18
18
English
ELMON rail 37-726 / ELMON rail 38-726
Safety Relay
Version
ELMON rail 37-726 ELMON rail 38-726
Safety-related inputs
2x
2x
Safety-related outputs
1x
2x
(2nd contact internally
bridged to +24 V)
Auxiliary outputs
1x
2x
5. Application examples
Circuit diagram in zero-potential state. Sensor not actuated.
The auxiliary relay output is used for visualising the switching state of the safety contact edge.
5.1 Example of use
ELMON rail 37-726
Safety-related monitoring of two sensor
circuits for bringing a drive with automatic
restart to a standstill with an ELMON rail
37-726. The auxiliary output is connected
to the PLC controller of the plant (e.g. for
visualisation).
5.2 Example of use
ELMON rail 38-726
Safety related monitoring of two sensor
circuits with start release via start button
with one channel of an ELMON rail 38-726.
For functional test of the forcibly actuated
contactor K1, its normally closed contacts
are connected to the start circuit (Z1 Z2).
6. Device overview
6.1 Versions
Housing, 22.5 mm wide, made of polyamide for 35 mm DIN rail mounting acc. to EN 60715.