10 Maintenance:

To avoid the risk of crushing while maintaining, Safety gloves must be worn!

Installati on and electrical work must be performed by authorized electricians.

• 

Weekly check whether fl uids have collected around the SENTIR bumpers, possibly indicati ng fl uids underneath the SENTIR 

bumpers as well.

• 

The SENTIR bumpers should be regularly swept to prevent potenti al hazards. If it is necessary to wash or hose down the 

SENTIR bumpers to clean or remove grease etc., warm water and detergent may be used.

• 

Do no use solvents to clean SENTIR bumpers.

Routi ne Inspecti on and tests:

• 

Recommended weekly.

• 

Stop the machine, clean the SENTIR bumpers and allow them to dry off . Inspect the surface of the SENTIR bumper for 

damage.

• 

Damage which exposes the foam must be dealt with immediately. Check that the surface are not cracked or broken.  

Damaged parts must be replaced immediately. 

Otherwise there is a risk of functi on failure, as well as a risk of injury.

• 

Test the SENTIR bumper operati ons.

• 

If the inspecti on tests are performed and reveal any problems, do not allow the use of the machine unti l they are recti fi ed. 

Record the inspecti on and test in a writt en log.

Thorough Examinati on and test:

Recommended twice yearly or aft er damage. To be done by a person trained or qualifi ed in electrical and mechanical 

engineering.

• 

Isolate power source to the machine. Observe electrical safety precauti ons.

• 

Disconnect the SENTIR bumper from the control unit.

• 

Inspect the SENTIR bumper components thoroughly for mechanical damage.

• 

Test the SENTIR bumper operati ons.

 

   

Read all instructi ons fi rst before installing/se�  ng up the Product!

 

   

Do not drink any alcohol or take any drugs before or during the setup of the Product and 

 

   

follow the safety instructi ons carefully.

8k2 Ω

reverse polarity 

protecti on

1 (brown)

2 (blue)

4 (brown)

3 (blue)

ELMON rail 41-822

terminal „X1“

terminal „X2“

terminal „X3“

terminal „X4“

1. ASO 8k2

2. 4-wire

fi g. 13

fi g. 12

13 Electrical connecti on

Summary of Contents for Sentir Safety Contact Bumper

Page 1: ...INSTRUCTION MANUAL Safety Contact Bumper U S Edition ASO GmhH All Rights Reserved ...

Page 2: ...mponents Composants supplémentaires Componenti ausiliari Bijkomende componenten Funktionsprüfung Functional test Contrôle de fonction Controllo funzionale Functiecontrole Sicherheitssensoren reagieren auf Betätigung Safety sensor response to actuation Le senseur de sécurité réagit à l actionnement Il sensore di sicurezza reagisce all azionamento Veiligheidssensor reageert op activering Sicherheits...

Page 3: ...umper is not damaged After mounting a functioning test should be made 2 The construction The basic construction of the safety contact bumper consists out of a foam core and a one piece extruded signal generator sensor with two contact elements located opposite each other which are assembled on an aluminium profile The coating of the SENTIR bumper consists of imiation leather When the SENTIR bumper...

Page 4: ...er can be made to customers specifications in various shapes colors and sizes 3 1 Standard delivery Length min 150mm max 3000mm Connections The cable exit with each 0 12m Length 1x M8 connector male 1xM8 connector female condition at the ends of the bumpers The standard delivery package contains an extension cable in accordance with model code Colors Black Yellow Black Yellow striped available for...

Page 5: ...e g 60 mm 3 Height e g 100 mm 4 Materials L Artificial leather 5 Cable versions 4 0 M8 connector male and 1 x M8 connector female 4 2 like 4 0 with M8 connection cable 2 5m 4 3 like 4 0 with 5m cable M8 connector female and M8 resistor plug 4 4 like 4 0 with 5m cable M8 connector male and 5m cable M8 connector female 6 Length e g L 2 5 m ...

Page 6: ... distance sV 60 bumper height No longer compressible bumper 25 bumper height The overtravel distance sV can then be used to determine the appropriate bumper height Average values by a test speed of 10 mm s These data are reference values compiled by laboratory tests Even if the component is used as intended external factors and reaction times of all system components can have an influence on this t...

Page 7: ...l applications have to be tested directly at the actual application 5 3 The signal processing Evaluation electronic Relay output Supply voltage Terminal resistor 8 2 kΩ To avoid the risk of crushing Safety gloves must be worn Please pay a ention to The SENTIR bumper is equipped with two two core cables which allow for series connection The maximum number of connected bumpers is 5 and the total len...

Page 8: ...ce on the mounting plate If the bumper is supposed to be connected to another bumper a further cable entry has to be drilled In order to prevent damage of the connection cable each cable entry has to be deburred carefully and provided with a protection sleeve 3 Lead the connection cable s through the protection sleeve s and slide the bumper onto the mounting plate up to the stop 4 When everything ...

Page 9: ...ly and dont t pull on the wires Place the SENTIR bumpers in the planned positions with the connecting wires at the outer limits of the detection zone The control unit should be installed as supplied It must not be modified or subjected to procedures or connections other than those described with the instructions MOUNTING INFORMATION 9 Preparations set up To avoid the risk of crushing Safety gloves...

Page 10: ...tion failure as well as a risk of injury Test the SENTIR bumper operations If the inspection tests are performed and reveal any problems do not allow the use of the machine until they are rectified Record the inspection and test in a written log Thorough Examination and test Recommended twice yearly or after damage To be done by a person trained or qualified in electrical and mechanical engineerin...

Page 11: ...can be damaged by impacts from sharp or heavy objects After every such event the SENTIR bumper should be inspected for deformation cracks or puncturing and replaced if necessary The SENTIR bumpers have been designed and tested to withstand 10 000 activations in any one spot In use this number of operations in a single location should not be exceeded Occasional heavy loads are unlikely to damage th...

Page 12: ...Rev 01 Subject to technical modifications No liability can be assumed for errors or misprints ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 NJ 07866 Rockaway T 1 973 5869600 F 1 973 5861590 www asosafety com E Mail aso us asosafety com ...

Reviews: