) 

Summary of Contents for Sentir Safety Contact Bumper

Page 1: ...INSTRUCTION MANUAL Safety Contact Bumper U S Edition ASO GmhH All Rights Reserved ...

Page 2: ...mponents Composants supplémentaires Componenti ausiliari Bijkomende componenten Funktionsprüfung Functional test Contrôle de fonction Controllo funzionale Functiecontrole Sicherheitssensoren reagieren auf Betätigung Safety sensor response to actuation Le senseur de sécurité réagit à l actionnement Il sensore di sicurezza reagisce all azionamento Veiligheidssensor reageert op activering Sicherheits...

Page 3: ...umper is not damaged After mounting a functioning test should be made 2 The construction The basic construction of the safety contact bumper consists out of a foam core and a one piece extruded signal generator sensor with two contact elements located opposite each other which are assembled on an aluminium profile The coating of the SENTIR bumper consists of imiation leather When the SENTIR bumper...

Page 4: ...er can be made to customers specifications in various shapes colors and sizes 3 1 Standard delivery Length min 150mm max 3000mm Connections The cable exit with each 0 12m Length 1x M8 connector male 1xM8 connector female condition at the ends of the bumpers The standard delivery package contains an extension cable in accordance with model code Colors Black Yellow Black Yellow striped available for...

Page 5: ...e g 60 mm 3 Height e g 100 mm 4 Materials L Artificial leather 5 Cable versions 4 0 M8 connector male and 1 x M8 connector female 4 2 like 4 0 with M8 connection cable 2 5m 4 3 like 4 0 with 5m cable M8 connector female and M8 resistor plug 4 4 like 4 0 with 5m cable M8 connector male and 5m cable M8 connector female 6 Length e g L 2 5 m ...

Page 6: ... distance sV 60 bumper height No longer compressible bumper 25 bumper height The overtravel distance sV can then be used to determine the appropriate bumper height Average values by a test speed of 10 mm s These data are reference values compiled by laboratory tests Even if the component is used as intended external factors and reaction times of all system components can have an influence on this t...

Page 7: ...l applications have to be tested directly at the actual application 5 3 The signal processing Evaluation electronic Relay output Supply voltage Terminal resistor 8 2 kΩ To avoid the risk of crushing Safety gloves must be worn Please pay a ention to The SENTIR bumper is equipped with two two core cables which allow for series connection The maximum number of connected bumpers is 5 and the total len...

Page 8: ...ce on the mounting plate If the bumper is supposed to be connected to another bumper a further cable entry has to be drilled In order to prevent damage of the connection cable each cable entry has to be deburred carefully and provided with a protection sleeve 3 Lead the connection cable s through the protection sleeve s and slide the bumper onto the mounting plate up to the stop 4 When everything ...

Page 9: ...ly and dont t pull on the wires Place the SENTIR bumpers in the planned positions with the connecting wires at the outer limits of the detection zone The control unit should be installed as supplied It must not be modified or subjected to procedures or connections other than those described with the instructions MOUNTING INFORMATION 9 Preparations set up To avoid the risk of crushing Safety gloves...

Page 10: ...tion failure as well as a risk of injury Test the SENTIR bumper operations If the inspection tests are performed and reveal any problems do not allow the use of the machine until they are rectified Record the inspection and test in a written log Thorough Examination and test Recommended twice yearly or after damage To be done by a person trained or qualified in electrical and mechanical engineerin...

Page 11: ...can be damaged by impacts from sharp or heavy objects After every such event the SENTIR bumper should be inspected for deformation cracks or puncturing and replaced if necessary The SENTIR bumpers have been designed and tested to withstand 10 000 activations in any one spot In use this number of operations in a single location should not be exceeded Occasional heavy loads are unlikely to damage th...

Page 12: ...Rev 01 Subject to technical modifications No liability can be assumed for errors or misprints ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 NJ 07866 Rockaway T 1 973 5869600 F 1 973 5861590 www asosafety com E Mail aso us asosafety com ...

Reviews: