ASO Safety Solutions SENTIR edge 25.45 CT Product Information Download Page 12

PRODUCT INFORMATION

Warnings and disclaimers

1. Preparations / set up

All SENTIR edges are inspected and tested before being shipped to ensure against damage. If the shipping container appears 
to be damaged, please notify the supplier immediately.

WARNING:

 Do not bend or fold as damage may occur.

2. Handling / Storage

To avoid the risk of crushing, Safety gloves must be worn!

Recommended:

- Ideal storage and temperature -25C to 75C (or if different per edge)

- Ideal storage: Dry, clean and fl at

- Transport SENTIR edges in the supplied packaging to where they are to be installed.

Not Recommended:

- Signifi cant bending of SENTIR edges

- Storing SENTIR edges vertically

- Extreme temperature fl uctuations

- Outdoor storage
- Pulling SENTIR edges by the cable
- Stack up SENTIR edges without packaging

3. Maintenance

- If damage occurs, such as brittle or torn rubber profi le, non-tight switching chamber, insuffi cient contact resistance in  

the activated state or similar, the SENTIR edge must be replaced immediately.

- During the maintenance operations, disconnect the machine’s prime mover before working in the SENTIR edge system.  

Observe all applicable electrical safety precautions.

- Cleaning: The profi les should be kept clean of deposits such as swarf (fi ne metallic fi llings or shavings removed by   cut-

ting, grinding or any other mechanical process), debris, and other foreign materials to prevent damage or   dead-zones. It 

is permissible to use warm water and a mild detergent to clean the surface of the area.

- Important: Do not use solvents

- Stop the machine, clean the profi les and allow them to dry off. Inspect the surface of the profi le for the damage.  

Any damage that punctures the profi le could let material or liquid in. It must be dealt with immediately. Check that all  

endcaps, corners and joints are secure and free from damage. Damaged parts must be replaced immediately.

- Test the profi le operation. If these checks reveal any problem, do not allow use of the machine until the problems are recti-

fi ed.

To avoid the risk of crushing, Safety gloves must be worn!

Installa� on and electrical work must be performed by authorized electricians.

12

13

Summary of Contents for SENTIR edge 25.45 CT

Page 1: ...Product Information US Edition 25 45 ASO Inc All Rights Reserved C 25 45 ...

Page 2: ...5 CT SENTIR edge 25 45 TTLa SENTIR edge 25 45 TTLL edge 25 45 Ts T La SENTIR ASO Safety contact edges Profile width Profile height Sealing lip La Single sided outwards LL Double sided outwards Material Base shape T T base Ts T base small CT Clips base 2 ...

Page 3: ...H Zertifizierungen Certificates EN ISO 13856 2 EN 12978 EN ISO 13849 1 UL 325 SENTIR edge 25 45 CT SENTIR edge 25 45 T s TLa SENTIR edge 25 45 FTLa 3 71 5 50 8 25 Specifications All shown variants are also availiable with smaller base shape Ts Dimension in mm Tolerances according to DIN ISO 3302 1 class E2 3 ...

Page 4: ... distance c 7 7 mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The re...

Page 5: ... mm Overtravel distance d to 250 N 19 9 mm Overtravel distance f to 400 N 22 7 mm Overtravel distance h c to 600 N 24 8 mm Test Speed 100 mm s Actuation Force FA 60 4 N Actuation distance c 10 0 mm Overtravel distance d to 250 N 19 8 mm Overtravel distance f to 400 N 22 6 mm Overtravel distance h c to 600 N 24 5 mm Test Speed 200 mm s Characteristics for test temperature 20 C The response time of ...

Page 6: ...tuation distance c 10 8 mm Overtravel distance d to 250 N 22 8 mm Overtravel distance f to 400 N 26 2 mm Overtravel distance h c to 600 N 28 7 mm Test Speed 100 mm s Actuation Force FA 60 6 N Actuation distance c 11 3 mm Overtravel distance d to 250 N 22 3 mm Overtravel distance f to 400 N 26 0 mm Overtravel distance h c to 600 N 28 6 mm Test Speed 200 mm s Characteristics for test temperature 20 ...

Page 7: ...EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C 50 150 250 350 450 550 0 5 10 15 20 25 30 35 40 45 A B1 B2 c d e f g h s mm F N C Tested according DIN EN ISO 13856 2 Test Unit round 80mm Actuating Point C3 Temp 20 C...

Page 8: ...emical resistance Water dist 1 Dilutes acid 1 Dilutes base 1 Not oxidizing acids 2 Oxidizing acids 2 ASTM oil No 3 6 Mineral oil 2 Brake fluid 2 3 Antifreezing admixture 1 Gasoline 5 Diesel 2 3 Alcohol 1 1 no effects Permanent contact 2 few effects Some contact 3 medium effects Some contact 4 noticeable effects Reduced contact 5 severve effects Very brief contact 6 extreme effects Avoid contact 1 v...

Page 9: ...lip Contact plug KS 4 with sealing Aluminium fixation profile Double chamber profile with integrated switching chamber Lock cap End cap KS 4 W or L XX Xm 25 45 Set 1x KS 4 plug with lock cap resistor 8 2 kOhm or XX X m cable 1x End cap 25 45 2x Fixation clip 9 ...

Page 10: ...the plug fits closely to the lock cap 5 Put on end caps Put on end cap onto the edge and fasten it while pushing fixation clip into the given space until it clicks into place For bigger contact edges an additional fixation clip is used to fasten the end cap within the profile 6 Electrical testing of the safety contact edge Measure the contact edge with a multimeter In rest position the resistance valu...

Page 11: ...n the complete c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the contact edge and should be avoided at all costs 7 Safety contact edges with collateral c bases at first have to be clipsed with one side into the aluminum profile Then press in the other c base Pulling or pushing the safety contact edge into the aluminum profile can cause damage to the co...

Page 12: ...dge must be replaced immediately During the maintenance operations disconnect the machine s prime mover before working in the SENTIR edge system Observe all applicable electrical safety precautions Cleaning The profiles should be kept clean of deposits such as swarf fine metallic fillings or shavings removed by cut ting grinding or any other mechanical process debris and other foreign materials to pr...

Page 13: ... Always adhere to the local and national electrical code specifications when wiring SENTIR edge and other controls Wire the SENTIR edge into controls as specified by the control manufacturer The safety regulations issued by the Trade Association and those for electrical installation must be considered Failure to comply with the safety regulations may result in severe or fatal injury or serious damag...

Page 14: ...ion contained in this operating instructions manual is provided without liability and is subject to technical modi fications There are no residual risks provided that the safety instructions as well as the instructions regarding mounting commissioning operation and maintenance are observed Exclusion of Liability The manufacturer shall accept no liability for damages and malfunctions resulting from ...

Page 15: ...Declaration of conformity 15 ...

Page 16: ...PRODUCT INFORMATION Notes 16 ...

Page 17: ...Notes 17 ...

Page 18: ...3 299 www asosafety de aso eu asosafety com Headquarter USA ASO Safety Solutions Inc 300 Roundhill Drive Unit 6 Rockaway NJ 07866 Phone 1 973 7844994 Fax 1 973 5861590 www asosafety com sales us asosafety com 15 DB 13 014 Technical data rev 04 as of December 10th 2019 Technical changes reserved ...

Reviews: